The sensor of the temperature measuring device shall be submerged a
minimum of _____ in. [_____mm] into the freshly mixed concrete. -
ANSWER ✔✔3 in. [75 mm]
The temperature measuring device shall have a capacity of measuring
temperature of freshly mixed concrete to +- _____ degrees F [+- _____
,C] throughout a range of _____. - ANSWER ✔✔1 degree F [0.5 C],
30 degrees F to 120 F [0 C to 50 C]
The temperature measuring device shall be calibrated _____, or
whenever there is a question of _____. - ANSWER ✔✔Annually,
accuracy
The temperature of concrete may be measured in a wheelbarrow. True
or False? - ANSWER ✔✔True
The temperature of concrete may be measured in a wall form. True of
False - ANSWER ✔✔True
A composite sample of concrete is required even if the only purpose for
obtaining the sample is to determine temperature. True of False? -
ANSWER ✔✔False
What must be done to the sample container prior to sampling the
concrete? - ANSWER ✔✔Dampen (with water)
What must be done to the concrete surrounding the temperature
measuring device after the device is submerged in the fresh concrete. -
ANSWER ✔✔Gently press the concrete around the temperature
measuring device at the surface of the concrete
, How long must the temperature measuring device remain in the freshly
mixed concrete? - ANSWER ✔✔At least 2 minutes but not more than
5 minutes
After the temperature of the concrete is read, what is required? -
ANSWER ✔✔Reporting of temperature
The temperature of concrete is reported to the nearest _____ degrees F
[_____ C] - ANSWER ✔✔1 degree F [0.5 C]
According to ASTM C1064, what is one reason to take the temperature
of concrete? - ANSWER ✔✔Verify conformance to a specified
requirement for temperature of concrete
A maximum temperature of freshly mixed concrete is specified in ASTM
C1064. True of False? - ANSWER ✔✔False
The sample of concrete used for temperature determination must be
rodded 25 times. True or False? - ANSWER ✔✔False
Sampling by this method is required when tests are to be made to
determine _____ with specification requirements. - ANSWER
✔✔Compliance
COPYRIGHT©PROFFKERRYMARTIN 2025/2026. YEAR PUBLISHED 2026. COMPANY REGISTRATION NUMBER: 619652435. TERMS OF USE.