When topping off an operating system containing a blended refrigerant - Correct


answer introduce the refrigerant a a liquid into the low side using a throttling valve.




A partially clogged capillary tube metering device can cause - Correct answer a


starved evaporator




The R134-A high pressure gauge reads 146 psig and the liquid line temp. At the


condensing unit is 95 degrees faranheit, what is the operating subcooling - Correct


answer 15 degrees faranheit




An overcharge of refrigerant will cause - Correct answer increased head pressure




A drain trap should be installed on a split system when the - Correct answer Air


handler drain is on the negative side

,A customer complains that their AC system is running constantly, but not cooling


enough. The suction line is very colde and the compressor is sweating. Mostlikely


cause is - Correct answer a restriction of the return air or dirty evaporator




What is the generally accepted range for evaporator air flow in cfms per ton of


residential air conditioning? - Correct answer 350 to 450




Split system with Compressor change out, unit is not cooling. Evaporator seems


starved, liquid line is sweating leaving the drier, mostlikely - Correct answer Debris


from the burned out compressor has clogged the filter drier




The temperature rise method for determining air flow is - Correct answer CFM=BTU /


(1.08 x Delta T)




What is the recomended residential indoor relative humidity for summer? - Correct


answer 50%

, An inefficient compressor is usually indicated by ___ headpressure and ___ suction


pressure - Correct answer Lower than normal/ higher than normal




Which is NOT a symptom of a hermetic system that is low on refrigerant - Correct


answer High head pressure




Frost on the suction line indicates - Correct answer That the temp. Is below the dew


point and below 32 degrees F.




An increase in head pressure causes __ refrigerant to flow through a capillary tube -


Correct answer More




With an automatic expansion valve, an increase in evaporator load will cause the -

Correct answer Automatic expansion valve to open




When a TEV or a capillary tube is used as a metering device a low refrigerant charge


will cause - Correct answer low head pressure

Información del documento

Subido en
29 de julio de 2026
Número de páginas
18
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$14.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
9
Seguidores
0
Artículos
810
Última venta
2 meses hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes