Cross connection control exam
2026/2027 with correct answers

Water pureyor - ANSWER-Who is responsible for the installation and use of lines on a premise
and for the avoidance of cross connections?



Backpressure - ANSWER-What condition may cause a reversal of flow in water lines?



In an accessible location above ground - ANSWER-Where is the best place to install a pressure
reducer backflow prevention device?



-It is easily altered

-water pressure is lost. - ANSWER-What are the limitations of air-gap separation?



-Double check valve assembly

-pressure vacuum breaker

-reduced pressure printable device - ANSWER-In the testing of which of the following is a
differential pressure gauge used?



No valves allowed downstream - ANSWER-Which of the following is a/are installation
requirement(s) for an atmospheric vacuum breaker?



Double check valve assembly - ANSWER-What do you call a device that consist of two internally
loaded check valves?

, 12 months - ANSWER-Under the specifications of the foundation of cross connection control
and hydraulic research, what is the minimum period of trouble-free field service required for a
device to gain approval?



1 inch - ANSWER-An air-gap my never be less than how many inch(es)?



Twelve inches above the highest outlet - ANSWER-What is the required minimum height of a
water supply line above the overflow rim of a receptacle or waste line for a proper air gap?



At least three PSI - ANSWER-What should be the difference between the opening point of the
relief valve and the differential across the first check valve in order to minimize excessive
discharges due to pressure fluctuations in the supply line?



At least 12 inches above the floor - ANSWER-Where must the relief valve discharge port of a
reduce pressure principal backflow preventer be installed?



Pressure vacuum breaker - ANSWER-Which device has a spring loaded air opening downstream
from a single check valve?



Two lines the diameter of the supply line - ANSWER-What is the minimum airgap separation?



-Test #1 check valve for leakage

-Test #2 check valve for leakage

-Test the relief valve to see if it will open at a differential of two PSI - ANSWER-What conditions
are checked when testing a reduced pressure backflow preventer.



Approved air gap separator - ANSWER-What protection is equal to or better than a reduced
pressure backflow prevention device?

Información del documento

Subido en
7 de agosto de 2026
Número de páginas
5
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$18.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
0
Seguidores
0
Artículos
48
Última venta
-


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes