What is balance point in a heat pump? - CORRECT ANSWER -When the capacity, BTU, is the
same rate as the heat loss of a structure.




Do electric air cleaners remove odors? - CORRECT ANSWER -No




When should a suction line accumulator be used in a residential heat pump? - CORRECT
ANSWER -Only when recommended by the manufacturer if long refrigerant lines increase
system charge over recommended maximum charge.




The measurement of a heat pumps efficiency is often stated using its "Coefficient of
Performance" or COP. What is the COP (Coefficient of Performance)of a heat pump? - CORRECT
ANSWER -Heat pumps heat output (watts) divided by its total electrical input (watts)




What is a benefit in using electronic air cleaner? - CORRECT ANSWER -Indoor Air Quality (IAQ)
quality is improved.



What is the thermal balance point of a dual fuel heat pump? - CORRECT ANSWER -Outdoor
conditions at which the capacity of auxiliary heat alone matches the heating load.

,What is the minimum circuit amp listed on a units' data plate is used to determine? - CORRECT
ANSWER -The max fuse or circuit breaker size.




How are heat pumps particularly sized? - CORRECT ANSWER -Based on the cooling load.




What is an effective method of reducing sound when AHU is located in a closet? - CORRECT
ANSWER -Use Vibration isolators.




When wiring a 20 amp FLA motor what is the minimum amp fuse or circuit breaker that should
be used? - CORRECT ANSWER -25amp




How is the typical staging of a two stage HP system determined? - CORRECT ANSWER -Use the
deviation of the t-stat setting to determine when to engage each stage.




What is the purpose of a sequencer in a HP with an AUX 20 kW electric heater? - CORRECT
ANSWER -Energize one or two elements and the blower then energize the other elements in
timed intervals.




In a HP (heat pump) circuit what is used to by-pass refrigerant flow around the metering device?
- CORRECT ANSWER -An open check valve.

, What is the most commonly used type of fan in residential systems? - CORRECT ANSWER -The
forward curve centrifugal fan.




When is condensation on vapor lines a concern?when the lines are routed inside a wall. -
CORRECT ANSWER -When lines are routed inside a wall.




In a single zone system; if a customer complains of feeling damp or sticky the cause could be
what? - CORRECT ANSWER -Unconditioned air being pulled into the duct work through holes in
the duct.




When performing indoor air balancing tests how should the t-stat should be set? - CORRECT
ANSWER -Should be set to bring on the indoor fan on mid-high speed.




Most manufacturers recommend what size t-stat wire? - CORRECT ANSWER -The smallest most
allowable, 18AWG (All Weather Gauge)




Where should you check voltage input to a compressor? - CORRECT ANSWER -At the load side
of the contactor.




HP (Heat Pump) unit; 1st and 2nd stage appear to be calling, compressor runs but not electric
heater, what is the problem? - CORRECT ANSWER -Second stage is open.

Información del documento

Subido en
18 de enero de 2026
Número de páginas
28
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$15.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Examchemist
4.3
(3)
Vendido
26
Seguidores
0
Artículos
3854
Última venta
6 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes