EXAM SPECIFICATIONS

Time Allocation: 2.5 Hours


Total Questions: 100 Questions on State Exam


Question Format: Multiple Choice with Rationales


Minimum Competency: 70% Required to Pass


Core Focus: Lab Safety, Analytical Methods, Instrumentation, Calculations




Indiana Chemical Laboratory Technician Exam Prep 2026-2027 Page 1

, Exam Overview & Content Outline

EXAM PURPOSE

Indiana Chemical Laboratory Technician certification covers analytical chemistry, laboratory safety,
instrumentation, quality control, and calculations. Based on ACS, OSHA, EPA, and Indiana
Department of Environmental Management (IDEM) standards for environmental, industrial, and
research laboratories.

CONTENT DISTRIBUTION

• Laboratory Safety & Regulations (25%) — OSHA Lab Standard, SDS, PPE, chemical hygiene,
waste disposal, EPA, IDEM

• Analytical Techniques & Wet Chemistry (25%) — Titrations, gravimetric, pH, conductivity,
sample prep, reagents

• Instrumentation (25%) — UV-Vis, AA, ICP, GC, HPLC, calibration, maintenance, troubleshooting

• Quality Control & Data Analysis (15%) — QC charts, accuracy, precision, LOD, LOQ, statistics,
documentation

• Chemical Calculations & Math (10%) — Molarity, dilutions, ppm/ppb, stoichiometry, significant
figures, unit conversions

QUESTION FORMAT & SCORING

Each item presents four options. Correct answers are highlighted in green with checkmark (✓).
Every question includes detailed rationale with chemical laboratory standards. Indiana/industry
requires 70% to pass technician exam.

STUDY STRATEGY

Master OSHA Lab Standard and chemical hygiene. Know titration calculations and molarity.
Understand instrument principles and calibration. Review QC procedures and statistics. Study waste
disposal per EPA/IDEM. Practice unit conversions and dilutions.

CURRICULUM ALIGNMENT

Questions reflect 2026-2027 standards: ACS guidelines, OSHA 29 CFR 1910.1450, EPA methods,
IDEM regulations, Standard Methods for Water/Wastewater, and GLP/GMP requirements.




Indiana Chemical Laboratory Technician Exam Prep 2026-2027 Page 2

, SECTION I: Laboratory Safety & Regulations
1. OSHA Laboratory Standard 29 CFR 1910.1450 requires:
A. No chemical hygiene plan
✓ B. Written Chemical Hygiene Plan (CHP)
C. Unlimited exposure
D. No PPE
Rationale: OSHA Lab Standard: Requires written Chemical Hygiene Plan (CHP) for labs using hazardous
chemicals. CHP includes SOPs, control measures, PPE, training, medical surveillance, chemical inventory,
waste disposal. Chemical Hygiene Officer designated. Annual review. Protects workers from chemical
exposure.


2. SDS Section 2 contains:
A. First aid measures
✓ B. Hazard identification
C. Physical properties
D. Disposal
Rationale: SDS 16 sections: 1-ID, 2-Hazards, 3-Composition, 4-First Aid, 5-Fire, 6-Accidental Release,
7-Handling/Storage, 8-Exposure Controls/PPE, 9-Physical/Chemical, 10-Stability, 11-Toxicology,
12-Ecological, 13-Disposal, 14-Transport, 15-Regulatory, 16-Other. Section 2: GHS pictograms, signal
word, hazard statements.


3. Acid spill in lab should be neutralized with:
A. Water only
✓ B. Sodium bicarbonate or commercial neutralizer, then water
C. Base directly
D. Organic solvent
Rationale: Acid spill: Neutralize with sodium bicarbonate (baking soda) or commercial spill kit, then absorb
and dispose as hazardous waste. Never add water to concentrated acid (exothermic). Base spill: citric acid
or commercial neutralizer. PPE required. Report per CHP.


4. Fume hood face velocity should be:
A. 10 fpm
✓ B. 80-120 fpm
C. 500 fpm
D. 0 fpm
Rationale: OSHA/ANSI: Fume hood face velocity 80-120 fpm (typically 100 fpm) with sash at operating
height. Tested annually. Too low = escape; too high = turbulence. Keep sash low, no blocking. Not for
storage. Verify airflow before use. Protects from inhalation.


5. Hazardous waste container must be labeled with:
A. No label



Indiana Chemical Laboratory Technician Exam Prep 2026-2027 Page 3

Información del documento

Subido en
29 de junio de 2026
Número de páginas
29
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$25.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
ExcellentExams
3.3
(4)
Vendido
19
Seguidores
2
Artículos
3516
Última venta
1 mes hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes