FDNY S12 GUARANTEED PASS!!
Unlawful to be installed - (ANSWER)Devices that give the physical appearance of fire
protection equipment (ex. CCTV sprinkler head)
Minimum amount of time records must be kept - (ANSWER)3 years
Hydro static test must be performed - (ANSWER)Every 5 years
System fully out of service - (ANSWER)Tag/red Disc/White
System partially out of service - (ANSWER)Tag/Red. Disc/Blue
System free from defects - (ANSWER)Tag/Green. Disc/N/A
S12/S15 holder may perform - (ANSWER)Visual inspections, proper notifications and record
inspection results
S12/S15 with Q99/01 May perform - (ANSWER)Visual inspections, test notification appliances,
perform daily and weekly routine maintenance and record inspection results
MFSPC - (ANSWER)Master fire suppression piping contractor
MP - (ANSWER)Master plumber
MFSPC w/s12/15 can - (ANSWER)Inspect, test, maintain and repair/replace system components
MP with S12/15 can only work on - (ANSWER)Residential with 30 sprinkler heads or less and
no booster pump
Page 1 of 5
, Deluge system - (ANSWER)All sprinkler heads are open, pipes dry
ELO extra large orifice sprinkler - (ANSWER)Orifice size greater than 1"
Extended coverage sprinklers head - (ANSWER)Covers max 400sqft in light hazard and 144sqft
for high hazard areas
Large orifice sprinkler - (ANSWER)Orifice greater than 3/4" but smaller than 1"
RTI - (ANSWER)Response time index
SIN - (ANSWER)Sprinkler identification numbers required on sprinkler heads manufactured
after 1/1/2000
Minimum maintained building temperature - (ANSWER)40deg F
System where water is stored in pipes. - (ANSWER)Automatic wet system
System where air is stored in pipes - (ANSWER)Automatic Dry system
Psi in dry system piping - (ANSWER)15-20psi
Has no water in pipes until fire/smoke is detected - (ANSWER)Pre action system
Who needs to draw sketch of compactor garbage Shute sprinkler system - (ANSWER)CoF
holder
_____________ sprinkler heads have been recalled - (ANSWER)Cycling sprinkler heads
Page 2 of 5
Unlawful to be installed - (ANSWER)Devices that give the physical appearance of fire
protection equipment (ex. CCTV sprinkler head)
Minimum amount of time records must be kept - (ANSWER)3 years
Hydro static test must be performed - (ANSWER)Every 5 years
System fully out of service - (ANSWER)Tag/red Disc/White
System partially out of service - (ANSWER)Tag/Red. Disc/Blue
System free from defects - (ANSWER)Tag/Green. Disc/N/A
S12/S15 holder may perform - (ANSWER)Visual inspections, proper notifications and record
inspection results
S12/S15 with Q99/01 May perform - (ANSWER)Visual inspections, test notification appliances,
perform daily and weekly routine maintenance and record inspection results
MFSPC - (ANSWER)Master fire suppression piping contractor
MP - (ANSWER)Master plumber
MFSPC w/s12/15 can - (ANSWER)Inspect, test, maintain and repair/replace system components
MP with S12/15 can only work on - (ANSWER)Residential with 30 sprinkler heads or less and
no booster pump
Page 1 of 5
, Deluge system - (ANSWER)All sprinkler heads are open, pipes dry
ELO extra large orifice sprinkler - (ANSWER)Orifice size greater than 1"
Extended coverage sprinklers head - (ANSWER)Covers max 400sqft in light hazard and 144sqft
for high hazard areas
Large orifice sprinkler - (ANSWER)Orifice greater than 3/4" but smaller than 1"
RTI - (ANSWER)Response time index
SIN - (ANSWER)Sprinkler identification numbers required on sprinkler heads manufactured
after 1/1/2000
Minimum maintained building temperature - (ANSWER)40deg F
System where water is stored in pipes. - (ANSWER)Automatic wet system
System where air is stored in pipes - (ANSWER)Automatic Dry system
Psi in dry system piping - (ANSWER)15-20psi
Has no water in pipes until fire/smoke is detected - (ANSWER)Pre action system
Who needs to draw sketch of compactor garbage Shute sprinkler system - (ANSWER)CoF
holder
_____________ sprinkler heads have been recalled - (ANSWER)Cycling sprinkler heads