TCEQ Class C Water License Exam / Texas Wastewater Class A Already Passed!! How should shoring be removed from a trench? - ANSWER-up from the bottom up In low pressure sewer systems where each tap must have a grinder pump lift station, station is considered to be - ANSWER-part of the collection system and the responsibility of the utility Effective communication depends on - ANSWER-being a good listener When designing a wastewater collection system, the engineer considers the population for how many years in the future? - ANSWER-50 According to 30 TAC Chapter 317, all pipe and fittings used in wastewater pressure shall have a minimum psi pressure rating of - ANSWER-150 The minimum velocity of flow in a wastewater line should be - ANSWER-2.0 fps At a construction job site, as the roadway speed increases, the spacing between cones and barricades should - ANSWER-increase The major cause of wastewater line stoppages is - ANSWER-roots and grease Carbon monoxide (CO) poisoning symptoms are - ANSWER-tightness in the chest nausea drowsiness and headache (all of the above) The smallest pipe size for air recirculation of a self-priming centrifugal pump is - ANSWER-1 inch Dangerous gases in a confined space may not be detected with the physical senses because - ANSWER-some gases have no odor some gases may deaden the sense of smell some gases may displace the oxygen (all of the above) What are the dangerous gases a collection system worker might come into contact with? - ANSWER-CO2 CO НaS CH4 (all of the above) On a construction job site, equipment booms must maintain at least how many feet of clearance from overhead electric lines? - ANSWER-10 How should trench shoring be installed? - ANSWER-to above the top of the trench When setting work goals for an employee, the goals should be - ANSWER-accompanied by an action plan According to Chapter 317, Design Criteria, a manhole can be installed within 9 feet of an existing waterline if - ANSWER-the manhole is completely watertight and tested for no leakage As the population of a collection system increases, the ratio of peak flow to average daily flow will - ANSWER-decrease Motivating workers to do a better job is best done by - ANSWER-letting workers participate in setting goals One important element of a good communicator is - ANSWER-being a good listener Monitoring and reporting records of a wastewater treatment plant shall be kept at the facility site for a period of - ANSWER-d. three years The TCEQ Design Criteria requires that deflection tests be performed on all new installed flexible or semi-rigid pipe after the final backfill has been in place for 30 days. This deflection test is usually performed using a rigid ball or mandrel that has a diameter equal to -percent of the inside diameter of the pipe. - ANSWER-c. 95

Vista previa del contenido

TCEQ Class C Water License Exam / Texas
Wastewater Class A Already Passed!!

How should shoring be removed from a trench? - ✔✔✔ANSWER-up from the

bottom up


In low pressure sewer systems where each tap must have a grinder pump lift
station, station is considered to be - ✔✔✔ANSWER-part of the collection
system and the responsibility of the utility




Effective communication depends on - ✔✔✔ANSWER-being a good listener


When designing a wastewater collection system, the engineer considers the
population for how many years in the future? - ✔✔✔ANSWER-50


According to 30 TAC Chapter 317, all pipe and fittings used in wastewater
pressure shall have a minimum psi pressure rating of - ✔✔✔ANSWER-150 The
minimum velocity of flow in a wastewater line should be -

✔✔✔ANSWER-2.0 fps

At a construction job site, as the roadway speed increases, the spacing between
cones and barricades should - ✔✔✔ANSWER-increase

,The major cause of wastewater line stoppages is - ✔✔✔ANSWER-roots and
grease




Carbon monoxide (CO) poisoning symptoms are - ✔✔✔ANSWER-tightness
in the chest nausea drowsiness and headache (all of the above)


The smallest pipe size for air recirculation of a self-priming centrifugal pump is -

✔✔✔ANSWER-1 inch

Dangerous gases in a confined space may not be detected with the physical senses
because - ✔✔✔ANSWER-some gases have no odor some gases may deaden
the sense of smell some gases may displace the oxygen (all of the above)


What are the dangerous gases a collection system worker might come into contact
with? - ✔✔✔ANSWER-CO2 CO НaS CH4 (all of the above)

On a construction job site, equipment booms must maintain at least how many feet
of clearance from overhead electric lines? - ✔✔✔ANSWER-10



How should trench shoring be installed? - ✔✔✔ANSWER-to above the top of
the trench


When setting work goals for an employee, the goals should be -

, ✔✔✔ANSWER-accompanied by an action plan

According to Chapter 317, Design Criteria, a manhole can be installed within 9 feet
of an existing waterline if - ✔✔✔ANSWER-the manhole is completely
watertight and tested for no leakage


As the population of a collection system increases, the ratio of peak flow to
average daily flow will - ✔✔✔ANSWER-decrease



Motivating workers to do a better job is best done by - ✔✔✔ANSWER-letting
workers participate in setting goals




One important element of a good communicator is - ✔✔✔ANSWER-being a
good listener


Monitoring and reporting records of a wastewater treatment plant shall be kept at
the facility site for a period of - ✔✔✔ANSWER-d. three years

The TCEQ Design Criteria requires that deflection tests be performed on all new
installed flexible or semi-rigid pipe after the final backfill has been in place for 30
days. This deflection test is usually performed using a rigid ball or mandrel that has
a diameter equal to -percent of the inside diameter of the pipe. -

✔✔✔ANSWER-c. 95

Información del documento

Subido en
3 de agosto de 2026
Número de páginas
30
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$13.79

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TheExamMaestro
3.6
(18)
Vendido
149
Seguidores
5
Artículos
3668
Última venta
13 horas hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes