Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 4 fuera de 53 páginas
Examen

PPD - ARE 5.0 (NCARB) Exam | Verified Exam Questions and Answers | Latest Updated Study Material 2026

Document preview thumbnail
Vista previa 4 fuera de 53 páginas

PPD - ARE 5.0 (NCARB) Exam | Verified Exam Questions and Answers | Latest Updated Study Material 2026

Vista previa del contenido

PPD - ARE 5.0 (NCARB) Exam | Verified Exam Questions and Answers |
Latest Updated Study Material 2026

Question:

1. Annalemma
Answer:

The figure 8 curve that represents the angular offset of the sun from its mean
position at as viewed from the earth

Question:

2. Balance Point
Temperature
Answer:

The outdoor temperature at which a building makes the transition from a heating
to a cooling need

Question:

3. Daylight autono- The percentage of an area that meets a minimum daylight illuminance level or
my
Answer:

specified fraction of the operating hours per year. also referred to as special
daylight autonomy

Question:

4. Daylight factor
Answer:

The ratio expressed as a percentage othe indoor aluminates at a point on a
horizontal surface to the unobstructed Exterior horizontal illuminance

Question:

5. Effective apera-
ture
Answer:

The product of visible transmittance and the window to wall ratio

,Question:

6. Equation of time The factor used to account for the difference between solar time and clock time.
Answer:

Solar time is based on the position of the sun. It's basic unit is the solar day

Question:

7. Glazing factor
Answer:

A LEED based number calculated by taking into account window area, floor area,
a window geometry factor, light transmission, and a window height factor.

Question:

8. Ground light
Answer:

Visible light from the sun and sky, reflected by exterior surfaces below the plane
of the horizon

Question:

9. Light shelf
Answer:

A horizontal element position above eye level and designed to reflect daylight on
the ceiling for improved daylighting effectiveness

Question:

10. Net metering
Answer:

The requirement that a utility pay and charge equal rates regardless of which way
electricity flows as a part of the utility Grid.

Question:

11. Radiation spec-
trum
Answer:

The entire range of electromagnetic radiation extending from 0 hz to 1023 hz. This
includes visible light as well as infrared radiation, radio waves, and gamma rays
among others

,Question:

12. Radiative cooling Passive or active design strategy that uses thermal mass to collect and store heat
Answer:

during the day for release at night. Also known as nocturnal cooling and night
cooled mass

Question:

13. Shading coeffi-
cient
Answer:

The ratio of the solar heat gain thru a glazing product to the solar heat gain
through an untreated 1/8 in clear double strength glass under the same set of
conditions. This is the value for the glass only, does not include the frame

Question:

14. Solar constant
Answer:

The amount of solar energy that falls in our unit time on her unit area that is
93,000,000 miles from the sun and orientated on a plane perpendicular to the
suns rays. The mean value of the solar constant is 433 btu/hr-ft

Question:

15. Solar heat gain
coefficient
Answer:

The ratio of the solar heat gain thru a fenestration to the total solar radiation
incident on the glazing.

Question:

16. Solar time
Answer:

The time as defined by the sun and it's position relative to the earth. Because the
length of the solar day varies most reference the mean solar day as a basis for
timekeeping.

, Question:

17. Solar savings
fraction
Answer:

The fraction of the total energy used by system that is provided by solar technol-
ogy. Represented by the variable F, it is a decimal fraction from 0 to 1

Question:

18. Visible light
transmittance
Answer:

The fraction of visible light that passes through a glazing material

Question:

19. Window to wall
ratio
Answer:

The ratio of the net glazing area in your room or space to the gross exterior wall
area

Question:

20. Work plane
Answer:

This assumed height at which work is performed usually considered to be at a
desk height, 30 inches above the floor

Question:

21. Co product
Answer:

A marketable byproduct from a process. Materials traditionally considered to be
waist but they can be repurposed as raw materials and a different manufacturing
process.

Question:

22. Demand control A system designed to adjust the amount of ventilation air provided to a space
ventilation

Información del documento

Subido en
16 de julio de 2026
Número de páginas
53
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$12.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
5
Seguidores
0
Artículos
4027
Última venta
1 semana hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes