100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

IAHCSMM ENDOSCOPIC COMPREHENSIVE EXAM UPDATED QUESTIONS AND SOLUTIONS RATED A+

Puntuación
-
Vendido
-
Páginas
19
Grado
A+
Subido en
04-01-2026
Escrito en
2025/2026

IAHCSMM ENDOSCOPIC COMPREHENSIVE EXAM UPDATED QUESTIONS AND SOLUTIONS RATED A+

Institución
IAHCSMM ENDOSCOPIC
Grado
IAHCSMM ENDOSCOPIC










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
IAHCSMM ENDOSCOPIC
Grado
IAHCSMM ENDOSCOPIC

Información del documento

Subido en
4 de enero de 2026
Número de páginas
19
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

IAHCSMM ENDOSCOPIC COMPREHENSIVE EXAM UPDATED
QUESTIONS AND SOLUTIONS RATED A+
✔✔True or false? Adding more high-level disinfectant to the soak basin or automated
equipment reprocessor to bring the solution up the desired level also extends the length
of time the solution can be used. - ✔✔False

✔✔True or false? Automated endoscopes reprocessor device connectors are designed
for use with any flexible endoscope. - ✔✔False

✔✔True or false? When using an automated equipment reprocessor with an automated
cleaning cycle, it is still necessary to thoroughly manually clean the endoscope before
using the automated cycle. - ✔✔True

✔✔Automated equipment reprocessors should be quality tested: - ✔✔At least weekly

✔✔True or false? Water bottles can be processed in any automated equipment
reprocessor. - ✔✔False

✔✔The following should be documented each time an item is high-level disinfected: -
✔✔Name or initials of the person performing the high-level disinfection, minimum
effective concentration, and date and time the high-level disinfection process took place

✔✔The high-level disinfectant solution in an automated equipment reprocessor should
be tested for the minimum effective concentration: - ✔✔Before each use

✔✔True or false? Most multi-part flexible endoscopes and their accessories must be
disassembled for sterilization. - ✔✔True

✔✔True or false? When the color of chemical indicator tape used to seal flat wrap
changes, it indicates that the item is sterile. - ✔✔False

✔✔True or false? Gas plasma sterilizers must be in an area physically separated from
all other work areas. - ✔✔False

✔✔The Occupational Safety and Health Administration requires a method to alert
employees to emergency situations for this type of low-temperature sterilizers: -
✔✔Ethylene oxide

✔✔Items being prepared for ethylene oxide sterilization should be - ✔✔Clean, dry, and
compatible with ethylene oxide

,✔✔True or false? All flexible endoscopes should have a ventilation adapter or water-
resistant cap in place when undergoing ethylene oxide sterilization. - ✔✔False

✔✔True or false? An effective way to dry endoscopes before ethylene oxide sterilization
is to use heated forced air. - ✔✔False

✔✔True or false? Peel pouches are an acceptable package material for ethylene oxide
sterilization. - ✔✔True

✔✔True or false? When running an ethylene oxide sterilizer, the load should be full,
unless there is a medical necessity to run a partially filed load. - ✔✔True

✔✔True or false? A biological indicator should be run in each ethylene oxide cycle. -
✔✔True

✔✔When carrying flexible endoscopes, they should always be held at the - ✔✔Control
head

✔✔To prevent cross-contamination when handling a contaminated endoscope, it is
important to use: - ✔✔Directional workflow, personal protective equipment, and proper
signage

✔✔When valves are placed back on a flexible endoscope for storage - ✔✔They trap
moisture and facilitate microbial growth.

✔✔True or false? Flexible endoscope components that have been removed for cleaning
should always be kept with the same endoscope because they will be easier to track. -
✔✔True

✔✔True or false? Endoscopes should always be stored vertically. - ✔✔False

✔✔True or false? Filtered air is used to help reduce the risk for contamination during
storage. - ✔✔True

✔✔True or false? When storing flexible endoscopes, the terms "expiration date" and
"hang time" mean the same thing. - ✔✔True

✔✔Flexible endoscopes that have received high-level disinfection should be
reprocessed after a hang time of - ✔✔Time should be determined by each facility.

✔✔The process of identifying all risks to and from an activity and assigning the potential
impact of each risk is called - ✔✔Risk assessment

, ✔✔Sterilized flexible endoscopes should be stored - ✔✔In the same manner as other
sterilized devices

✔✔Arthroscopes are used for surgeries on - ✔✔Joints

✔✔True or false? The objective lens of a rigid endoscope is the strongest part of the
endoscope. - ✔✔False

✔✔Rod lenses of a rigid endoscope are made from - ✔✔Glass

✔✔The ocular lens of a rigid endoscope is - ✔✔The closest lens to the eye

✔✔Rigid endoscope lens damage can easily occur from - ✔✔Dropping, bending, and
exposure to excessive heat

✔✔True or false? Some rigid endoscopes have an operative channel. - ✔✔True

✔✔When using a rigid endoscope, a dark image may be caused by damaged: -
✔✔Illumination fibers, coupler, or camera

✔✔True or false? Although rigid endoscope light cords come in different sizes, they
may be used with any size rigid endoscope. - ✔✔False

✔✔An advantage of video imaging is: - ✔✔The light source does not overheat, the
surgical team can see the operative site, and they provide three-dimensional image

✔✔True or false? Cables used to transmit laser light are the same as cables used to
transmit non-laser light. - ✔✔False

✔✔Endoscope equipment maintenance management systems should include polices
on: - ✔✔Equipment safety, inspection, and planned maintenance

✔✔True or false? Surveyors may ask staff in the endoscope reprocessing area to
demonstrate department protocols for damaged endoscopes. - ✔✔True

✔✔This department is responsible for providing input into the endoscope use and
handling system: - ✔✔Reprocessing, infection prevention, and user

✔✔Endoscope leak testing can identify the following problem with a flexible endoscope
- ✔✔O-rings that are not properly seated

✔✔True or false? During leak testing, an increase in pressure when moving the elevator
levers indicates a leak in the system. - ✔✔False
$12.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
BOARDWALK Havard School
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
182
Miembro desde
1 año
Número de seguidores
7
Documentos
24136
Última venta
5 días hace
BOARDWALK ACADEMY

Ace Your Exams With Top Quality study Notes And Paper✅✅ ALL ACADEMIC MATERIALS AVAILABLE WITH US✅✅ LEAVE A REVIEW SO THAT WE CAN LOOK AND IMPROVE OUR MATERIALS.✅✅ WE ARE ALWAYS ONLINE AND AVAILABLE DONT HESITATE TO CONTACT US FOR SYUDY GUIDES!!✅✅ EVERYTHING IS GRADED A+✅✅ COLOUR YOUR GRADES WITH US , WE ARE HERE TO HELP YOU DONT BE RELACTANT TO REACH US

3.7

33 reseñas

5
14
4
6
3
7
2
0
1
6

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes