Question 1: According to New Mexico Construction Industries Division (CID)
regulations, what is the primary scope of work authorized under a GB-2
Residential Building Contractor license?

A. Commercial high-rise construction exceeding three stories
B. Residential construction, remodeling, and repair of one- and two-family dwellings
and associated accessory structures
C. Public infrastructure and highway construction
D. Industrial plant construction only

CORRECT ANSWER: B. Residential construction, remodeling, and repair of one-
and two-family dwellings and associated accessory structures

Rationale: The GB-2 license specifically authorizes contractors to perform residential
building work on one- and two-family dwellings, townhouses, and related accessory
buildings as defined by New Mexico CID rules.

Question 2: Under New Mexico contractor licensing law, how long is a GB-2
Residential Building Contractor license typically valid before renewal is
required?

A. One year
B. Two years
C. Three years
D. Five years

CORRECT ANSWER: A. One year

Rationale: New Mexico CID requires most contractor licenses, including the GB-2, to
be renewed annually, subject to continuing education and fee requirements.

Question 3: According to the International Residential Code (IRC) as adopted
in New Mexico, what is the minimum required compressive strength for
concrete used in residential foundation walls?

A. 1,500 psi
B. 2,000 psi
C. 2,500 psi
D. 3,000 psi


Page 1 of 59

,CORRECT ANSWER: C. 2,500 psi

Rationale: The IRC requires a minimum specified compressive strength of 2,500 psi
for concrete in foundation walls and other structural residential applications unless
otherwise specified by engineering.
Question 4: In New Mexico, which agency is primarily responsible for the
licensing and regulation of residential building contractors?

A. New Mexico Department of Transportation
B. Construction Industries Division (CID) of the Regulation and Licensing
Department
C. New Mexico Environment Department
D. State Fire Marshal’s Office

CORRECT ANSWER: B. Construction Industries Division (CID) of the Regulation
and Licensing Department

Rationale: The Construction Industries Division (CID) is the state agency charged
with licensing, regulating, and enforcing standards for contractors, including GB-2
Residential Building Contractors.

Question 5: According to New Mexico law, what is the minimum amount of
liability insurance typically required for a licensed GB-2 Residential Building
Contractor?

A. $50,000
B. $100,000
C. $300,000
D. $1,000,000

CORRECT ANSWER: C. $300,000

Rationale: New Mexico CID regulations require licensed contractors to maintain
general liability insurance with minimum limits commonly set at $300,000 per
occurrence for residential building contractors.

Question 6: Under the IRC as adopted in New Mexico, what is the minimum
required height for a guardrail on a residential deck more than 30 inches
above grade?

A. 30 inches
B. 34 inches
C. 36 inches
D. 42 inches

CORRECT ANSWER: C. 36 inches

Rationale: The IRC requires guards to be a minimum of 36 inches in height for
residential decks and balconies located more than 30 inches above the adjacent


Page 2 of 59

,grade.

Question 7: According to New Mexico contractor law, a GB-2 licensee who
performs work outside the scope of the residential license may be subject to
which of the following?

A. Automatic upgrade of the license
B. Disciplinary action including fines, suspension, or revocation of the license
C. No penalty if the work is performed correctly
D. A written warning only

CORRECT ANSWER: B. Disciplinary action including fines, suspension, or
revocation of the license

Rationale: Performing work outside the licensed classification violates New Mexico
CID rules and can result in formal disciplinary action against the contractor’s license.

Question 8: In residential framing according to the IRC, what is the maximum
allowable spacing for 2x4 studs in a non-bearing wall supporting only ceiling
and roof loads in a typical New Mexico home?

A. 12 inches on center
B. 16 inches on center
C. 24 inches on center
D. 30 inches on center

CORRECT ANSWER: C. 24 inches on center

Rationale: The IRC permits 2x4 studs spaced at 24 inches on center in non-bearing
walls under specified conditions, provided all other structural requirements are met.

Question 9: According to New Mexico regulations, how many hours of
continuing education are typically required for renewal of a GB-2 Residential
Building Contractor license?

A. 4 hours
B. 8 hours
C. 16 hours
D. 30 hours

CORRECT ANSWER: B. 8 hours

Rationale: New Mexico CID generally requires licensed contractors to complete a
minimum of 8 hours of approved continuing education during each renewal cycle.

Question 10: Under the IRC as adopted in New Mexico, what is the minimum
required width of a hallway in a residential dwelling?

A. 30 inches


Page 3 of 59

, B. 36 inches
C. 42 inches
D. 48 inches
CORRECT ANSWER: B. 36 inches

Rationale: The IRC establishes a minimum hallway width of 36 inches to provide
adequate egress and accessibility within residential dwellings.

Question 11: According to New Mexico law, a written contract is required for
residential construction projects exceeding which approximate dollar amount?

A. $500
B. $1,000
C. $2,000
D. $7,500

CORRECT ANSWER: C. $2,000

Rationale: New Mexico contractor regulations require a written contract for
residential projects above a specified threshold, commonly $2,000, to protect
consumers and define the scope of work.

Question 12: In New Mexico residential construction, what is the minimum
required thickness for a concrete slab-on-grade floor in a typical single-family
dwelling?

A. 2 inches
B. 3.5 inches
C. 4 inches
D. 6 inches

CORRECT ANSWER: B. 3.5 inches

Rationale: The IRC requires a minimum concrete slab thickness of 3.5 inches for
residential slab-on-grade floors, unless otherwise engineered.

Question 13: According to New Mexico CID rules, who is ultimately
responsible for ensuring that a residential construction project complies with
the approved plans and applicable codes?

A. The homeowner only
B. The licensed GB-2 contractor
C. The material supplier
D. The real estate agent

CORRECT ANSWER: B. The licensed GB-2 contractor

Rationale: The licensed contractor is responsible for performing the work in
accordance with the codes, approved plans, and permit requirements.


Page 4 of 59

Información del documento

Subido en
5 de agosto de 2026
Número de páginas
59
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$22.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TutorExpert
3.7
(76)
Vendido
569
Seguidores
314
Artículos
10348
Última venta
11 horas hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes