NCC Practice Test 5 Questions and
Answers 2026
twoBjunctionBboxesBareBeachBlocatedBonBdifferentBwalls,B12BinchesBfromBtheBsameBcorner.BG
ivenBaB90*BbendBwithBaBtake-upBofB6BinchesBandBaBgainB2-
1/4Binches,BwhatBisBtheBdevelopedBlengthBofBtheBconduitBbetweenBthem?B-BAnswer21B3/4"
WhichBofBtheBfollowingBisBmostBcommonlyBusedBtoBcutBRMCBandBIMC?B-BAnswerpipeBcutter
WhichBofBtheBfollowingBtypesBofBtransformersBcanBbeBventilated,Bair-cooled,BorBsealed?B-
BAnswerDry-typeBtransformers
BeforeBstartingBaBcableBpull,BmakeBsureBthatB-
BAnswerallBcommunicationsBequipmentBisBinBworkingBorder
WhenBperformingBthermographicBsurveys,BaBmajorBdeficiencyBisBindicatedBbyBaBgradientBofB-
BAnswer16*BC
TheBvoltageBimbalanceBtripBpointBforBaBprogrammableBsolid-
stateBoverloadBrelayBisBtypicallyBsetBforB-BAnswer5%
TheBbasicBpurposeBofBswitchgearBisBtoB-
BAnswerprovideBpowerBsystemBprotectionBbyBautomaticallyBisolatingBfaultyBcomponents
TheBlineBvoltagesBinBaBYBconnectionBareB-
BAnswer1.732BtimesBhigherBthanBtheBphaseBvoltages
ABtransformerBcanBbeBcheckedBforBshortedBturnsBusingBaB-BAnswerTTRBtester
ABtypicalBhand-crankBwireBpuller,BusingB30BpoundsBofBforce,BcanBpullBupBtoB-
BAnswer1500Bpounds
AccordingBtoBtheBNEC,BneutralBconductorsBsizeBNo.B6BandBsmallerBmustBhaveBaBcontinuousB
markingBofBwhiteBorB-BAnswergray
, ABdeviceBthatBisBusedBtoBstepBupBgeneratedBvoltageBtoBmakeBitBsuitableBforBcommercialBtra
nsmissionBisBcalledBaB-BAnswerpowerBtransformer
WhichBofBtheBfollowingBprovidesBaBcurvedBsurfaceBforBtheBcableBtoBfollowBasBitBpassesBfrom
BtheBtray?B-BAnswerdropoutBplate
CapacitorsBareBcoveredBinB-BAnswerNECBArticleB460
AnBSSOLRBinitiatesBaBtripBifBtheBphaseBcurrentsBexceedBwhatBpercentageBofBtheBtripBcurrent
BdialBsetting?B-BAnswer125%
TheBresistanceBofBswitchgearBshouldBbeBcheckedBusingBaB-BAnswer1000VBmegger
SymbolsBusedBtoBshowBcableBtrayBsystemsBonBworkingBdrawingsBareBexplainedBinBtheB-
BAnswerlegend
WhichBofBtheBfollowingBisBanBNECBrequirementsBforBgroundingBandBbondingBcableBtrayBinstal
lations?B-BAnswerSteelBorBaluminumBtraysBmayBbeBusedBasBequipmentBgroundingBconductors
ABdownedBpowerBlineBisBmostBlikelyBtoBresultBinBaB-BAnswerphaseBfailure
WhenBdoesBanBoff-delayBrelayBprovideBtheBtimeBdelay?B-BAnswerAfterBtheBrelayBisBde-
energized
MostBcontrolBtransformersBareB-BAnswerdry-typeBstep-down
SpecialtyBstep-downBtransformersBareBoftenB-
BAnswerusedBforBsmallBwork,BsuchBasBdoorbellsBandBotherBsignalingBsystems
InBaBpotentialBtransformer,BtheBvoltageBacrossBtheBsecondaryBterminalsBisBalwaysB-
BAnswerlowerBthanBtheBprimaryBvoltage
Answers 2026
twoBjunctionBboxesBareBeachBlocatedBonBdifferentBwalls,B12BinchesBfromBtheBsameBcorner.BG
ivenBaB90*BbendBwithBaBtake-upBofB6BinchesBandBaBgainB2-
1/4Binches,BwhatBisBtheBdevelopedBlengthBofBtheBconduitBbetweenBthem?B-BAnswer21B3/4"
WhichBofBtheBfollowingBisBmostBcommonlyBusedBtoBcutBRMCBandBIMC?B-BAnswerpipeBcutter
WhichBofBtheBfollowingBtypesBofBtransformersBcanBbeBventilated,Bair-cooled,BorBsealed?B-
BAnswerDry-typeBtransformers
BeforeBstartingBaBcableBpull,BmakeBsureBthatB-
BAnswerallBcommunicationsBequipmentBisBinBworkingBorder
WhenBperformingBthermographicBsurveys,BaBmajorBdeficiencyBisBindicatedBbyBaBgradientBofB-
BAnswer16*BC
TheBvoltageBimbalanceBtripBpointBforBaBprogrammableBsolid-
stateBoverloadBrelayBisBtypicallyBsetBforB-BAnswer5%
TheBbasicBpurposeBofBswitchgearBisBtoB-
BAnswerprovideBpowerBsystemBprotectionBbyBautomaticallyBisolatingBfaultyBcomponents
TheBlineBvoltagesBinBaBYBconnectionBareB-
BAnswer1.732BtimesBhigherBthanBtheBphaseBvoltages
ABtransformerBcanBbeBcheckedBforBshortedBturnsBusingBaB-BAnswerTTRBtester
ABtypicalBhand-crankBwireBpuller,BusingB30BpoundsBofBforce,BcanBpullBupBtoB-
BAnswer1500Bpounds
AccordingBtoBtheBNEC,BneutralBconductorsBsizeBNo.B6BandBsmallerBmustBhaveBaBcontinuousB
markingBofBwhiteBorB-BAnswergray
, ABdeviceBthatBisBusedBtoBstepBupBgeneratedBvoltageBtoBmakeBitBsuitableBforBcommercialBtra
nsmissionBisBcalledBaB-BAnswerpowerBtransformer
WhichBofBtheBfollowingBprovidesBaBcurvedBsurfaceBforBtheBcableBtoBfollowBasBitBpassesBfrom
BtheBtray?B-BAnswerdropoutBplate
CapacitorsBareBcoveredBinB-BAnswerNECBArticleB460
AnBSSOLRBinitiatesBaBtripBifBtheBphaseBcurrentsBexceedBwhatBpercentageBofBtheBtripBcurrent
BdialBsetting?B-BAnswer125%
TheBresistanceBofBswitchgearBshouldBbeBcheckedBusingBaB-BAnswer1000VBmegger
SymbolsBusedBtoBshowBcableBtrayBsystemsBonBworkingBdrawingsBareBexplainedBinBtheB-
BAnswerlegend
WhichBofBtheBfollowingBisBanBNECBrequirementsBforBgroundingBandBbondingBcableBtrayBinstal
lations?B-BAnswerSteelBorBaluminumBtraysBmayBbeBusedBasBequipmentBgroundingBconductors
ABdownedBpowerBlineBisBmostBlikelyBtoBresultBinBaB-BAnswerphaseBfailure
WhenBdoesBanBoff-delayBrelayBprovideBtheBtimeBdelay?B-BAnswerAfterBtheBrelayBisBde-
energized
MostBcontrolBtransformersBareB-BAnswerdry-typeBstep-down
SpecialtyBstep-downBtransformersBareBoftenB-
BAnswerusedBforBsmallBwork,BsuchBasBdoorbellsBandBotherBsignalingBsystems
InBaBpotentialBtransformer,BtheBvoltageBacrossBtheBsecondaryBterminalsBisBalwaysB-
BAnswerlowerBthanBtheBprimaryBvoltage