What is the minimum size of a water meter and service piping in inches for a water supply system of 34 fixture units with a maximum developed length of 200 feet. The water pressure of the system is 35 psi. - CORRECT ANSWER-1 Table AP201.1

Document preview thumbnail
Vista previa 4 fuera de 90 páginas

What is the minimum size of a water meter and service piping in inches for a water supply system of 34 fixture units with a maximum developed length of 200 feet. The water pressure of the system is 35 psi. - CORRECT ANSWER-1 Table AP201.1

Vista previa del contenido

IRC Plumbing Practice Test Questions And Answers
2025/2026



What is the minimum size of a water meter and service piping in inches
for a water supply system of 34 fixture units with a maximum
developed length of 200 feet. The water pressure of the system is 35
psi. - CORRECT ANSWER-1


Table AP201.1


What is the minimum sized trap that can be used for the drainage
system of a bathtub (with or without shower head and/or whirlpool
attachments)? - CORRECT ANSWER-1.5


Table P3201.7


A water heater pan drain must extend full-size and terminate over a
suitably located indirect waste receptor or must extend to the exterior
of the building and terminate not less than _____ inches and not more
than _____ inches above the adjacent ground surface. - CORRECT
ANSWER-6, 24

,P2801.6.2


A laundry tray waste line is permitted to connect into a standpipe for
automatic clothes washer drain. The standpipe must extend not less
than _____ above the trap weir and must extend above the flood level
rim of the laundry tray. - CORRECT ANSWER-30 inches (762 mm)


P2706.1.2.1


Clothes closets, linen closets and pantries not exceeding _____ in area,
with the smallest dimension not greater than 3 feet (915 mm) and
having wall and ceiling surfaces of gypsum board will not require fire
sprinklers. - CORRECT ANSWER-24 square feet (2.2 m2)


P2904.1.1


If a water closet can be removed to provide cleanout access, does that
fulfill the cleanout requirement of the code? - CORRECT ANSWER-No


P3005.2.3

,Appliances and equipment used for heating water or storing hot water
have to be protected by _____. - CORRECT ANSWER-pressure-relief
valve and temperature-relief valve or a combination pressure and
temperature-relief valve.


P2804.1


Where the fixture drains connect at different levels, the common vent
must connect as a _____ extension of the _____ drain. - CORRECT
ANSWER-vertical, vertical


P3107.3


The minimum air gap distance in inches for lavatories and other fixtures
with effective opening not greater than 1/2 inch in diameter that are
close to a wall is: - CORRECT ANSWER-1.5


Table P2902.3.1


In areas prone to flooding as established by the code, water supply
systems must be designed and constructed to prevent _____ of
floodwaters. - CORRECT ANSWER-infiltration

, P2602.2


When either a public water-supply or sewer system, or both, are not
available, _____, an individual water-supply or individual sewage-
disposal system, or both, must be provided. - CORRECT ANSWER-or
connection thereto is not feasible


P2602.1


_____ installed in a bathroom are not required to be installed within an
enclosure. - CORRECT ANSWER-direct-vent water heaters


M2005.2


For water supply systems used predominantly for flush tanks having a
water supply fixture unit load of 12, what is the comparable demand in
gallons per minute. - CORRECT ANSWER-16.0


Table P2903.6(1)


Test equipment, materials and labor must be furnished by the ______ -
CORRECT ANSWER-permittee

Información del documento

Subido en
19 de agosto de 2026
Número de páginas
90
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$13.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
0
Seguidores
0
Artículos
217
Última venta
-



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes