RTE 1401 Exam – Questions With Appropriate
Solutions
Add to calendar
Play your way to mastery with fun games
Match Blocks Charms NEW
Practice questions for this set
Learn 1 /7 Study with Learn
Hospital Information System
Choose an answer
What are the two digital receptor
1 2 What does HIS stand for?
types
The electronic signal from the
3 photodetector is then passed through 4 What is the disadvantage of the DR
the _______ where it is digitized
, Don't know?
Terms in this set (67)
What are the two digital receptor -computed radiography (CR)
types -direct radigraphy
Computed radiography (CR) systems that use storage phosphors to temporarily
store energy representing the image signal
-uses cassettes
-more senisitve to radiation
Direct radiography (DR) systems that have detectors that directly capture
and read out an electronic image signal
-flat pannel detector permentally in wall or table
bucky
What are the primary parts of a -cassette
cassette based system -photostimuable phosphor plate (PSP)
-plate readers
-computer workstation
What is the disadvantage of the DR if one CCD goes out show up as missing tile on
image
Can you change between indirect not, you can not change between them
and direct DR systems?
Direct DR system does what to increases patient dose
patient dose?
Histogram a graphic representation of the data set
-expected pixel in values
Solutions
Add to calendar
Play your way to mastery with fun games
Match Blocks Charms NEW
Practice questions for this set
Learn 1 /7 Study with Learn
Hospital Information System
Choose an answer
What are the two digital receptor
1 2 What does HIS stand for?
types
The electronic signal from the
3 photodetector is then passed through 4 What is the disadvantage of the DR
the _______ where it is digitized
, Don't know?
Terms in this set (67)
What are the two digital receptor -computed radiography (CR)
types -direct radigraphy
Computed radiography (CR) systems that use storage phosphors to temporarily
store energy representing the image signal
-uses cassettes
-more senisitve to radiation
Direct radiography (DR) systems that have detectors that directly capture
and read out an electronic image signal
-flat pannel detector permentally in wall or table
bucky
What are the primary parts of a -cassette
cassette based system -photostimuable phosphor plate (PSP)
-plate readers
-computer workstation
What is the disadvantage of the DR if one CCD goes out show up as missing tile on
image
Can you change between indirect not, you can not change between them
and direct DR systems?
Direct DR system does what to increases patient dose
patient dose?
Histogram a graphic representation of the data set
-expected pixel in values