All the following are required parts of an atmospheric vacuum breaker (asse1001) except a Air inlet float valve The body Air canopy Shutoff valve - ANSWERShutoff valve A single check valve for a backflow prevention is acceptable For low hazard For non-hazard residential applications On boilers only Never - ANSWERNever The following absolute pressure could cause backsiphonage to occur in a hydraulic system (distribution system) at sea level

Voorbeeld van de inhoud

BACKFLOW FINAL QUESTIONS &
SOLUTIONS(RATED A+)
All the following are required parts of an atmospheric vacuum breaker (asse1001)
except a

Air inlet float valve

The body

Air canopy

Shutoff valve - ANSWERShutoff valve

A single check valve for a backflow prevention is acceptable

For low hazard

For non-hazard residential
applications

On boilers only

Never - ANSWERNever

The following absolute pressure could cause backsiphonage to occur in a hydraulic
system (distribution system) at sea level

10.5 psia

15.0 psia

33.9 psia

100 psia - ANSWER10.5 psia

It is the recommended that double check backflow prevention assembly (asse 1015) be
installed with its lowest point a minimum of

Six inches from wall

Twelve inches from highest point of use

Twelve inches above the surrounding ground or floor

,Thirty inches above the surrounding ground or floor - ANSWER12 inches above
surrounding floor

When testing a double check valve backflow prevention assembly (asse1015) number
two shutoff valve must be closed first to

Prevent backpressure during the test

Prevent backsiphonage during the test

Hold water in the downstream piping

Maintain pressure in the assembly - ANSWERMaintain pressure in the assembly

Which of the following should be considered when installing a cross connection control
device or assembly?

Sidewall clearances

Degree of hazard

Distance of backflow device
from floor

All above - ANSWERAll above

Backflow can occur whenever the pressure in a potable water system is ______ the
pressure in a non potable piping system and the two systems are physically connected

Greater than

Less than

Equal to

About same as - ANSWERLess than

The required number of test cocks on a two inch and smaller pressure vacuum breaker
assembly (asse 1020) is

None

One

Two

, Three - ANSWERTwo

The springs on the two check valves of a reduced pressure principle backflow preventer
(asse 1013) are

Identical

Externally loaded

Not interchangeable

Interchangeable - ANSWERNot interchangeable

The spring relief valve assembly of a reduced pressure principle backflow preventer
(asse 1013) acts to

Force the relief valve open

Force the relief valve closed

Force the first check valve open

Force the first check valve closed - ANSWERForce the relief valve closed

Reduced pressure principle backflow preventer (asse 1013) shall not be installed in a
vertical position unless

It is an existing water service

The water pressure exceeds 160 psi

It is a pit instillation

The assembly has been tested and approved for installation in a vertical position -
ANSWERThe assembly has been tested and approved for installation in a vertical
position

The type of protection provided by an air gap separation is

Backsiphonage low hazard

Backpreassure low hazard

Backpreassure high and low hazard

Documentinformatie

Geüpload op
12 februari 2026
Aantal pagina's
19
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden
$12.49

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kan je een ander document kiezen. Je kan het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
shantelleG
4.0
(118)
Verkocht
649
Volgers
369
Items
18317
Laatst verkocht
21 uur geleden



Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen