100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Extinguisher Exam Exam Questions and Answers 100% Pass |Already Graded A+| Verified and Updated |Actual 2025/2026 Cheat Sheet

Beoordeling
-
Verkocht
-
Pagina's
6
Cijfer
A+
Geüpload op
24-10-2025
Geschreven in
2025/2026

Extinguisher Exam Exam Questions and Answers 100% Pass |Already Graded A+| Verified and Updated |Actual 2025/2026 Cheat Sheet

Instelling
PTA
Vak
PTA









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
PTA
Vak
PTA

Documentinformatie

Geüpload op
24 oktober 2025
Aantal pagina's
6
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Extinguisher Exam
Study online at https://quizlet.com/_hu5v02

1. The dining area of a college cafeteria is classified as what type of hazard: Or-
dinary (moderate) Hazard
2. A loaded stream charged fire extinguisher with a stainless shell may remain
in service: True
3. A stored-Pressure water extinguisher with a brass shell join by rivets must be
removed from service.: True
4. The office area of a medical clinic is classified as what type of hazard: Light (low)
Hazard
5. A dry chemical fire extinguisher with a brass shell with brazed seams must be
removed from service: True
6. A church is classified as what type of hazard: Light (low) Hazard
7. ANSI/UL 629, is the standard for 2 1/2 gallon stored-pressure, water type fire
extinguishers: False
8. The documents that are referenced in chapter 2 of NFPA 10 ARE TO BE
CONSIDERED PART OF THE REQUIREMENTS OF NFPA 10: True
9. The compressed gas association Pamphlet CGA C-1, Methods of Hydro-static
Pressure of compressed Gas Cylinders, is considered a part of NFPA 10: True
10. Chapter 3 list various documents that are referenced through out NFPA
10: False
11. Dry chemical extinguisher agents usually contain additives to prevent pack-
ing and moisture absorption: True
12. Wet chemical is a chemical additive that materially reduces the surface
tension of water, increasing its penetrating and spreading characteristics.: False
13. There are two types of hydrogenated agents referenced in NFPA 10: halo-car-
bons and halons: True
14. A loaded stream charged refers to: Water-based extinguisher with an alkali metal as a freezing
point depressant
15. There are two types of film-forming form agents referenced in NFPA 10:
aqueous film-forming fluoroprotein foam.: True
16. The term "should" is use in NFPA 10 to state a requirement that must be
fulfilled.: False

1/6

, Extinguisher Exam
Study online at https://quizlet.com/_hu5v02

17. When a fire extinguisher is "Labeled", it refers to the six year and or hy-
dro-static label being applied to the extinguisher.: Factory test pressure
18. The service pressure of a fire extinguisher is the: Normal Operating Pressure
19. No special considerations are required in the selection and placement of
hydrogenated agent fire extinguishers: False
20. Dry Chemical fire extinguisher without a Class K rating used for the protec-
tion of Class K hazards must be replaced when they are due for a hydrostatic
retest or six year maintenance.: True
21. Which of the following Class B rated fire extinguishers should be considered
for the protection of a pressurized flammable liquid fire.: Dry Chemical fire extinguisher
22. All non-water based fire extinguishers are suitable for the protection of Class
B hazards.: False
23. All fire extinguishers, except Class D, may be used for the protection of class
A fires.: False
24. Cooking appliances that use a combustible cooking media (vegetable or
animal oils and fats) shall be protected with the following type of fire extin-
guisher.: Class K
25. NFPA 10 is the only NFPA document required to determine the installation
requirements for various hazards.: False
26. All class K fire extinguishers with an extended wand-type discharge device
must be remove from service.: False
27. The maximum rated fire extinguisher for an Extra Class A Hazard Occupancy
is 4A: False
28. If the area of an Ordinary Class A Hazard Occupancy is only 750 sq ft a 1-A
rated extinguisher may be provided.: False
29. An Ordinary Class A Hazard Occupancy is also designated as a ______________
Hazard Occupancy: Moderate
30. A commercial kitchen requires a class K fire extinguisher for fires involving
combustible cooking media plus additional extinguishers suitable for the build-
ing protection and specific hazard.: True
31. The minimum rated single extinguisher for a Class A Light Hazard Occupancy
is: 2-A
2/6

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
EmilyCharlene Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
451
Lid sinds
2 jaar
Aantal volgers
138
Documenten
21614
Laatst verkocht
1 dag geleden
Charlene\'s Scholastic Emporium.

Your Actual and Virtual Exam Tests Excellent Tutor.

3,7

98 beoordelingen

5
46
4
13
3
15
2
7
1
17

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen