• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 2 fuera de 8 páginas
Examen

ASE Test Prep - A7 Heating and Air Conditioning - Practice Test #1 comprehensive Questions and Answers with Verified Solutions

Document preview thumbnail
Vista previa 2 fuera de 8 páginas

ASE Test Prep - A7 Heating and Air Conditioning - Practice Test #1 comprehensive Questions and Answers with Verified Solutions

Vista previa del contenido

ASE Test Prep - A7 Heating and Air
Conditioning - Practice Test #1
comprehensive Questions and Answers
with Verified Solutions
Question 1:
Technician A says AC system pressures will vary with changes in outside
temperature. Technician B says vent temperatures will vary depending on
ambient temperature. Who is correct? A. Technician A only B. Technician
B only C. Both Technicians A and B D. Neither Technician A nor B

Answer:
Both Technicians A and B


Question 2:
A refrigerant identifier is connected to an AC system. The reading is 1%
air and 99% R134A refrigerant. Technician A says the system may have
been open in the past for repairs, due to the small amount of air.
Technician B says the system can safely be recovered into a recovery
machine. Who is correct? A. Technician A only B. Technician B only C.
Both Technicians A and B D. Neither Technician A nor B

Answer:
Both Technicians A and B

, Question 3:
Prior to a repair, a technician is recovering refrigerant from an AC system.
Several minutes after recovery has completed, the low side remains in
vacuum. Which of the following could this indicate? A. The system has
been completely recovered B. There is too much oil in the system C.
There is still some refrigerant left in the system D. There is excessive
moisture in the system

Answer:
The system has been completely recovered


Question 4:
Technician A says some HVAC actuator motors may require calibration
with a scan tool after replacement. Technician B says some actuators are
automatically calibrated in the self-diagnostic mode. Who is correct? A.
Technician A only B. Technician B only

Answer:
Both Technicians A and B


Question 5:
recovered from the AC system. Technician B says all components of the
AC system should be checked, and verified fully operational before
performing the retrofit. Who is correct? A. Technician A only B.
Technician B only C. Both Technicians A and B D. Neither Technician A
nor B

Answer:
Technician B only Technician A says that prior to performing a R134A
retrofit, R12 does not need to be

Información del documento

Subido en
23 de septiembre de 2026
Número de páginas
8
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$14.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
0
Seguidores
0
Artículos
199
Última venta
-



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes