GUIDE TESTED CONTENT
◉ The catheter is first inserted into ______ for a pulmonary
angiogram? Answer: Vein
◉ Which of the following is not a type of pacemaker?
a. Triple atrium pacemaker
b. Single pacemaker
c. Dual pacemaker
d. Biventricular pacemaker. Answer: Triple atrium pacemaker
◉ Which of the following is the total volume for carotid angiography
in the Arch?
a. 30-50ml
b. 11-12ml
c. 4-6ml
d. 8-9ml Answer: 30-50ml
◉ An EKG is performed for which of the following reasons?
a. Determine unexplained chest pain
b. Determine the reason for headache
,c. Determine changes in mood
d. Determine stomach pain Answer: a. Determine unexplained chest
pain
◉ Odansetron (Zofran) is a medication used to treat or prevent
nausea and vomiting. What is the proper IV dose of this medicine for
the average adult patient? Answer: 4mg, repeat x 1 if necessary
◉ Regarding the coagulation profile, what is the normal time range
for bleeding time? Answer: 2-9 minutes
◉ Normal time range for Prothrombin time in adult Answer: 10 - 13
seconds
◉ Normal time range for Partial thromboplastin time in adult
Answer: 22 - 35 seconds.
◉ Normal time range for Thrombin time in adult Answer: 18 - 25
seconds
◉ Which of the following is done by sending an electric shock to the
heart using electrodes?
a. Angioplasty
b. Cardioversion
,c. Shunt detection
d. Ventricular volume measurement Answer: Cardioversion
◉ Which of the following is the typical field size (cm) for the
Anteroposterior calf vessels view of a lower limb angiogram?
a. 50
b. 30
c. 20
d. 40 Answer: d. 40.
For the Anteroposterior calf vessels view of a lower limb angiogram,
the typical parameters are:
Contrast volume (mL): 10 - 20
Injection rate (mL/s): 5
Frame rate (frames per second): 1
Field size (cm): 40
Inject delay (s): 0
X-ray delay (s): Increase as necessary
◉ Which size guide wire is typically used with balloons for
peripheral interventions?
a. 0.035 inch
b. 0.018 inch
, c. 0.021 inch
d. 0.001 inch Answer: a. . 035 inch
The small guide wires are typically. 018 inch. They may be as small
as .014 inch. The larger guide wires used with balloons are .035
inch.
◉ Why would a right ventriculogram be performed? Answer: To
determine if there is and why there is an abnormal blood flow on the
right side of the heart
A right heart ventriculography evaluates images of both the right
atrium and right ventricle. It is performed to determine if there is
and why there is an abnormal blood flow on the right side of the
heart. Abnormal results include: weakened pumping functions,
abnormal pressures, abnormalities in the right side of the heart
valves, abnormalities in the right atrium, and abnormal connections
between both sides of the heart. Risks include: cardiac arrhythmias,
cardiac tamponade, embolism, heart attack, infection, hemorrhage,
kidney damage, stroke, and low blood pressure. This procedure can
also be done with coronary angiograms.
◉ To prepare for a ventriculography, patients should be instructed
to do what? Answer: Not to eat or drink 6 to 8 hours before the
procedure