A sprinkler is 3 feet away from a gas powered unit heater in a 2,000 square foot garage. What should be the temperature rating of the sprinkler? - ANSWER High temp 286 degrees In a new apartment building where the highest floor for use is 45 feet above the lowest level for fire department access, which type of standpipe is required? - ANSWER wet automatic What is the minimum fire-resistance rating for a fire partition that separates dwelling units in the same building that in constructed of Type VB (5B) construction and a sprinkler system in accordance with International Building Code (IBC) section 903.3.1.1 ? - ANSWER 1/2 hour per IBC 708.3 A contractor submits hydraulic calculations for a wet system with black steel pipe. The calculations are based on a C value of 120. The AHJ rejects the calculations because the local building code requires a value of 100 to be used for wet and dry systems. The contract requires the contractor to follow NFPA 13 and local building codes. What should the contractor do? - ANSWER Revise the calculation to comply with the local code requirements A 45000 square foot building with 40 feet of elevation to the roof has required exit stairways and a Class I manual dry standpipe system. A roof manifold is located 3 feet above the roof. The total amount of friction loss in the pipe is 8 psi. What is the required flow and pressure at the fire department connection (FDC) located 3 feet above finished grade? - ANSWER 750 gpm and 126 psi (2,480 liters per minute and 8.6 bar) A contract has been finalized to relocate upright sprinklers to the pendent position from an exis

Vista previa del contenido

Nicet Water Based Layout Level III EXAM
QUESTIONS AND ANSWERS 100% CORRECT!!

, Which detail is one purpose of architectural drawings? - ANSWER communicate scope
of work

For fire pump and jockey pump installations, where should the pump controller's
pressure sensing lines be connected? - ANSWER individual from each other

A sprinkler is 3 feet away from a gas powered unit heater in a 2,000 square foot garage.
What should be the temperature rating of the sprinkler? - ANSWER High temp 286
degrees

In a new apartment building where the highest floor for use is 45 feet above the lowest
level for fire department access, which type of standpipe is required? - ANSWER wet
automatic

What is the minimum fire-resistance rating for a fire partition that separates dwelling
units in the same building that in constructed of Type VB (5B) construction and a
sprinkler system in accordance with International Building Code (IBC) section
903.3.1.1 ? - ANSWER 1/2 hour per IBC 708.3

A contractor submits hydraulic calculations for a wet system with black steel pipe. The
calculations are based on a C value of 120. The AHJ rejects the calculations because
the local building code requires a value of 100 to be used for wet and dry systems. The
contract requires the contractor to follow NFPA 13 and local building codes. What
should the contractor do? - ANSWER Revise the calculation to comply with the local
code requirements

A 45000 square foot building with 40 feet of elevation to the roof has required exit
stairways and a Class I manual dry standpipe system. A roof manifold is located 3 feet
above the roof. The total amount of friction loss in the pipe is 8 psi. What is the required
flow and pressure at the fire department connection (FDC) located 3 feet above finished
grade? - ANSWER 750 gpm and 126 psi (2,480 liters per minute and 8.6 bar)

A contract has been finalized to relocate upright sprinklers to the pendent position from
an existing pipe schedule system that includes 3/4-inch ( 20 millimeter) pipe supplying 1
sprinkler. Which is the correct course of action? - ANSWER Replace 3/4-inch pipe with
1 inch use 1/2 nipples no longer than 4 inches, 1-by-1/2 reducing elbows, and new 1
inch drop pipe per NFPA 13 section 30.4.4

A sprinkler manufacturer has a proprietary listing on a sidewall sprinkler capable of a
28-foot-wide discharge spray pattern. Which sprinkler information (if noted on the

Información del documento

Subido en
2 de abril de 2026
Número de páginas
5
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$12.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Luckyexams
3.2
(6)
Vendido
30
Seguidores
2
Artículos
2288
Última venta
5 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes