100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

Michigan Journeyman EXAM STUDY GUIDE 2026 COMPLETE QUESTIONS WITH CORRECT DETAILED ANSWERS || 100% GUARANTEED PASS <RECENT VERSION>

Beoordeling
-
Verkocht
-
Pagina's
68
Cijfer
A+
Geüpload op
13-11-2025
Geschreven in
2025/2026

Michigan Journeyman EXAM STUDY GUIDE 2026 COMPLETE QUESTIONS WITH CORRECT DETAILED ANSWERS || 100% GUARANTEED PASS &lt;RECENT VERSION&gt; 1. There are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 70 amp load using THHM conductors. The minimum size conductors used our #_________AWG - ANSWER 4 2. Thermal insulation shall not be installed within _________inches of recessed lighting fixtures - ANSWER 3 3. A 1 inch conduit contains three wire circuits or a phase system. All conductors are number 10 TW. Each circuit consist of two phase conductors and one grounding conductor and one equipment grounding conductor. The maximum and pasty of each phase conductor is______. - ANSWER 24 amps 4. The volt Ampere rating of a device that consumes 14.5 A on a 240 V circuit is_____. - ANSWER 3480watts 5. A 208 V, three phase heater draws 3598 W . How many campers does the heater draw - ANSWER 10 6. The underwater light fixture shall be installed at least ________inches below the water level - ANSWER 18 7. A general purpose receptacle shall not be installed on the_________ - ANSWER Offense directly south of the pool 8. A junction box for a 124 wet niche fixture shall be at least_______Inches above the ground - ANSWER 4 9. A GFCI protected_______ receptacle for the pump motor May be installed on the south side of the dwelling unit dedicated grounding type - ANSWER Dedicated receptacle 10. A metal fence installed within________Feet of a pool Shall be bonded - ANSWER 5 11. The feed to the wet niche fixture shall be installed in - ANSWER Rigid brass 12. A 15 or 20 amp receptacle Shall be located within_____Feet of a rooftop air conditioner - ANSWER 25 13. In a commercial building the minimum size ungrounded service entrance conductor for 120 Dash 240 V single phase 200 amp service is - ANSWER 3/0 thwn copper 14. The minimum service for a one family dwelling Shall be - ANSWER 100amps 1. Where PV system DC circuits are run inside a building, they shall be contained in metal raceways,____ or metal enclosures from the point of penetration of the surface of the building to the readily accessible disconnecting means. - ANSWER Type MC cable 690.31.G 2. Unless specifically listed and marked for the location, the coupling means of the electric vehicle supply equipment shall be stored or located at a height of not less than___ inches above the grade level for outdoor locations. - ANSWER 24' 625.50 3. Unless specifically listed and marked for the location, the coupling means of the electric vehicle supply equipment shall be stored or located at a height of not less than___ inches above the floor level for indoor locations. - ANSWER 18" 625.50 4. All 15 and 20 ampere, 125 volt non locking type receptacles installed in the vehicle washing area of a carwash shall be listed and so identified as___ type. - ANSWER weather resistant 406.9.B1 5. All 15 and 20 ampere, 125 volt non locking type receptacles installed in the vehicle washing area of a carwash shall have an enclosure that is____ whether or not the attachment plug cap is inserted - ANSWER weather proof 406.9.B 6. An individual, other than an individual who is licensed under this article and___ and working under the direction of a holder of an electrical contractor's license, shall not in any manner undertake to execute any electrical wiring. - ANSWER employed by PA.407 339.5737 7. The ratio of electrical journeyman or master electricians to registered apprentice electricians shall be on the basis of___ electrical journeyman or master electricians to no more than___ registered apprentice electricians. - ANSWER 1 to 3 PA.407 339.5717 sec 717.3 8. Who can obtain a sign specialty contractor's license? - ANSWER an individual whom holds a sign specialist license 9. Where fuses rated___ amperes or higher are installed, the fuse shall have a clearing time of 0.07 seconds or less at the available arcing current. - ANSWER 1200amps 240.67.B 10. A meeting room that is at least 12 feet wide and has a floor area of at least 215 square feet shall have at least___ receptacle outlet(s) located in the floor at a distance not less than 6 feet from any fixed wall for each 215 square feet or major portion of floor space. - ANSWER 1 210.71.B2

Meer zien Lees minder
Instelling
Michigan Journeyman
Vak
Michigan Journeyman











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Michigan Journeyman
Vak
Michigan Journeyman

Documentinformatie

Geüpload op
13 november 2025
Aantal pagina's
68
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Michigan Journeyman EXAM STUDY
GUIDE 2026 COMPLETE QUESTIONS WITH
CORRECT DETAILED ANSWERS ||
100% GUARANTEED PASS
<RECENT VERSION>


1. There are six conductors in a race way connected to 75° C rated circuit
breaker. Each wire has a 70 amp load using THHM conductors. The
minimum size conductors used our #_________AWG - ANSWER ✔ 4


2. Thermal insulation shall not be installed within _________inches of
recessed lighting fixtures - ANSWER ✔ 3


3. A 1 inch conduit contains three wire circuits or a phase system. All
conductors are number 10 TW. Each circuit consist of two phase conductors
and one grounding conductor and one equipment grounding conductor. The
maximum and pasty of each phase conductor is______. - ANSWER ✔ 24
amps


4. The volt Ampere rating of a device that consumes 14.5 A on a 240 V circuit
is_____. - ANSWER ✔ 3480watts

,5. A 208 V, three phase heater draws 3598 W . How many campers does the
heater draw - ANSWER ✔ 10


6. The underwater light fixture shall be installed at least ________inches below
the water level - ANSWER ✔ 18


7. A general purpose receptacle shall not be installed on the_________ -
ANSWER ✔ Offense directly south of the pool


8. A junction box for a 124 wet niche fixture shall be at least_______Inches
above the ground - ANSWER ✔ 4


9. A GFCI protected_______ receptacle for the pump motor May be installed
on the south side of the dwelling unit dedicated grounding type - ANSWER
✔ Dedicated receptacle


10.A metal fence installed within________Feet of a pool Shall be bonded -
ANSWER ✔ 5


11.The feed to the wet niche fixture shall be installed in - ANSWER ✔ Rigid
brass


12.A 15 or 20 amp receptacle Shall be located within_____Feet of a rooftop air
conditioner - ANSWER ✔ 25

,13.In a commercial building the minimum size ungrounded service entrance
conductor for 120 Dash 240 V single phase 200 amp service is - ANSWER
✔ 3/0 thwn copper


14.The minimum service for a one family dwelling Shall be - ANSWER ✔
100amps


1. Where PV system DC circuits are run inside a building, they shall be
contained in metal raceways,____ or metal enclosures from the point of
penetration of the surface of the building to the readily accessible
disconnecting means. - ANSWER ✔ Type MC cable 690.31.G


2. Unless specifically listed and marked for the location, the coupling means of
the electric vehicle supply equipment shall be stored or located at a height of
not less than___ inches above the grade level for outdoor locations. -
ANSWER ✔ 24' 625.50


3. Unless specifically listed and marked for the location, the coupling means of
the electric vehicle supply equipment shall be stored or located at a height of
not less than___ inches above the floor level for indoor locations. -
ANSWER ✔ 18" 625.50


4. All 15 and 20 ampere, 125 volt non locking type receptacles installed in the
vehicle washing area of a carwash shall be listed and so identified as___
type. - ANSWER ✔ weather resistant 406.9.B1

, 5. All 15 and 20 ampere, 125 volt non locking type receptacles installed in the
vehicle washing area of a carwash shall have an enclosure that is____
whether or not the attachment plug cap is inserted - ANSWER ✔ weather
proof 406.9.B


6. An individual, other than an individual who is licensed under this article
and___ and working under the direction of a holder of an electrical
contractor's license, shall not in any manner undertake to execute any
electrical wiring. - ANSWER ✔ employed by PA.407 339.5737


7. The ratio of electrical journeyman or master electricians to registered
apprentice electricians shall be on the basis of___ electrical journeyman or
master electricians to no more than___ registered apprentice electricians. -
ANSWER ✔ 1 to 3 PA.407 339.5717 sec 717.3


8. Who can obtain a sign specialty contractor's license? - ANSWER ✔ an
individual whom holds a sign specialist license


9. Where fuses rated___ amperes or higher are installed, the fuse shall have a
clearing time of 0.07 seconds or less at the available arcing current. -
ANSWER ✔ 1200amps 240.67.B


10.A meeting room that is at least 12 feet wide and has a floor area of at least
215 square feet shall have at least___ receptacle outlet(s) located in the floor
at a distance not less than 6 feet from any fixed wall for each 215 square feet
or major portion of floor space. - ANSWER ✔ 1 210.71.B2

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
ProfBenjamin Havard School
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
433
Lid sinds
1 jaar
Aantal volgers
14
Documenten
3013
Laatst verkocht
4 uur geleden
EXCELLENT ACHIEVERS LIBRARY

As a professional tutor, I provide exceptional assistance with homework, quizzes, and exams across various subjects, including Psychology, Nursing, Biological Sciences, Business, Engineering, Human Resource Management, and Mathematics. I am dedicated to offering high-quality support and ensuring that all work meets scholarly standards. To enhance the effectiveness of our services, I work with a team of experienced tutors to create comprehensive and effective revision materials. Together, we are committed to helping students achieve excellent grades through our collaborative efforts and expertise.

Lees meer Lees minder
3,8

82 beoordelingen

5
36
4
12
3
24
2
4
1
6

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen