Theory, Systems Types, Terminology & General Requirements (32%) • Fundamental principles of heating, ventilation, and air conditioning (HVAC) systems • Types of HVAC systems and their applications • Industry terminology and definitions • General requirements for HVAC installations 2. Refrigerant & Condensate Piping (12%) • Design and installation of refrigerant piping systems • Sizing and selection of refrigerant lines • Condensate drainage systems and their components • Maintenance and troubleshooting of refrigerant and condensate systems 3. Evaporators, Compressors, Condensers, Chillers, Cooling Towers, Heat Pumps, Heating & AC Appliances (10%) • Operation and maintenance of evaporators and compressors • Function and servicing of condensers and chillers • Cooling tower operations and maintenance • Heat pump systems and their applications • Installation and servicing of heating and air conditioning appliances 4. Conditioned Air, Supply, Return, Makeup, Combustion Air, Air Ducts, Dampers & Insulation (5%) • Design and installation of air distribution systems • Sizing and balancing of supply and return air ducts • Makeup and combustion air requirements • Installation and maintenance of dampers and insulation 5. Electrical Fundamentals & Controls (9%) • Basic electrical principles related to HVAC systems • Electrical components and their functions • Control systems and wiring diagrams • Troubleshooting electrical issues in HVAC systems 6. Refrigerants (12%) • Types and properties of refrigerants • Refrigerant handling and storage procedures • Leak detection and repair methods • Environmental regulations and safety standards 7. Operating Procedures, including Safety (12%) • Standard operating procedures for HVAC systems • Safety protocols and personal protective equipment (PPE) • Emergency response procedures • Regulatory compliance and industry standards 8. Maintenance & Repairs (8%) • Preventive maintenance practices • Diagnostic techniques for system malfunctions • Repair procedures for common HVAC components • Record-keeping and reporting requirements

Mostrar más Leer menos

Vista previa del contenido

District Of Columbia (DC)Journeyman
A/C & Refrigeration Exam 312: 312
Practice Questions & Study Guide
(2012 IMC)
Overview

The DC Journeyman A/C & Refrigeration License is a professional
credential issued by the District of Columbia Board of Industrial
Trades. It authorizes the holder to perform installation, maintenance,
and repair of air conditioning and refrigeration systems under the
supervision of a licensed Master Mechanic. This exam is designed to
ensure technicians understand the complex physics of refrigeration
cycles, electrical safety, and the legal requirements of
the International Mechanical Code (IMC).

Key Features

 Open Book Policy: You are permitted to use the 2012 International
Mechanical Code and Modern Refrigeration and Air
Conditioning during the test.
Major Topics: IMC Regulations, Refrigeration Cycle Theory,
Electrical Fundamentals, Troubleshooting, and Safety.

1. According to the 2012 IMC, what is the minimum required
thickness for a galvanized steel dryer exhaust duct?
A) 0.010 inch
B) 0.013 inch
C) 0.016 inch
D) 0.020 inch
Answer: C

,Rationale: IMC Section 504.6.1 requires dryer exhaust ducts to be a
minimum of 0.016 inches thick to withstand heat and prevent lint
accumulation in ridges.
2. A "Superheat" reading that is significantly higher than the
manufacturer’s recommendation usually indicates:
A) An overcharged system.
B) A starved evaporator.
C) A dirty condenser coil.
D) Non-condensables in the system.
Answer: B
Rationale: High superheat means the refrigerant has turned into vapor
too early in the evaporator and is picking up extra sensible heat, often
due to a low charge or restricted expansion valve.
3. In a 240V single-phase motor, if you measure resistance
between one terminal and the motor shell and get 0 Ohms, the
motor is:
A) Open.
B) Shorted to ground.
C) Running normally.
D) Under-loaded.
Answer: B
Rationale: Any continuity (0 or low resistance) between the electrical
windings and the metal frame indicates a "grounded" motor, which is a
severe safety hazard.
4. What is the specific gravity of R-22 liquid compared to water?
A) 0.5
B) 1.0
C) 1.2
D) 2.4
Answer: C
Rationale: Most HCFC and HFC refrigerants are slightly denser than
water, typically ranging around 1.1 to 1.3.
5. According to IMC Section 306.5, equipment installed on a roof
must be provided with a permanent ladder if the roof is more
than _____ feet above grade.

,A) 10 feet
B) 12 feet
C) 15 feet
D) 20 feet
Answer: C
Rationale: For safety and accessibility, the code requires a permanent
means of access (ladder) for roof heights exceeding 15 feet.
6. Which component is responsible for changing low-pressure
vapor into high-pressure vapor?
A) Condenser
B) Evaporator
C) Compressor
D) Accumulator
Answer: C
Rationale: The compressor is the "heart" of the system; it creates the
pressure difference necessary for the refrigerant to flow and change
state.
7. A "Centrifugal" compressor is most commonly found in:
A) Residential window units.
B) Large commercial water chillers.
C) Household refrigerators.
D) Reach-in coolers.
Answer: B
Rationale: Centrifugal compressors are designed for high-volume,
low-pressure applications, making them ideal for large-scale industrial
cooling.
8. The 2012 IMC states that a condensate drain line must not be
smaller than _____ inch.
A) 1/2 inch
B) 3/4 inch
C) 1 inch
D) 1-1/4 inch
Answer: B
Rationale: Per IMC 307.2.1, 3/4 inch is the minimum internal diameter
required to prevent clogs from sludge and algae.

, 9. "Total Heat" in the refrigeration cycle is also known as:
A) Entropy.
B) Latent heat.
C) Enthalpy.
D) Sensible heat.
Answer: C
Rationale: Enthalpy measures the total heat content of a substance
(sensible + latent) and is used to plot the refrigeration cycle on a
Mollier chart.
10. When installing a TXV, where should the sensing bulb be
located on a 7/8" suction line?
A) Bottom of the pipe (6 o’clock position).
B) Top of the pipe (12 o’clock position).
C) Side of the pipe (4 or 8 o’clock position).
D) Inside the evaporator coil.
Answer: C
Rationale: On lines 7/8" and larger, placing the bulb at 4 or 8 o’clock
ensures it reads the temperature of the vapor and not any liquid
oil/refrigerant sitting at the bottom.
11. According to the IMC, what is the maximum length allowed
for a flexible air duct?
A) 5 feet
B) 8 feet
C) 14 feet
D) No limit
Answer: C
Rationale: IMC 603.6.1.1 restricts flexible air ducts to a maximum of
14 feet to prevent excessive friction loss and sagging.
12. A "Start Capacitor" is removed from the circuit by the:
A) Thermostat.
B) Contactor.
C) Centrifugal switch or potential relay.
D) Circuit breaker.
Answer: C
Rationale: Once the motor reaches roughly 75% of its rated speed, a

Información del documento

Subido en
13 de marzo de 2026
Número de páginas
51
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$31.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
studyguidepro NURSING
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
257
Miembro desde
10 meses
Número de seguidores
12
Documentos
2298
Última venta
18 horas hace
verified exams

Updated exams .Actual tests 100% verified.ATI,NURSING,PMHNP,TNCC,USMLE,ACLS,WGU AND ALL EXAMS guaranteed success.Here, you will find everything you need in NURSING EXAMS AND TESTBANKS.Contact us, to fetch it for you in minutes if we do not have it in this shop.BUY WITHOUT DOUBT!!!!Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied. **Ace Your Exams with Confidence!**

3.6

49 reseñas

5
21
4
4
3
13
2
5
1
6

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes