Which refrigerant is considered a high-pressure refrigerant? correct answers R-410A

Department of Transportation (DOT) regulations require the ________ to be recorded on the
shipping paper for hazard class 2.2 Nonflammable Compressed Gases. correct answers number
of cylinders of each gas

________ contains chlorine. correct answers R-22

During servicing of any refrigeration system, the refrigerant must be ________. correct answers
recovered

After proper R-410A refrigerant recovery, you should use ________ to leak check the system.
correct answers nitrogen, and if a trace gas is desired, add a small amount of R-410A

The ability of a substance to destroy ozone in the stratosphere is referred to as ________. correct
answers ODP (ozone depletion potential)

Ozone contains ________. correct answers molecules containing 3 oxygen atoms

All CFC, HCFC, and HFC refrigerant recovery devices must ________. correct answers meet
EPA standards

A system is considered dehydrated when ________. correct answers a micron-gauge shows you
have reached and held a vacuum of 500 microns or less with the vacuum pump isolated from the
system

If there is a large release of refrigerant in a contained area ________. correct answers leave the
area, and return with self-contained breathing apparatus

Ester-based oils like POE can be mixed with ________. correct answers no other oils

Never fill a refillable refrigerant cylinder beyond ________. correct answers 80% of its capacity
by weight

When a system using POE oil has been opened, what is the minimum evacuation level that
should be achieved and held before charging the system? correct answers 500 microns

f corrosion is discovered in the body of a relief valve, the valve must be ________. correct
answers replaced

After a refrigerant is phased-out, supplies of that refrigerant for equipment servicing can only
come from ________. correct answers recovered and reclaimed refrigerant

, ________ means that the refrigerant blend has a range of bubble or dew points at a constant
pressure. correct answers Temperature glide

Always ________ when operating refrigerant recovery or recycling equipment. correct answers -
Wear safety glasses
- Wear Protective Gloves
- Follow all safety precautions (for the equipment)
"All of the Above"

The capacity of a vacuum pump and its suction line size affect ________. correct answers
moisture removal and evacuation time

Never operate a hermetic compressor when the system ________. correct answers is evacuated

Which refrigerant release is illegal? correct answers Venting refrigerant from an approved dual-
refrigerant recovery machine to switch working fluids.

Which material is NOT compatible with any HFO refrigerant? correct answers Silicone

The Department of Transportation (DOT) requires ________ when transporting cylinders
containing used refrigerant. correct answers DOT classification tags

When measuring a vacuum of the system, the vacuum gauge should be connected ________.
correct answers to the system as far as possible away from the vacuum pump

How should disposable cylinders be discarded? correct answers Recover all remaining
refrigerant, render the cylinders useless, and recycle the metal.

When a system is operating, the ________ changes a low-pressure vapor to a high-pressure
vapor. correct answers compressor

Which of the following synthetic lubricants is used with ternary refrigerant blends containing
HCFCs? correct answers Alkylbenzene

Non-toxic refrigerants can still cause death because ________. correct answers they are heavier
than air and can cause asphyxia

Under the EPA's new regulations, when can disposable cylinders be used to recover refrigerant?
correct answers Never.

An example of an HCFC refrigerant is: correct answers R-123

A system containing a flammable refrigerant must have the process tubes or service connection
marked with a color marking that extends a minimum of ________ in both directions. correct
answers 1 inch

Información del documento

Subido en
30 de enero de 2026
Número de páginas
7
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$11.39

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
SirAnton
3.7
(118)
Vendido
807
Seguidores
438
Artículos
40068
Última venta
3 semanas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes