What are the requirements of toilet room doors in period b and period c
facilities? ---------CORRECT ANSWER-----------------Resident toilet room doors shall
be not less than 3 feet by 6'8" and shall not swing into the toilet room unless they
are provided with two-way hardware
What must emergency electrical service cover? ---------CORRECT ANSWER-----------
------Lighting at nursing stations, telephone switchboards, exit and corridor lights,
boiler room, fire alarm systems, and medical records when solely electronically
based.
The emergency power system may be battery operated if it is effective for how
long? ---------CORRECT ANSWER-----------------At least 4 hours
What type of water supply shall be maintained at all times? ---------CORRECT
ANSWER-----------------A potable water supply
,The temperature of hot water at plumbing fixtures used by resident may not
exceed the range of what temp? ---------CORRECT ANSWER-----------------110-115
degrees F
Which period facilities shall have night lighting? ---------CORRECT ANSWER-----------
------Period C
In period C facilities, all rooms in which food is stored, prepared or served, or in
which utensils are washed shall be well-ventilated. Do you refrigerated storage
rooms need to be ventilated? ---------CORRECT ANSWER-----------------No
In period B facilities, at least on elevator shall be provided when residents' beds
are located on one more floors above or below the dining or service floor. What
shall the platform size of the elevator be? ---------CORRECT ANSWER-----------------
Large enough to hold a resident bed and attendant
In period B and C facilities, what type of outlet shall be provided for every
resident's bed? ---------CORRECT ANSWER-----------------At least on duplex-type
outlet
No bedroom housing a resident shall open directly to? ---------CORRECT ANSWER--
---------------A kitchen or laundry
,How much space shall be between beds? ---------CORRECT ANSWER-----------------At
least 3 feet
A clear aisle space of at least ___ feet from the entrance to the room to each bed
shall be provided. ---------CORRECT ANSWER-----------------3
Closets or lockers shall afford a space of not less than? ---------CORRECT ANSWER--
---------------15 inches wide by 18 inches deep by 5 feet in height
All lavatories shall have hot and cold running water. Toilets shall be water flushed
and equipped with open front seats without ____? ---------CORRECT ANSWER-------
----------lids
Utility room requirements for period A, period B, and period C facilities. ---------
CORRECT ANSWER------------------Period A nursing homes shall have a utility room
that shall be located, designed and equipped to provide areas for the separate
handling of clean and soiled linen, equipment and supplies.
-Period B nursing homes shall have a ventilated utility room with a flush-rim
service sink
-Period C-- central location of soiled utility rooms is not required in existing
nursing homes
, Which period nursing homes shall have a nourishment station with sink, hot and
cold running water, refrigerator and storage for serving between-meal
nourishment if a kitchen is not open at all times? ---------CORRECT ANSWER---------
--------Period C
How much area may a nourishment station serve? ---------CORRECT ANSWER-------
----------Nourishment stations may serve more than one nursing area but not more
than a single floor
Dietary areas shall comply with? ---------CORRECT ANSWER-----------------The local
health or food handling codes
If on-site construction above the foundation is not started within ___ months of
the date of approval of the working plans the approval shall be void. ---------
CORRECT ANSWER-----------------6
What is a "basic nursing course"? ---------CORRECT ANSWER-----------------A course
or combination of courses that contain the basic nursing skills, competencies and
knowledge that the department is satisfied are generally equivalent in content to
the skills