100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS

Beoordeling
-
Verkocht
-
Pagina's
76
Cijfer
A+
Geüpload op
14-11-2025
Geschreven in
2025/2026

ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS

Instelling
ARRT RADIOGRAPHY
Vak
ARRT RADIOGRAPHY











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
ARRT RADIOGRAPHY
Vak
ARRT RADIOGRAPHY

Documentinformatie

Geüpload op
14 november 2025
Aantal pagina's
76
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS
LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL
ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS

The target angle of the anode allows for a ________ actual focal spot, while producing a ________
effective focal spot. This effect is known as the ________. - CORRECT ANSWERS 1) Larger

2) Smaller

3) Line Focus Principle



The target angle may be ________ to ________ degrees, depending on the tube design. - CORRECT
ANSWERS 1) 7

2) 20



When electrons travel from the cathode to the anode, they travel at up to ________ the speed of
________. - CORRECT ANSWERS 1) Half

2) Light



When electrons strike the anode, the kinetic energy converts the electrons into ________ and
________. - CORRECT ANSWERS 1) Heat

2) X-Rays



When striking the anode, the electron conversion to heat is approximately ________%. - CORRECT
ANSWERS 99.8



When striking the anode, the electron conversion to x-rays is approximately ________%. - CORRECT
ANSWERS 0.2



________ are a calculation of the total heat produced during an x-ray exposure. - CORRECT
ANSWERS Heat Units



Heat units for single-phase full-wave rectified equipment is calculated via this formula: - CORRECT
ANSWERS kVp x mAs

,ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS
LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL
ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS

Heat units for three-phase, six-pulse full-wave rectified equipment is calculated via this formula: -
CORRECT ANSWERS kVp x mAs x 1.35



Heat units for three-phase, twelve-pulse full-wave rectified equipment is calculated via this formula: -
CORRECT ANSWERS kVp x mAs x 1.41



The x-ray tube for fluoroscopy is operated at ________ to ________ mA. - CORRECT ANSWERS
1) 3

2) 5



kVp and mAs are automatically adjusted during fluoroscopy by a process known as ________. -
CORRECT ANSWERS Automatic Brightness Control (ABC)



Automatic brightness control is also called ________ or ________. - CORRECT ANSWERS 1)
Automatic Brightness Stabilization

2) Automatic Gain Control



The ________ receives exit rays from the patient and converts then into visible light. - CORRECT
ANSWERS Input Phosphor



Visible light from the input phosphor strikes the ________, which is a thin layer next to the input
phosphor. - CORRECT ANSWERS Photocathode



The photocathode releases electrons in amounts ________ proportional to the visible light striking it. -
CORRECT ANSWERS Directly



Electrons from the photocathode are concentrated and directed toward the other end of the image-
intensifier tube by a series of ________ and by ________ kVp applied through the tube. - CORRECT
ANSWERS 1) Electrostatic Lenses (Focusing Lenses)

2) 25

,ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS
LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL
ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS


Once electrons are propelled across the tube from the photocathode, they strike the ________. -
CORRECT ANSWERS Output Phosphor



Once the energy of the electrons hits the output phosphor, it is converted by the phosphor to ________
in amounts ________ to ________ times greater than the photocathode. - CORRECT ANSWERS
1) Visible Light

2) 50

3) 75



The increase in brightness from the photocathode to the output phosphor is known as ________. -
CORRECT ANSWERS Flux Gain



The ________ phosphor is smaller than the ________ phosphor, resulting in an increase in brightness
known as ________. - CORRECT ANSWERS 1) Output

2) Input

3) Minification Gain



Total brightness gain is a product of ________ gain and ________ gain. - CORRECT ANSWERS 1)
Minification

2) Flux



Total brightness gain ranges from ________ to ________, and decreases as the tube ages. - CORRECT
ANSWERS 1) 5000

2) 20000



A complete program in a radiology department that addresses all aspects of quality, including customer
service, image interpretation, accuracy of diagnosis, and distribution of radiologists' reports is known as:
- CORRECT ANSWERS Quality Assurance

, ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS
LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL
ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS

A program that specifically addresses the safe and reliable operation of equipment is known as: -
CORRECT ANSWERS Quality Control



A quality control program is required by ________. - CORRECT ANSWERS The Joint Commission



Collimation must be accurate to within ________% of the source-to-image receptor distance. -
CORRECT ANSWERS 2



The effective focal spot size should be within ________% of the size stated in the equipment
specifications. - CORRECT ANSWERS 50



kVp must be accurate to within ________% of the kVp indicated. - CORRECT ANSWERS 10



The exposure timer should be accurate to within ________% of the time chosen for exposures over 10
ms. - CORRECT ANSWERS 5



Adjacent mA stations should be accurate to within ________% of one another. This is known as
________. - CORRECT ANSWERS 1) 10

2) Exposure Linearity



Radiation intensity of sequential exposures should not vary more than ________%. This is known as
________. - CORRECT ANSWERS 1) 5

2) Exposure Reproduceability



The fluoroscopy exposure rate should be tested with a digital dosimeter, and should not be more
than________ per minute. - CORRECT ANSWERS 100 mGyᵃ



CR plates should be erased at least every ________. - CORRECT ANSWERS 48 Hours

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
bestScience Chamberlain College Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
74
Lid sinds
3 jaar
Aantal volgers
61
Documenten
3647
Laatst verkocht
1 maand geleden

3,2

9 beoordelingen

5
3
4
2
3
0
2
2
1
2

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen