POWER ENGINEERING 3A2 EXAM 2026
FINAL PAPER SOLVED QUESTIONS
ACCURATE ANSWERS
⫸ According to the Regulations, valves, gauges and regulating or
controlling devices attached to the boiler are called
A) fittings.
B) pipework.
C) auxiliary equipment
D) Controllers
E) Auxiliaries Answer: A
⫸ The primary purpose of boiler and pressure vessel legislation is to
A) specify boiler design parameters.
B) generate revenues for the government.
C) license power engineers.
D) safeguard life and property.
E) reduce plant operating costs. Answer: D
⫸ According to the Regulations, a power engineer who is in charge of a
plant under the supervision of a chief engineer is called the
A) shift engineer.
B) relief engineer.
, C) assistant engineer.
D) shift operator.
E) assistant chief engineer. Answer: A
⫸ Regulatory authorities may select and test, at the manufacturer's
expense, any registered fitting designed under the CSA B51 Code.
A) True.
B) False. Answer: A
⫸ A boiler drum is made of SA-515-70 steel and has a ligament
efficiency of 0.66. If the steam temperature is 280oC, the inside
diameter of the drum is 1.6 m and the drum thickness is 74.27 mm, what
will be the maximum operating pressure in kPa?
A) 2500 kPa
B) 3850 kPa
C) 7893 kPa
D) 10 280 kPa
E) 11 960 kPa Answer: C
FINAL PAPER SOLVED QUESTIONS
ACCURATE ANSWERS
⫸ According to the Regulations, valves, gauges and regulating or
controlling devices attached to the boiler are called
A) fittings.
B) pipework.
C) auxiliary equipment
D) Controllers
E) Auxiliaries Answer: A
⫸ The primary purpose of boiler and pressure vessel legislation is to
A) specify boiler design parameters.
B) generate revenues for the government.
C) license power engineers.
D) safeguard life and property.
E) reduce plant operating costs. Answer: D
⫸ According to the Regulations, a power engineer who is in charge of a
plant under the supervision of a chief engineer is called the
A) shift engineer.
B) relief engineer.
, C) assistant engineer.
D) shift operator.
E) assistant chief engineer. Answer: A
⫸ Regulatory authorities may select and test, at the manufacturer's
expense, any registered fitting designed under the CSA B51 Code.
A) True.
B) False. Answer: A
⫸ A boiler drum is made of SA-515-70 steel and has a ligament
efficiency of 0.66. If the steam temperature is 280oC, the inside
diameter of the drum is 1.6 m and the drum thickness is 74.27 mm, what
will be the maximum operating pressure in kPa?
A) 2500 kPa
B) 3850 kPa
C) 7893 kPa
D) 10 280 kPa
E) 11 960 kPa Answer: C