●● 2. Written Plans are required to
Answer: obtain permits, solicit bids, and provide precise guidance for
installers.


●● 3. The plans should
Answer: Describe the property, identify the size and location of the
tanks, indicate the liquids to be stored and provide the location of the
dispensers and piping.


●● 4. Storage systems discussed in this recommended practice are
usually regulated by
Answer: Federal, state or local agencies.


●● 5. All owners should ensure that the equipment to be installed meets
Answer: applicable regulatory requirements before being installed


●● 6. Consult the local authorities who have jurisdiction in the area
before storage-system plans are
Answer: finalized or construction is initiated.

,●● 7. All owners should ensure that the equipment to be installed meets
all applicable regulatory requirements before
Answer: Being installed.


●● 8. To avoid damage tanks must not be
Answer: dropped, dragged, or handled with sharp objects.


●● 9. Tanks must not be dropped, dragged, or handled with sharp
objects to avoid
Answer: Damage to the tank


●● 10. The only time tanks really should be moved is when
Answer: for inspections and testing.


●● 11. If a tanks is damaged at all throughout the moving process it
must be
Answer: Repaired in accordance with the manufacture's instructions.


●● 12. The proper way to move a tank is by lifting it, using the
Answer: Lift lugs that are installed by the manufacturer.


●● 13. Tanks should be carefully lifted and lowered using

,Answer: Cables or chains of adequate length.


●● 14. When two lifting lugs are being used, the angle between the
lifting cable and vertical should be no more than
Answer: 30 degrees.


●● 15. Stockpile piping materials and equipment in a _____________
_________ on the job site
Answer: Secure area


●● 16. Confirm adherence to specifications by reporting to the owner
about any
Answer: detected damage that could result in leakage or premature
corrosion.


●● 17. Pressure test single-walled tanks with _____ to _______ psig air
pressure, soaping all surfaces, seams and fittings while inspecting for
bubbles.
Answer: 3 to 5


●● 18. Air testing with over ___ psig (3 Psig for 12-Ft. Diameter FRP
tanks) is hazardous and may damage the tank
Answer: 5 psig

, ●● 19. Do not air test a tank that has previously contained
Answer: flammable or combustible liquids


●● 20. Place ______ barricades at the ends of tanks being tested.
Answer: Warning


●● 21. Avoid tank ends, man-ways, and fittings while the tank is under
Answer: Pressure


●● 22. Release pressure in the tank before disconnecting any
Answer: gauges or test fittings.


●● 23. Be aware some manufactures do not tighten fittings to allow for
_____________ _____________ during shipping and storage.
Answer: Temperature changes


●● 24. True or False: Air tests are inconclusive without soaping and
careful inspection for bubbles?
Answer: True


●● 25. Tanks gauges must have a scale that will permit detection of
small changes in __________ that might go undetected on gauges with a
___________ _________.

Información del documento

Subido en
15 de julio de 2026
Número de páginas
35
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$13.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TopGradeInsider
4.1
(14)
Vendido
202
Seguidores
1
Artículos
64829
Última venta
9 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes