Given: Two separate Services are identical in voltage and amperage, except that one service
serves only motor - loads and the other serves lighting loads only.
in the event of a short circuit in these services, the available short circuit current will be:
A) The same in either service
B) Higher in the motor-load service
C) Higher in the lighting -load service
D) 25% greater in the service for the motor load - ANSWER The same in either
service
(general knowledge)
A device that requires a portable ladder for access, but does NOT require removal of the
structure, is defined as being?
A) Accessible
B) Unaccessible
C) Simi- accessible
2
, D) Readily accessible - ANSWER Accessible
(article 100)
Which of the following is a multi - wire branch circuit?
A) Multiple conductors made up in the form of a cable
B) Conductors used to connect the non - current - carrying metal parts of appliances
C) A circuit that direct connects the service equipment to the main circuit breaker
D) A circuit that consists of two or more ungrounded conductors and a grounded conductor -
ANSWER A circuit that consists of two or more ungrounded conductors and a
grounded conductor.
(article 100)
A listed assembly of two , three, or four insulated circuit conductors within a NONMETALLIC
jacket, an extruded thermoplastic covering, or a sealed nonmetallic covering that can be
mounted directly on the surface of walls and ceilings is the definition for:
A) Flat conductor cable
B) Flat cable assemblies
C) Nonmetallic sheath cable
D) Concealable nonmetallic extension - ANSWER Concealable nonmetallic extension
(article 382.2)
3
CORRECT = 100
100
INCORRECT=0
STUDY MATERIALS.......DESIGNED TO HELP YOU SUCCEED
SPOTLIGHT 1
1
, CORRECT WELL DETAILED ANSWERS|LATEST
UPDATE!!!!!!2026|GUARANTEED PASS|GRADED
Given: Two separate Services are identical in voltage and amperage, except that one service
serves only motor - loads and the other serves lighting loads only.
in the event of a short circuit in these services, the available short circuit current will be:
A) The same in either service
B) Higher in the motor-load service
C) Higher in the lighting -load service
D) 25% greater in the service for the motor load - ANSWER The same in either
service
(general knowledge)
A device that requires a portable ladder for access, but does NOT require removal of the
structure, is defined as being?
A) Accessible
B) Unaccessible
C) Simi- accessible
2
, D) Readily accessible - ANSWER Accessible
(article 100)
Which of the following is a multi - wire branch circuit?
A) Multiple conductors made up in the form of a cable
B) Conductors used to connect the non - current - carrying metal parts of appliances
C) A circuit that direct connects the service equipment to the main circuit breaker
D) A circuit that consists of two or more ungrounded conductors and a grounded conductor -
ANSWER A circuit that consists of two or more ungrounded conductors and a
grounded conductor.
(article 100)
A listed assembly of two , three, or four insulated circuit conductors within a NONMETALLIC
jacket, an extruded thermoplastic covering, or a sealed nonmetallic covering that can be
mounted directly on the surface of walls and ceilings is the definition for:
A) Flat conductor cable
B) Flat cable assemblies
C) Nonmetallic sheath cable
D) Concealable nonmetallic extension - ANSWER Concealable nonmetallic extension
(article 382.2)
3