100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

NORA TEST QUESTIONS & VALID CORRECT ANSWERS PASSED 100%

Puntuación
-
Vendido
-
Páginas
5
Grado
A+
Subido en
18-01-2026
Escrito en
2025/2026

NORA TEST QUESTIONS & VALID CORRECT ANSWERS PASSED 100% is a study resource designed to help learners prepare for exams related to auxiliary burner systems commonly used in industrial boilers, furnaces, and thermal processing equipment. It summarizes key concepts, definitions, and operational principles in an easy-to-review flashcard format.

Mostrar más Leer menos
Institución
NORA
Grado
NORA









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NORA
Grado
NORA

Información del documento

Subido en
18 de enero de 2026
Número de páginas
5
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NORA TEST QUESTIONS & VALID
CORRECT ANSWERS PASSED 100%

The key final adjustment for most oil burners is - CORRECT ANSWER combustion air

The high static air pressure created by todays oil burner - CORRECT ANSWER Enable
boiler and furnaces to have tighter more efficient heat

Dirt or lint build-up in the bevel of the burner fan blades will? - CORRECT ANSWER
Reduce the amount of combustion air

How do high pressure atomizing oil burners light oil on fire? - CORRECT ANSWER
They pressurize the oil to turn it from a liquid to droplets, mix them with air, then heat
the droplets until they vaporize then ignite

To change the air ratio for different firing rates with an adjustable head burner you? -
CORRECT ANSWER Adjust the position of the drawer assembly in the Air tube

When burned one gallon of #2 oil releases approximately? - CORRECT ANSWER
140,000 BTU's

The pour point of #2 oil is? - CORRECT ANSWER The lowest temperature at which oil
will flow

Sulfuric acid in combustion gasses can? - CORRECT ANSWER Create scale buildup
in the heat exchanger

Flash point of a fuel is an indication of? - CORRECT ANSWER The lowest temperature
at which it will flash but not continue to burn

As heating oil gets colder its viscosity (thickness)? - CORRECT ANSWER increases

A tank without a vent alarm - CORRECT ANSWER Should not be filled

What is the most common source of water in oil tanks? - CORRECT ANSWER
condensation

The home for bacterial growth and sludge in the bottom of the oil tank is? - CORRECT
ANSWER water

Pumping the old oil from a tank being replaced into the new tank? - CORRECT
ANSWER Is ok as long as you do not pump the last 50 gallons from the tank bottom

, Fuel units (oil pumps) perform the following function? - CORRECT ANSWER Move oil
from the tank to the burner and deliver it at a constant regulated pressure to the nozzle

The best way to clear a clogged oil line is to? - CORRECT ANSWER Use a hand pump
to suck the blockage out

If the oil level in the tank is 4 foot below and 10 feet away from the fuel unit and the filter
is new the approximate vacuum should be? - CORRECT ANSWER 5 to 6 inches

If the operating vacuum is significantly less than the calculated vacuum you probably
have? - CORRECT ANSWER A Suction line leak

If the operating vacuum reading is significantly above the calculated vacuum you
probably have? - CORRECT ANSWER A clogged oil filter

It is best to connect fuel units as a one-pipe system instead of two-pipe because? -
CORRECT ANSWER One pipe leads to longer filter life and eliminates worries about
leaking return lines

A cause of pulsating oil pump pressure and pulsating fire is? - CORRECT ANSWER Air
leaks in the suction line

A fuel de-aerator? - CORRECT ANSWER Eliminates the need for a return line back to
the oil tank

The flow rate stamped on the nozzle is based on? - CORRECT ANSWER 100 PSI

The purpose of an oil burner nozzle is to? - CORRECT ANSWER Atomize and meter
the oil

Nozzle after drip can be caused by? - CORRECT ANSWER Thermal expansion of the
oil in the drawer assembly after shut down

To reduce combustion problems caused by cold oil? - CORRECT ANSWER Increase
the pump pressure and reduce the nozzle size

Increasing the fuel pressure pump will? - CORRECT ANSWER Increase the flow rate

A proper combustion chamber - CORRECT ANSWER Is large enough so the fire
doesn't impinge on any surface

How are draft and combustion air related? - CORRECT ANSWER As negative draft
over-the- fire increases the combustion air drawn into the burner increases
$11.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
STUVIA2024
5.0
(1)

Conoce al vendedor

Seller avatar
STUVIA2024 Chamberlain College Nursing
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
5
Miembro desde
8 meses
Número de seguidores
0
Documentos
5524
Última venta
1 semana hace

5.0

1 reseñas

5
1
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes