A manual reset local alarm that indicates when the capacity of the instrument
|| || || || || || || || || || || || ||




air central supply system not in use is less than the equivalent capacity of -
|| || || || || || || || || || || || || || ||




✔✔One compressor ||




After a final tie - In on an active vacuum system , each vacuum joints shall be
|| || || || || || || || || || || || || || || || ||




tested with a leak detector or other means that will allow detectant on an active
|| || || || || || || || || || || || || || ||




vacuum system . - ✔✔Ultrasonic || || || ||




After the final tie-in each joint shall be leak tested by the source gas. New work
|| || || || || || || || || || || || || || || ||




and the existing system at the normal operating pressure shall be leak checked
|| || || || || || || || || || || || ||




with a leak detectant that is safe for use with oxygen and does NOT contain
|| || || || || || || || || || || || || || ||




_______________ - ✔✔Ammonia || ||




After the piping system, the blow down test shall be done. Then the installer
|| || || || || || || || || || || || || ||




must perform which of the following test? - ✔✔Initial pressure test
|| || || || || || || || || ||




Alarm panels and shutoff valves labeling shall be ____________ when
|| || || || || || || || || ||




modifications are made, changing the areas serviced - ✔✔Updated || || || || || || || ||




All gas outlets with gauge pressure of 345 kPa (50 psi), including, but not
|| || || || || || || || || || || || || ||




limited to, oxygen, nitrous oxide, medical air, and carbon dioxide, shall deliver
|| || || || || || || || || || || ||

,2


100 SLPM (3.5 SCFM) with a pressure drop of not more than 35 kPa (______)
|| || || || || || || || || || || || || || ||




and static pressure of 345 kPa to 380 kPa (50psi to 55 psi) - ✔✔5 psi
|| || || || || || || || || || || || || || ||




Area alarms shall be tested to verify the warning signals for all vital life support
|| || || || || || || || || || || || || || ||




and critical care areas if the pressure in the piping system increases or decreases
|| || || || || || || || || || || || ||




by _______ - ✔✔20%
|| || || ||




At the sample port a demand of approximated 25% load shall be created to
|| || || || || || || || || || || || || ||




cause the compressors to cycle on and off continuously and the dryers to
|| || || || || || || || || || || || ||




operate for the ______ period. - ✔✔12 hour || || || || || || ||




Before the piping system is put into use, who is responsible for the ascertaining
|| || || || || || || || || || || || || ||




that the gas delivered to the outlet/inlet has the proper labels and connecting
|| || || || || || || || || || || || ||




fittings. - ✔✔Facility authority || || ||




Breached portions of the systems subject to inspection and testing shall be || || || || || || || || || || || ||




confined to only the specific altered zone or area that is downstream for
|| || || || || || || || || || || || ||




pressure gases at the point of intrusion. Where a system shall be declared
|| || || || || || || || || || || || ||




breached? - ✔✔Physical separation of pipeline, system component removal, || || || || || || || || ||




replacement or addition of system components || || || || ||




Category 2 & 3 medical has and vacuum systems are allowed to be ________ on
|| || || || || || || || || || || || || || ||




the amount of compressors and vacuum pumps - ✔✔Simplex
|| || || || || || || ||




Category 2 oxygen piping shall be at least 1 size larger than piping for _______?
|| || || || || || || || || || || || || || ||




- ✔✔Nitrous oxide
|| ||

, 2


Category 3 gas-power device supply systems, vacuum systems and scavenging
|| || || || || || || || || ||




systems. The initial tests shall be performed before the final tests shall be
|| || || || || || || || || || || || ||




conducted by ______. - ✔✔Installer, representative of the system manufacturer,
|| || || || || || || || ||




medical gas system verifier 6030
|| || || || ||




Category 3 piped gas and vacuum systems only ______ shall be permitted. -
|| || || || || || || || || || || || ||




✔✔Minimal or no sedation || || ||




Category 3 vacuum source equipment shall be obtained from, and be installed
|| || || || || || || || || || || ||




under the supervision of the __________? - ✔✔Manufacturer, supplier, who is
|| || || || || || || || || || ||




familiar with its installation, operation and use
|| || || || || ||




Category 2 & 3 medical gas systems are required to have how many alarm
|| || || || || || || || || || || || || ||




panels? - ✔✔1 || ||




Cylinders in service and in storage shall be __________ secured and located to
|| || || || || || || || || || || || ||




prevent falling or being knocked over. - ✔✔Individually
|| || || || || || ||




Dental air sources for a compressor intake located inside the building shall be
|| || || || || || || || || || || || ||




located within a space where no _______ are stored or used. - ✔✔Chemical
|| || || || || || || || || || || || ||




based materials, patient medical treatment, discharge from category 3 vacuum
|| || || || || || || || || ||




system



Dental applications that use flexible connectors shall have a gauge pressure
|| || || || || || || || || || ||




rating not less than _______ - ✔✔1000 psi
|| || || || || || ||

Información del documento

Subido en
20 de julio de 2026
Número de páginas
21
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$21.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Ruiz
3.2
(15)
Vendido
105
Seguidores
2
Artículos
14135
Última venta
2 semanas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes