Guide & Practice Questions 2026-2027
Comprehensive exam preparation resource for the Texas General Pump Installer licensing exam.
Covers pump installation, water systems, groundwater fundamentals, electrical components,
pressure tanks, piping systems, troubleshooting, safety regulations, maintenance procedures, and
Texas licensing requirements. Includes practice questions and answer explanations to help
candidates prepare for certification and professional practice in pump installation and water well
systems.
. Which specific component in a 3-wire single-phase control box
switches the start capacitor out of the circuit based on voltage
generated by the motor?
A. Thermal overload protector
B. Run capacitor
C. Potential starting relay
D. Magnetic contactor
Rationale: The potential relay monitors the back-electromotive force (back-EMF) voltage
generated across the start winding. Once the motor reaches approximately 75% of full
running speed, this voltage energizes the relay coil, opening the contacts to disconnect
the start capacitor.
2. Under TDLR regulations, what is the minimum required
distance that a water well casing must extend above the final
finished ground elevation or concrete floor?
A. 6 inches
B. 12 inches
C. 18 inches
D. 24 inches
Rationale: Texas Administrative Code (16 TAC §76) mandates that a well casing
terminate a minimum of 12 inches above the surrounding ground surface or pump
house floor to prevent surface water runoff from overwhelming the well head.
,3. What occurs if a bladder-type pressure tank is pre-charged
with air pressure while the entire plumbing system is fully
pressurized with water?
A. The pressure switch contacts will weld shut instantly.
B. The tank will have an inaccurate, insufficient air charge once the system is
drained.
C. The pump motor will spontaneously run in reverse at double speed.
D. The pressure relief valve will lock permanently in the open position.
Rationale: Measuring or adding air pre-charge against pressurized water distorts the
gauge reading due to hydraulic resistance. To get an accurate pre-charge setting, the
pump must be turned off and all water drained from the plumbing lines.
4. What chemical compound is most commonly utilized by
licensed pump installers to shock-chlorinate a newly serviced
residential well?
A. Hydrochloric acid
B. Sodium hypochlorite or Calcium hypochlorite
C. Aluminum sulfate
D. Copper sulfate crystals
Rationale: Sodium hypochlorite (liquid bleach) or calcium hypochlorite (granular or
tablets) are standard chlorine sources used to safely disinfect water systems and
eliminate bacterial contamination introduced during maintenance.
5. If a three-phase submersible well pump is running smoothly
but delivering significantly reduced flow and pressure, what is
the most likely cause?
A. The start capacitor inside the control box has completely failed.
B. The motor is spinning backward due to incorrect phase wiring.
C. The drop pipe diameter is slightly larger than specified.
D. The thermal overload protector has an open circuit.
,Rationale: Three-phase motors will operate in reverse rotation if any two of the three
incoming power leads are switched. A centrifugal pump running backward will still move
a small amount of water due to friction, but at drastically reduced efficiency, flow, and
head.
6. What structural hazard occurs if a high-horsepower
submersible pump is installed on a rigid PVC drop pipe string
without a torque arrestor?
A. The PVC pipe will soften and expand from high friction heat.
B. Rotational startup forces can unthread or snap the pipe joints downhole.
C. The pipe wall will suffer severe galvanic scale buildup.
D. The PVC will convert into a semi-porous filtration membrane.
Rationale: Submersible motors produce a counter-torque kick when starting from a
dead stop. Without a rubber torque arrestor to anchor the drop pipe against the casing,
this twisting motion can wear, fracture, or unthread pipe couplings over time.
7. What vertical distance is used to mathematically calculate the
"suction lift" of a surface-mounted centrifugal pump?
A. From the open water surface up to the center axis of the pump impeller
B. From the bottom of the well borehole to the pump intake screen
C. From the pitless adapter up to the pressure tank inlet port
D. From the static water table down to the lowest well screen section
Rationale: Suction lift is measured vertically from the top of the liquid water level up to
the center axis of the pump intake, representing the maximum physical height that
atmospheric pressure can push the fluid into the pump's vacuum.
8. What does a continuous, rapid clicking or "chattering" sound
coming out of a standard pressure switch indicate?
, A. The well pump has successfully reversed its rotation.
B. The pressure tank has failed or is completely waterlogged.
C. The control box starting relay is permanently locked open.
D. The system voltage has switched from AC to DC.
Rationale: When a pressure tank is waterlogged, it loses its compressible air cushion.
Because water cannot compress, the pressure spikes and drops instantly when the
pump turns on and off, causing the switch contacts to open and close rapidly.
9. Convert a system pressure gauge reading of 60 PSI into the
equivalent feet of water head.
A. 26.0 feet
B. 60.0 feet
C. 138.6 feet
D. 277.2 feet
Rationale: To convert pressure in PSI to feet of head, multiply the PSI reading by the
physical constant 2.31 (60 × 2.31 = 138.6 feet of head).
10. According to TDLR regulations, what is the minimum
mandatory horizontal separation distance between a private
water well and a septic tank?
A. 10 feet
B. 25 feet
C. 50 feet
D. 100 feet
Rationale: Texas state well construction standards dictate a strict minimum safety buffer
of 50 feet between a water well head and a septic tank to mitigate the risk of subsurface
bacterial migration.