INDUSTRIAL ELECTRICIAN V5 (NCCER EXAM)
EXAM : INDUSTRIAL ELECTRICIAN V5 (NCCER EXAM)
Study online at https://quizlet.com/_dm47qv
1. The PEAK voltage in a normal 120/208 VAC system 170 V.
is:
2. What is a fish tape used for? Pulling wire or rope through con-
duit
3. As the ambient temperature surrounding a Increases.
self-regulating heating cable gets warmer, the
4. Rubber personnel protective insulating equip- Expiration date.
ment must be marked with the appropriate volt-
age rating and
5. Which plan indicates the location of structures Site
and equipment on a property?
6. THWN conductors have an outer jacket made of: Nylon
7. Which of the following is the classified location Class I Div I
where combustible vapors are always present?
8. When installing more than one ground rod, what 10 ft.
is the MINIMUM spacing between rods
9. The length of bare copper conductor in a ground 10 ft.
ring MUST be buried no less than 2.5' below
grade and
10. What is the purpose of sealing cable ends that are To keep moisture from entering in.
in storage?
11. What is the multiplier from calculating a 45-de- 1.414
gree offset when conduit is being bent?
, INDUSTRIAL ELECTRICIAN V5 (NCCER EXAM)
EXAM : INDUSTRIAL ELECTRICIAN V5 (NCCER EXAM)
Study online at https://quizlet.com/_dm47qv
12. Where raceways connect an enclosure required Not required.
to be dust/ ignition proof to an enclosure in an
UNCLASSIFIED location
13. Which typed of rigid metal conduit would be most Stainless steel
appropriate for a corrosive environment?
14. A material with poor electrical conducting prop- Insulator
erties is a good
15. Insulation on the barrel of crimp connectors for Red
wires sized 22-16 AWG are typically colored.
16. A protective device for limiting voltage spikes by Surge protector.
discharging or bypassing surge current is called
a
17. A Type LB conduit body has the cover on The back.
18. All of the following are common service voltage in 372/575 three-phase, four-wire.
the United States EXCEPT
19. Why should the test leads of a "megger" NEVER It could result in an electrical
be touched by anyone when in use? shock.
20. What is the purpose of lockout/ tagout? Prevent operation.
21. With a row of 3-4" conduits and second row of 32"
3-2" and 2-1" conduits for a angle pull box what
is the MINIMUM distance between the pull box?
22. How should heat-shrink insulators be installed? The insulator should be slipped
over the connector and heat
EXAM : INDUSTRIAL ELECTRICIAN V5 (NCCER EXAM)
Study online at https://quizlet.com/_dm47qv
1. The PEAK voltage in a normal 120/208 VAC system 170 V.
is:
2. What is a fish tape used for? Pulling wire or rope through con-
duit
3. As the ambient temperature surrounding a Increases.
self-regulating heating cable gets warmer, the
4. Rubber personnel protective insulating equip- Expiration date.
ment must be marked with the appropriate volt-
age rating and
5. Which plan indicates the location of structures Site
and equipment on a property?
6. THWN conductors have an outer jacket made of: Nylon
7. Which of the following is the classified location Class I Div I
where combustible vapors are always present?
8. When installing more than one ground rod, what 10 ft.
is the MINIMUM spacing between rods
9. The length of bare copper conductor in a ground 10 ft.
ring MUST be buried no less than 2.5' below
grade and
10. What is the purpose of sealing cable ends that are To keep moisture from entering in.
in storage?
11. What is the multiplier from calculating a 45-de- 1.414
gree offset when conduit is being bent?
, INDUSTRIAL ELECTRICIAN V5 (NCCER EXAM)
EXAM : INDUSTRIAL ELECTRICIAN V5 (NCCER EXAM)
Study online at https://quizlet.com/_dm47qv
12. Where raceways connect an enclosure required Not required.
to be dust/ ignition proof to an enclosure in an
UNCLASSIFIED location
13. Which typed of rigid metal conduit would be most Stainless steel
appropriate for a corrosive environment?
14. A material with poor electrical conducting prop- Insulator
erties is a good
15. Insulation on the barrel of crimp connectors for Red
wires sized 22-16 AWG are typically colored.
16. A protective device for limiting voltage spikes by Surge protector.
discharging or bypassing surge current is called
a
17. A Type LB conduit body has the cover on The back.
18. All of the following are common service voltage in 372/575 three-phase, four-wire.
the United States EXCEPT
19. Why should the test leads of a "megger" NEVER It could result in an electrical
be touched by anyone when in use? shock.
20. What is the purpose of lockout/ tagout? Prevent operation.
21. With a row of 3-4" conduits and second row of 32"
3-2" and 2-1" conduits for a angle pull box what
is the MINIMUM distance between the pull box?
22. How should heat-shrink insulators be installed? The insulator should be slipped
over the connector and heat