Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 3 fuera de 21 páginas
Examen

AWWA Cross-Connection Control Specialist – Exam Questions and Correct Answers

Document preview thumbnail
Vista previa 3 fuera de 21 páginas

This document contains a comprehensive collection of AWWA Cross-Connection Control Specialist exam questions with correct answers for exam preparation. It covers key topics including backflow prevention assemblies, cross-connection control, hazard assessments, field testing procedures, differential pressure gauges, air gaps, vacuum breakers, double check valve assemblies, reduced pressure principle assemblies, and AWWA standards. The material is presented in a question-and-answer format, making it ideal for self-study, revision, and certification exam preparation. It serves as a complete review resource for the AWWA Cross-Connection Control Specialist exam.

Vista previa del contenido

AWWA – Cross-Connection Control Specialist
Exam Questions And Correct Answers



The Check Valves of a Double Check Valve Assembly must be:

Internally Loaded




Which of the following backflow preventers offers effective protection under
backsiphonage conditions only and can also be subjected to constant full line
pressure?

Spill Resistant Type Pressure Vacuum Breaker




To appropriately resolve a cross connection contamination incident, a qualified
tester or specialist should:

Identify and isolate the source of contamination, Identify and isolate the affective
area. Notify the customer, as well as, the health department




Which of the choices is best described as "a flow of water or other liquids back
into the potable water supply due to a negative or reduced pressure in the supply
piping?"

Backsiphonage

,A residential "partial flow through" type fire sprinkler/ standpipe system is
designed to circulate water in what portion(s) of the water system?

Sprinkler system main




The factory loaded spring tensions of the first and second check valves found in a
Reduced Pressure Principle Backflow Assembly are always

Pre loaded different from one another




An Approved Air Gap must be:

Twice the pipe diameter with a minimum of 1 inch separation




Upon completing test number one of a Double Check Valve Assembly, when
using a differential pressure gauge, in what position are the shut off valves for
the next test?

Shutoff valve #1 is open and shutoff valve #2 is closed




According to the AWWA Canadian CCC manual, the minimum vertical distance
from the bottom of a RP's relief valve to the finished floor level should be?

300 mm (12")

, The Dual Check Valve can be used to isolate which one of the following
applications?

Residential potable water systems with a minor degree of hazard




During the field test of a Reduced Pressure Principle Backflow Assembly, it may
be possible to compensate for a leaking number two shutoff valve by attaching a
temporary bypass hose from:

Test cock number one to test cock number four




Backflow prevention assemblies shall be field tested to a minimum of:

Annually




To what maximum centerline height (from the finished floor) must testable
backflow preventers be installed before a fixed platform is to be provided below
the assembly?

1500 mm (5')




Which backflow preventer contains a float check, a check seat and an air inlet
poppet?

Atmospheric Vacuum Breaker

Información del documento

Subido en
27 de julio de 2026
Número de páginas
21
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$11.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Hosmerit
4.7
(255)
Vendido
391
Seguidores
45
Artículos
4476
Última venta
6 días hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes