Anchor Installation and Inspection
Assessment – 2026/2027 Edition – Verified
Questions and Answers
Q: Minimum anchor spacing and edge distance, as well as minimum member thickness, must
comply with the values given
Answer
In the products ICC-ES Report
Q: The registered design professional in responsible charge and the engineers of record
involved in the design of the project are permitted to act as the
Answer
Approved Agency
Q: If reinforcing bars are encountered during drilling the correct action would be
Answer
Consulting with the EOR
Q: for adhesive anchors, the characteristics bond stresses and suitability for structural
applications are established by testing in accordance with
Answer
ACI 355.4
,Q: Special inspections and tests shall be required for proposal work that is, in the opinion of
the building official, unusual in its nature, as such, but not limited to
Answer
All of the above
Q: ACI 355.4, qualification of post installed adhesive anchors in concrete, is applicable to
anchors with a specified minimum embedment depth of
Answer
1 - 5/8 inches
Q: Proof loads are usually determined as a
Answer
Percentage of the anchor ultimate tensile strength
Q: True or False: The contractor is permitted to employ the approved agencies for special
inspection where the contractor is also the owner of the project?
Answer
True
, Q: The effective embedment depth, measure from the concrete surface to the deepest point at
which bond to the concrete is established is identified as
Answer
h subscript(ef)
Q: True or false: Powers PE1000+ epoxy adhesive are recognized for use to resist short-term
and long-term loads, including wind and earthquake loads, subject to conditions of the ICC-ES
Evaluation report?
Answer
True
Q: Short sections of anchor rods the have been burned or sawed are indictive of:
Answer
Incorrect embedment
Q: The elapsed time after mixing adhesive material components to onset of significant
chemical reaction as characterized by an increase in viscosity is
Answer
Gel Time
Q: Periodic and final inspection reports are required to be summited to the
Answer
Building official and engineer or architect of record