Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 3 fuera de 16 páginas
Examen

CALIFORNIA ICC SERVICE TECH EXAM |100 COMPLETE QUESTIONS WITH 100% RATED EXPERT SOLUTIONS |2026 LATEST UPDATED

Document preview thumbnail
Vista previa 3 fuera de 16 páginas

CALIFORNIA ICC SERVICE TECH EXAM |100 COMPLETE QUESTIONS WITH 100% RATED EXPERT SOLUTIONS |2026 LATEST UPDATED

Vista previa del contenido

CALIFORNIA ICC SERVICE TECH EXAM |100 COMPLETE QUESTIONS WITH

100% RATED EXPERT SOLUTIONS |2026 LATEST UPDATED

(T/F) Gasoline vapors are lighter than air - (answer)False: Gas vapors are 3-4 times HEAVIER

than air




Overfill Protection notifies the operator when tank is at what level capacity? - (answer)If

equipped it will notify audibly and visually when the tank reaches 90% Capacity.




Cathodic protection systems must be inspected by a certified cathodic protection tester

within______ months of installation - (answer)6 months




Annual Monitor Certification records must be maintained on site for a period of________ years -

(answer)3 years




The minimum monetary punishment for any person who falsifies monitor records is? -

(answer)$5,000




The quickest route for exposure to toxic substance is? - (answer)Inhalation

,For temporary tank closure you still need to monitor the tank but you don't need an engineering

report. Is this a true statement? - (answer)Yes




Asphyxiation is most likely to occur in low lying areas where heavier-than-air-air-vapors

accumulate. Asphyxiation can be caused by: - (answer)An Oxygen depleted environment




Where are ATG probes installed? - (answer)Through an opening in the top of the tank.




What is the minimum fine for disabling a monitoring system? - (answer)$5,000




(T/F) when performing secondary containment testing the spill buckets get tested as well. -

(answer)False: Spill buckets get tested during the annual monitor certification.




Who must the annual monitor certification test results be sent to and when must they be notified

prior to testing and after testing? - (answer)Local agency must be notified prior 48 hours prior

and results must be submitted within 30 days of testing




(T/F) Stage II vapor recovery is a system for exchanging gasoline vapors in a vehicle fuel tank

and product in a storage tank so that vapor omissions to the environment during refueling are

, greatly reduced. - (answer)True: because Stage I vapor recovery is from fuel delivery truck to

storage tank




__________must report an un-authorized release within _________ hours to the local agency -

(answer)The owner or operator

24 hours




If automatic line leak detectors fail testing, what must happen? - (answer)They must be replaced

and be able to detect a release of 3 gallons per hour at 10 pounds per square inch.




(T/F): The area inside the tank covered by fuel is considered the "Ullage" - (answer)False: The

area inside the tank not covered by fuel is considered the "Ullage"




If equipped with an ATG it shall be programmed to test the tank________ - (answer)At least

monthly




(T/F) Spill buckets must provide drainage for spilled product into secondary containment sump?

- (answer)False: spilled product is released back into the tank by the drain valve, not into the

secondary containment (Fill Sump)

Información del documento

Subido en
24 de julio de 2026
Número de páginas
16
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$22.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Henlens
5.0
(501)
Vendido
2191
Seguidores
1
Artículos
506
Última venta
2 días hace

Reseñas de compradores verificados




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes