NFPA 99 Med Gas TEST FINAL EXAM AND PRACTICE EXAM
20262027 BANK 2 VERSIONS QUESTIONS WITH DETAILED
VERIFIED ANSWERS EXAM QUESTIONS WILL COME
FROM HERE (100% CORRECT ANSWERS A+ GRADED




An existing system that is not in the strict compliance with the
provisions of this code shall be permitted to be continued in use as long
as _______ has determined that such use does not constitute a distinct
hazard to life. - ANSWER--Authority having jurisdiction


Cylinder and cryogenic liquid container outlet connections shall be
designed as to render the attachment point _______ when removal of
the outlet connection is attempted - ANSWER--Unusable


Cylinders in use and in storage shall be prevented from reaching
temperatures in excess of _____ F° - ANSWER--125


Nitrous oxide and carbon dioxide using cylinders or portable containers
shall be prevented from reaching temperatures lower than ______ F° -
ANSWER--20


Which system shall not be permitted to be located in an outdoor
enclosure? - ANSWER--Medical Air Sources

,2|Page




Indoor locations for Oxygen, Nitrous Oxide, and mixtures of these gases
shall not communicate with anything except? - ANSWER--Designated
storage area


Locations for Central supply systems shall have _______ devices
protected from physical damage. - ANSWER--Electrical


Outdoor locations surrounded by impermeable walls, except fire barrier
walls, shall have protected ventilation openings at the _______ of each
wall to allow free circulation of air within the enclosure. - ANSWER--
Base


All positive pressure supply systems shall be provided with duplex line
pressure regulators piped in _______. - ANSWER--Parallel


All pressure relief valves shall be made of brass, bronze or _______. -
ANSWER--Stainless steel


Central supply systems for positive pressure gases shall have one or
more relief valves, the valves shall have a relief setting that is _____%
above normal operating pressure. - ANSWER--50

,3|Page


When vented to the outside, relief valve vent lines shall be labeled in
which way? - ANSWER--Any manner that will distinguish them from the
medical gas pipeline


An auxiliary source connection shall consist of - ANSWER--Visual
pressure indicator


In central supply systems using gas or liquid cylinders, each header shall
have a ______ to prevent debris from entering the manifold controls. -
ANSWER--Filter


Manifolds for gas cylinders shall consist of two equal headers, each
header with enough cylinders for an average days supply, not not fewer
than ______ connections. - ANSWER--2


Manifolds for gas cylinders shall have a _____ signal that visibly
indicates the operating status of the equipment and shall activate an
indicator at all master alarm panels when or just before changeover
from one header to the other takes place. - ANSWER--Local


When multiple buildings are served from a single cryogenic liquid
oxygen source, it is required to place the emergency oxygen supply
connection in ______. - ANSWER--Each building served


The minimum clearance around EOSC for a temporary source of supply
is _______ ft. - ANSWER--3

, 4|Page




An ______ emergency reserve system can be substituted for the EOSC.
- ANSWER--In building


Nitrous oxide cylinders shall be prevented from reaching temperatures
in excess of. - ANSWER--125 degrees F


Carbon dioxide cylinders shall be prevented from reaching
tempertaures below. - ANSWER--20 degrees F


Central supply systems for positive pressure gasses shall have one or
more relief valves with the relief setting above nromal operating
pressure. - ANSWER--50%


Completed Manufactured Assesmblies being tested at 20% above
operating pressure shall not exceedthis percentage for leakage? -
ANSWER--0.5%


Activities , systems , or equipment whose failure is likely to cause major
injury or death of patients, staff, or visitors. - ANSWER--Category 1


Activities, systems, or equipment whose failure is likely to cause minor
injury to patients, staff, or visitors. - ANSWER--Category 2

Información del documento

Estudio
Subido en
19 de marzo de 2026
Número de páginas
49
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$37.60

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
2
Seguidores
1
Artículos
495
Última venta
4 meses hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes