AMI 302 Final Review
Study online at https://quizlet.com/_jikwen

1. In a 1T field, H protons 1 me- 43.2; 42.6 x field strength. 42.6 x 1.014 = 43.2MHz
ter from isocenter will pre-
cess at ____ if a 14mT/m gra-
dient is applied.

2. The slew rate is: gradient rise time and amplitude combined; mt/second

3. The duty cycle is: Percentage of time a gradient is applied.

4. The gradient amplitude is: Slope and strength of a gradient

5. The z coils are positioned on False; The z coils are positioned at the head and foot. Y are
the front and back of the gra- positioned on the front and back producing coronal images.
dient cylinder and produce
axial images. (true or false)

6. The Y gradient could logically true; Y or Z could be used.
be used for frequency encod-
ing in a sagittal image. ( true
or false)

7. When a gradient is ap- increase in isocenter in one direction and decrease in the other.
plied, precessional frequen-
cies will....

8. The process of shimming is make the field more homogenous
to:

9. The shields do: Contain the main field to a smaller area

10. The gradient: Gradually adjusts the precessional frequencies of nuclei

11. Passive shields are: Steel lined walls


1/7

, AMI 302 Final Review
Study online at https://quizlet.com/_jikwen

12. RF cage is made with Copper

13. Which of the following de- Heating at skin surface contact points
scribes the antenna effect?

14. RF or zipper artifacts on im- Stray RF or artifacts from outside the MR room entering.
ages are caused by

15. List some differences in a re- a resistive magnet needs a power source and can be turned off
sistive magnet and a super- easily while a superconducting magnet cannot be shut off easily.
conducting magnet: The superconducting magnet is more powerful.

16. Increased gradient ampli- thinner slices
tudes allow for:

17. Decreased gradient ampli- Larger FOV's (field of views)
tudes allow for

18. The MR technologist will typi- primary recieve coil
cally position and place which
system component prior to
each exam?

19. What is true regarding vol- They wrap completely around the part, provide uniform signal,
ume coils? and cause an increase in noise.

20. Which logical gradient could y and z
be used to phase encode this
image?




2/7

Información del documento

Subido en
21 de agosto de 2026
Número de páginas
7
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$11.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
BrainBoostQA
3.0
(1)
Vendido
10
Seguidores
0
Artículos
1735
Última venta
2 semanas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes