• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 2 fuera de 6 páginas
Examen

High Pressure Boilers Newest updated Final Exam with accurate answers

Document preview thumbnail
Vista previa 2 fuera de 6 páginas

High Pressure Boilers Newest updated Final Exam with accurate answers

Vista previa del contenido

2



High Pressure Boilers Newest updated Final Exam with accurate
|| || || || || || || || ||




answers


Boiler fittings are necessary for __________ - ✔✔- efficiency
|| || || || || || || ||




To prevent failure from pressure over the MAWP, all steam boilers must be equipped with at
|| || || || || || || || || || || || || || ||




least one __________ - ✔✔- safety valve
|| || || || || || ||




The purpose of a safety valve is to __________ - ✔✔- prevent the boiler from exceeding its
|| || || || || || || || || || || || || || || || ||




MAWP



Safety valves are designed to __________ - ✔✔- pop open
|| || || || || || || || ||




When testing a safety valve manually, there must be __________ - ✔✔- at least 75% of the
|| || || || || || || || || || || || || || || || ||




safety valve popping pressure on the boiler
|| || || || || ||




Any repairs to the safety valve must be done by the __________ - ✔✔- manufacturer-
|| || || || || || || || || || || || || ||




authorized representative ||




A __________ test is used to test the relief capacity of a safety valve - ✔✔- accumulation
|| || || || || || || || || || || || || || || ||




__________ pressure is the pressure caused by the weight of a column of water - ✔✔-
|| || || || || || || || || || || || || || || ||




hyrdrostatic



A cyclone separator is a cylindrical device that separates water droplets from steam using
|| || || || || || || || || || || || || ||




__________ - ✔✔- centrifugal force || || || ||

, 2


A steam pressure gauge must be protected by a siphon to prevent __________ - ✔✔- steam
|| || || || || || || || || || || || || || || ||




from damaging the gauge
|| || ||




The correction factor for hydrostatic pressure is __________ psi per vertical foot - ✔✔- .433
|| || || || || || || || || || || || || ||




The boiler vent is open when warming up a boiler until __________ - ✔✔- there is 10 psi to
|| || || || || || || || || || || || || || || || || || ||




25 psi of steam pressure on the boiler
|| || || || || || ||




Separators work on the basic principle of __________ - ✔✔- changing the direction of
|| || || || || || || || || || || || || ||




steam flow ||




The dry pipe separator is located in the __________ - ✔✔- upper part of the steam drum
|| || || || || || || || || || || || || || || ||




The ASME Code states that high pressure boilers in battery and equipped with manhole
|| || || || || || || || || || || || || ||




openings must have __________ - ✔✔- two main steam stop valves
|| || || || || || || || || ||




A main steam stop valve should be a __________ - ✔✔- os&y gate
|| || || || || || || || || || || ||




Boiler safety valves are placed at the highest part of the __________ - ✔✔- steam space
|| || || || || || || || || || || || || || ||




During boiler inspection, the main steam stop valves are __________ - ✔✔- closed, locked,
|| || || || || || || || || || || || || ||




and tagged ||




A pressure gauge must be recalibrated if it is not accurate to within __________% of the
|| || || || || || || || || || || || || || || ||




working pressure - ✔✔- 2 || || || ||




During normal usage, __________ are used to allow for the expansion and contraction of
|| || || || || || || || || || || || || ||




the main steam line - ✔✔- expansion bends
|| || || || || || ||

Información del documento

Subido en
22 de junio de 2026
Número de páginas
6
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$17.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Ruiz
3.2
(15)
Vendido
106
Seguidores
4
Artículos
14206
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes