BACKFLOW FINAL QUESTIONS & SOLUTIONS(RATED A+)

Puntuación
-
Vendido
-
Páginas
19
Grado
A+
Subido en
12-02-2026
Escrito en
2025/2026

All the following are required parts of an atmospheric vacuum breaker (asse1001) except a Air inlet float valve The body Air canopy Shutoff valve - ANSWERShutoff valve A single check valve for a backflow prevention is acceptable For low hazard For non-hazard residential applications On boilers only Never - ANSWERNever The following absolute pressure could cause backsiphonage to occur in a hydraulic system (distribution system) at sea level

Mostrar más Leer menos
Institución
Backflow Prevention Troubleshooting
Grado
Backflow prevention troubleshooting

Vista previa del contenido

BACKFLOW FINAL QUESTIONS &
SOLUTIONS(RATED A+)
All the following are required parts of an atmospheric vacuum breaker (asse1001)
except a

Air inlet float valve

The body

Air canopy

Shutoff valve - ANSWERShutoff valve

A single check valve for a backflow prevention is acceptable

For low hazard

For non-hazard residential
applications

On boilers only

Never - ANSWERNever

The following absolute pressure could cause backsiphonage to occur in a hydraulic
system (distribution system) at sea level

10.5 psia

15.0 psia

33.9 psia

100 psia - ANSWER10.5 psia

It is the recommended that double check backflow prevention assembly (asse 1015) be
installed with its lowest point a minimum of

Six inches from wall

Twelve inches from highest point of use

Twelve inches above the surrounding ground or floor

,Thirty inches above the surrounding ground or floor - ANSWER12 inches above
surrounding floor

When testing a double check valve backflow prevention assembly (asse1015) number
two shutoff valve must be closed first to

Prevent backpressure during the test

Prevent backsiphonage during the test

Hold water in the downstream piping

Maintain pressure in the assembly - ANSWERMaintain pressure in the assembly

Which of the following should be considered when installing a cross connection control
device or assembly?

Sidewall clearances

Degree of hazard

Distance of backflow device
from floor

All above - ANSWERAll above

Backflow can occur whenever the pressure in a potable water system is ______ the
pressure in a non potable piping system and the two systems are physically connected

Greater than

Less than

Equal to

About same as - ANSWERLess than

The required number of test cocks on a two inch and smaller pressure vacuum breaker
assembly (asse 1020) is

None

One

Two

, Three - ANSWERTwo

The springs on the two check valves of a reduced pressure principle backflow preventer
(asse 1013) are

Identical

Externally loaded

Not interchangeable

Interchangeable - ANSWERNot interchangeable

The spring relief valve assembly of a reduced pressure principle backflow preventer
(asse 1013) acts to

Force the relief valve open

Force the relief valve closed

Force the first check valve open

Force the first check valve closed - ANSWERForce the relief valve closed

Reduced pressure principle backflow preventer (asse 1013) shall not be installed in a
vertical position unless

It is an existing water service

The water pressure exceeds 160 psi

It is a pit instillation

The assembly has been tested and approved for installation in a vertical position -
ANSWERThe assembly has been tested and approved for installation in a vertical
position

The type of protection provided by an air gap separation is

Backsiphonage low hazard

Backpreassure low hazard

Backpreassure high and low hazard

Escuela, estudio y materia

Institución
Backflow prevention troubleshooting
Grado
Backflow prevention troubleshooting

Información del documento

Subido en
12 de febrero de 2026
Número de páginas
19
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

  • backflow
$12.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF


Documento también disponible en un lote

Thumbnail
Package deal
BACKFLOW PREVENTION STUDY GUIDE (CHARLESTON WATER SYSTEMS)CORRECT 100% COMPLETE EXAM BUNDLE
-
13 2026
$ 170.37 Más información

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
shantelleG West Virgina University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
625
Miembro desde
3 año
Número de seguidores
369
Documentos
18110
Última venta
2 semanas hace
GOLD PREMIUM

HELLO? welcome to my store thanks for visiting this page here you are guaranteed of well revised and assured EXAMS ALL GRADED A+ thus making your education journey easy and seamless . DO NOT HESITATE TO CONTACT ME IF YOU ARE IN NEED OF ANY EXAM .I AM READY 24/7 TO ASSIST YOU ALSO REFER YOUR FRIENDS.

4.0

118 reseñas

5
69
4
11
3
24
2
2
1
12

Documentos populares

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes