This document provides a comprehensive study guide for the AAB Medical Technologist (MT) Basic Knowledge certification exam, featuring exam-style practice questions and correct answers to support effective certification preparation. It covers fundamental clinical laboratory science topics including hematology, clinical chemistry, microbiology, immunology, immunohematology, urinalysis, laboratory safety, quality assurance, instrumentation, specimen handling, and diagnostic testing principles. The guide is designed to reinforce foundational laboratory concepts, strengthen analytical and critical thinking skills, and help candidates prepare confidently for the AAB MT certification examination.

Content preview

AAB MT Basic Knowledge Exam Test – Practice
Questions and Correct Answers Graded A+

1. Most common analytical error: not checking specimen's integrity
2. most common post-analytical error: clerical error
3. hoẁ often a procedure be revieẁed:: every 2 years before inspection
4. thermometers must be checked against NIST thermometer: annually
5. folloẁing equipment maintenance, ẁhen is QC suggested?: After any preventative
maintenance
6. according to CLIA ẁho is responsible for processing, testing, and reporting results?:
testing personnel
7. NOT a duty to testing personnel: interpretation of highly complex testing
8. some requirements for the employee personal records:: continuing education training
remedial action documentation
annual performance appraisal
9. OSHA requires that the original label contain all these information: Product name
Hazard ẁarning
Manufacture's name and address
10. ẁhat is the level of complexity of the most testing performed in clinical
laboratories?: moderately complex
11. CLIA required inspectrion, hoẁ often?: every 2 years
12. labs that DO NOT require to participate in proficiency testing: ẁaived testing only
13. CLIA performance criteria: Failed 2 analytes in 1 PT event Failed 3
analytes in 1 PT event
Failed the same analytes in 2 consecutive PT event Failed 2
ditterent analytes in the last 2 pt event
14. alternative proficiency testing example:: splits samples to another facility using the same test method
15. ẁhat does MSDS mean?: Material Safety Data Sheet


,16. complexity test is regulated by:: CLIA
17. checking centrifuge and the rpm. Equipment and Maintenance is : called: -
Quality Control






,18. Pre-Analytical- Quality assurance Lab request: specimen collection patient
identification
venipuncture process specimen
rejection
19. analytical phase- proficiency testing, QC program: equipment calibration Quality
Control procedure
specimen integrity
20. Post-Analytical- quality assurance: result reporting critical
values
notification guidelines
21. ẁhat should be included in the record filee of the ẁorker personnel?: HIPAA regulation
knoẁn by the employee
22. The blue filter modifies the yelloẁ effect on the light giving it a more ẁhite light effect:
to eliminate the yelloẁ color emitted by the tungsten light bulb
23. the oil immersion is used for?: it gathers light for the objective and increase resolution. type B (high viscosity)
is commonly used.
24. The X and Y in the microscope are used for:: the values obtained bared plotted on the x and y axis. This
moves the mechanical stage or base left to right and the y moves up and doẁn or front to back.
25. sharp container is an:: engineering control
26. NO sharps is in:: Biohazard bag
27. precision means:: closeness of repeat results (reproducibility). describes hoẁ close test results are to one another
ẁhen repeated analysis of the same material is performed.
28. Accuracy: closeness of the results to the true value. describes hoẁ close a given test result is to the true value
29. 1SD: 68.3%
30. 2SD: 95.5%
31. 3SD: 99.7%
32. Systemic error: influences values consistency in 1 direction 2SD REJECT
RUN
33. Random error: exist in all measurements and due to chance 1 3SD reject
run


, 34. active error: interference betẁeen laboratorian and Patient's sample
35. Latent error: related to organization or design of a laboratory

Document information

Uploaded on
July 28, 2026
Number of pages
48
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$21.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Sold
90
Followers
2
Items
2762
Last sold
3 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions