Question: What are the 3 funtions of an Oil Burner nozzle?
Correct Answer: Atomize, Meter, Patter.
Question: What are the 2 voltage circuits of a primary control?
Correct Answer: Line & Low.
Question: What is the function of a fuse?
Correct Answer: Protect circuit.
Question: What is the High Limit cut out?
Correct Answer: Max safe Temp or Pressure setting.
Question: What is the High Limit cut in?
Correct Answer: Cut out minus Differential.
Question: What is the "Max" Lockout time for a burner with a 3 GPH Flow Rate?
Correct Answer: 45 Seconds.
Question: What is the minimum stack temperature which will allow a stack switch to work?
Correct Answer: 400 degrees F
Question: When do you apply a permit to store oil?
Correct Answer: 10 gallons.
Question: What is the "Main" function of an oil burner Primary Control?
Correct Answer: Prove Flame.
Question: Stack Relay must be reset after lockout? True? or False?
Correct Answer: True.
Question: What is the Required minimum height required for fill and vent pipes?
Correct Answer: 3 Feet.
Question: What is the smallest vent pipe used for residential.
Correct Answer: 1 inch
Question: What size is the oil line for a residential burner?
Correct Answer: The answer is the explanation or keyed response connected to this question in Oil burner
License ( Massachusetts ). It identifies the relevant definition, function, procedure, or principle for this
topic.
Question: Largest oil capacity for residential without a license?
Correct Answer: 10,000 Gallons
Question: At what height ceiling would a second thermal switch be required?

, Correct Answer: 12'
Question: A typical residential oil burner is also s/u to run Kerosene True? Or False?
Correct Answer: False
Question: Permit to install an oil burner is issued by the?
Correct Answer: State Fire Marshall
Question: Draft measurements are taken in what?
Correct Answer: Inches of water column
Question: Pressure Relief for a Hot Water Boiler is?
Correct Answer: 30 Psi
Question: Pressure Relief for a Steam Boiler is?
Correct Answer: 15 Psi
Question: How many cubic feet of Air is required for a 1 gallon nozzle?
Correct Answer: 1,400
Question: If a power vent fails to start or shuts down during operation, will this affect the burner? Yes? Or
No?
Correct Answer: Yes
Question: A Hot Water Boiler needs a low water cut off if over 300,000 B.T.U's?
Correct Answer: False
Question: What is the proper draft setting for an oil burner?
Correct Answer: .02 Inches WC
Question: Taco Zones Valves draw .9 Amps? True? Or False?
Correct Answer: True
Question: An oil burner tank must be how many feet minimum from an oil burner?
Correct Answer: 5 Feet Minimum
Question: What is the gauge thickness for a 220 Gallon tank?
Correct Answer: 12 Gauge
Question: What is a good cad cell reading in the light?
Correct Answer: 300 -1,000
Question: What is a good cad cell reading in the dark?
Correct Answer: 100,000
Question: What device sees flame failure and causes it to lockout?
Correct Answer: Cad Cell
Question: A boiler has been flooded by recent rain. What would be the most common problem for a burner
as a result

Escuela, estudio y materia

Institución
Stuvia
Grado
Stuvia

Información del documento

Subido en
9 de julio de 2026
Número de páginas
7
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$12.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
MGRADES Stanford University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1451
Miembro desde
2 año
Número de seguidores
105
Documentos
97742
Última venta
3 horas hace
MGRADES

Welcome to MGRADES ,Based at Stanford University in California. I guarantee success and you may end up coming back again and again. We do this for you . We offer the best study and exam materials for a wide range of courses and units. Make your study sessions more efficient and effective. Dive in and discover all you need to excel in your academic journey!

3.8

235 reseñas

5
97
4
50
3
53
2
15
1
20

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes