Personnel for Unbonded Post
Tensioning Questions and Answers.
What word best describes an upward deformation caused by the application of a prestressing
force?
Blowout
Cantilever
Creep
Camber - Answer Camber
Pg 2
Concrete must be at ________% of its full strength before pulling the tendons in post-tensioned
concrete
60%
80%
75%
55% - Answer 75%
Pg 8
High density polyethylene sheathing is what _______ are protected by
Tendons
Joints
Cap piles
Footings - Answer Tendons
Pg 13
What would be the best method to use for off-loading the post tensioning cable from a flatbed
truck?
Using a forklift to raise bundles with hooks
Chain through the center of the bundle
Nylon strap that cradles the coil by passing through the center of the bundle
Pick it up with backhoe forks - Answer Nylon strap that cradles the coil by passing through
the center of the bundle
Pg 27
, The maximum distance to cut back sheathing for the anchor is:
2"
1 1/2"
1"
3" - Answer 1"
Pg 32
If a tendon is stressed at both ends, what is the recommended length of tail to leave outside the
edge form at each end?
6"
8"
10"
12" - Answer 12"
Pg 32
If there are 5 tendons in a group, what is the maximum diameter for each tendon?
1 1/2"
1"
1/2"
2 1/2" - Answer 1/2"
Pg 34
What is the maximum number of 0.6" tendons allowed in a post-tension bundle?
6
3
4
5 - Answer 4
Pg 34
For small or medium openings, the clearance of tendons at a blockout should be at least ____"
4
6
5
3 - Answer 6