Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 4 fuera de 144 páginas
Examen

SCAN WITH CONFIDENCE: The CT Tech's Ultimate Registry Success Guide

Document preview thumbnail
Vista previa 4 fuera de 144 páginas

Don't let the CT registry exam blur your vision! This power-packed question bank covers every aspect of computed tomography from Hounsfield units to helical scanning protocols. With 300+ questions on patient positioning, radiation safety, contrast administration, and image reconstruction algorithms, you'll walk into your exam with the clarity of a 512x512 matrix. Perfect for radiologic technologists advancing to CT specialization and students completing their clinical rotations. Master the physics, ace the anatomy, and decode those artifact questions

Vista previa del contenido

1|Page




CT Registry Exam 2026-2027 BANK QUESTIONS WITH
DETAILED VERIFIED ANSWERS EXAM QUESTIONS
WILL COME FROM HERE (100% Latest Already Graded
A+




1. In computed tomography, the primary purpose of the bowtie filter is
to:
A. Increase spatial resolution
B. Reduce patient dose by equalizing x-ray intensity across the detector
array
C. Enhance contrast resolution
D. Decrease image noise


Answer: B
The bowtie filter is shaped to compensate for the varying thickness of
the patient. It attenuates the x-ray beam more at the edges than at the
center, equalizing the intensity reaching the detectors and significantly
reducing overall patient dose.

,2|Page


2. The mathematical technique used to reconstruct CT images from
projection data is known as:
A. Fourier transform
B. Filtered back projection
C. Iterative reconstruction
D. Maximum likelihood expectation maximization


Answer: B
Filtered back projection remains the standard reconstruction algorithm
in most clinical CT systems. It applies a mathematical filter to the
projection data before back-projecting it to generate a cross-sectional
image.


3. The CT number of water on the Hounsfield scale is:
A. -1000
B. 0
C. +1000
D. +500


Answer: B
The Hounsfield scale is defined such that water has an attenuation
value of 0 Hounsfield units (HU). Air is -1000 HU, and dense bone is
approximately +1000 HU, though this can vary.

,3|Page


4. Partial volume artifact occurs when:
A. The patient moves during the scan
B. A single voxel contains multiple tissue types
C. The x-ray tube is overheated
D. The detector array is misaligned


Answer: B
Partial volume averaging occurs when a voxel includes two or more
different tissues with significantly different attenuation coefficients. The
resulting CT number is the weighted average of these tissues, which
may not accurately represent either one.


5. In helical CT, the term pitch is defined as:
A. Table travel per rotation divided by beam collimation
B. Beam collimation divided by table travel per rotation
C. Rotation time divided by table speed
D. Table speed multiplied by beam collimation


Answer: A
Pitch is the ratio of table movement per gantry rotation to the x-ray
beam collimation width. A pitch of 1.0 means the table advances
exactly one beam width per rotation.

, 4|Page


6. The primary advantage of multidetector CT (MDCT) over single-slice
CT is:
A. Lower patient dose
B. Faster scan times and improved longitudinal resolution
C. Higher tube voltage
D. Simpler reconstruction algorithms


Answer: B
MDCT allows for much faster scanning of larger volumes with thinner
slices, improving both temporal and longitudinal resolution. It enables
cardiac, trauma, and whole-body angiography examinations.


7. The relationship between spatial resolution and the reconstruction
matrix is:
A. A 512x512 matrix provides the same resolution as a 1024x1024
matrix
B. A 1024x1024 matrix may provide better spatial resolution
C. A smaller matrix always improves resolution
D. Matrix size has no effect on resolution


Answer: B
A larger reconstruction matrix (e.g., 1024x1024) results in smaller pixel
sizes, potentially improving spatial resolution. However, this requires
more data and increases image noise unless dose is increased.

Información del documento

Subido en
5 de agosto de 2026
Número de páginas
144
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$25.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
2
Seguidores
2
Artículos
1446
Última venta
1 mes hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes