Boiler Exam Practice Tests (NEW UPDATED VERSION) LATEST
ACTUAL EXAM QUESTIONS AND CORRECT ANSWERS (VERIFIED
QUESTIONS AND ANSWERS)- GUARANTEED PASS A+ UPDATED 2026
removes sludge and sediment from the mud drum - CORRECT ANSWER
The bottom blowdown on a boiler ___.
QUESTION : outside diameter - CORRECT ANSWER Boiler tubes are
sized using the ___.
QUESTION : tin - CORRECT ANSWER A boiler fusible plug is brass or
bronze with a core of ___.
QUESTION : hairline cracks in the refractory - CORRECT ANSWER
Spalling in a boiler refers to ___.
QUESTION : 34.5 - CORRECT ANSWER Boiler horsepower is the
evaporation of ___ lb of water/hr from and at a feedwater temperature of 212°F.
QUESTION : steam temperature - CORRECT ANSWER A siphon
installed between the boiler and the pressure gauge protects the Bourdon tube
from___.
2026 2027 GRADED A+
,2|Page
QUESTION : 10 to 11.5 - CORRECT ANSWER The pH of the boiler
water should be ___.
QUESTION : steam leaving the boiler - CORRECT ANSWER The
boiler superheater raises the temperature of the ___.
QUESTION : feedwater - CORRECT ANSWER An economizer is used
to preheat ___.
QUESTION : oily waste rags - CORRECT ANSWER Fires caused by
spontaneous combustion would probably start in the ___.
QUESTION : dirty strainers - CORRECT ANSWER A high suction
reading on the fuel oil pressure gauge indicates ___.
QUESTION : try cock - CORRECT ANSWER The ___ is a secondary
means of determining boiler water level.
QUESTION : pyrometer - CORRECT ANSWER A(n) ___ is used to
measure furnace temperature.
QUESTION : 1 ½ - CORRECT ANSWER The range of a boiler pressure
gauge must not be less than ___ times the safety valve setting.
QUESTION : prevent formation of scale - CORRECT ANSWER Boiler
feedwater is chemically treated to ___.
2026 2027 GRADED A+
,3|Page
QUESTION : deadweight tester - CORRECT ANSWER Pressure
gauges are calibrated with a(n) ___.
QUESTION : inside tube surface - CORRECT ANSWER In a firetube
boiler, soot settles on the ___.
QUESTION : complete - CORRECT ANSWER Carbon dioxide in the
flue gas is a sign of ___ combustion.
QUESTION : incomplete - CORRECT ANSWER Carbon monoxide in
the flue gas is a sign of ___ combustion.
QUESTION : Globe - CORRECT ANSWER ___ valves should be used
for throttling service.
QUESTION : a dirty heating surface - CORRECT ANSWER A gradual
increase in chimney temperature indicates ___.
QUESTION : 1 ½ - CORRECT ANSWER The pressure applied on the
boiler during a hydrostatic test is ___ times the MAWP.
QUESTION : 6 - CORRECT ANSWER Boiler safety valve capacity must
be such that the steam pressure can never go higher than ___% above the
MAWP.
2026 2027 GRADED A+
, 4|Page
QUESTION : decreased - CORRECT ANSWER As fuel oil is heated, its
viscosity is ___.
QUESTION : 6 - CORRECT ANSWER No. ___ fuel oil has the highest
Btu content per gallon.
QUESTION : T - CORRECT ANSWER T/F All steam boilers must have
one or more safety valves.
QUESTION : T - CORRECT ANSWER T/F An open feedwater heater
vents gases to the atmosphere.
QUESTION : F - CORRECT ANSWER T/F A hydrostatic test will
determine whether a steam boiler has sufficient relieving capacity.
QUESTION : T - CORRECT ANSWER T/F When boilers are set in
battery, the main steam stop valves, bottom blowdown valves, and feedwater
valves should be locked closed before anyone enters the boiler drums.
QUESTION : F - CORRECT ANSWER T/F Open and closed feedwater
heaters are never used at the same time.
QUESTION : T - CORRECT ANSWER T/F In an open feedwater heater,
the water and steam come into direct contact; in a closed feedwater heater, the
water and steam are separated.
2026 2027 GRADED A+