100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

BACKFLOW PREVENTION ASSEMBLY TESTER PRACTICE EXAM ACTUAL EXAM ALL QUESTIONS AND CORRECT ANSWERS ALREADY GRADED A+

Beoordeling
-
Verkocht
-
Pagina's
30
Cijfer
A+
Geüpload op
29-08-2025
Geschreven in
2025/2026

BACKFLOW PREVENTION ASSEMBLY TESTER PRACTICE EXAM ACTUAL EXAM ALL QUESTIONS AND CORRECT ANSWERS ALREADY GRADED A+

Instelling
BACKFLOW PREVENTION ASSEMBLY TESTER
Vak
BACKFLOW PREVENTION ASSEMBLY TESTER










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
BACKFLOW PREVENTION ASSEMBLY TESTER
Vak
BACKFLOW PREVENTION ASSEMBLY TESTER

Documentinformatie

Geüpload op
29 augustus 2025
Aantal pagina's
30
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

1 || |P | a | g | e




BACKFLOW PREVENTION ASSEMBLY TESTER
PRACTICE EXAM ACTUAL EXAM ALL
QUESTIONS AND CORRECT ANSWERS ALREADY
GRADED A+

The relief valve of a Reduced Pressure Principle Assmbly remains closed during normal
| | | | | | | | | | | |


operation due to
| | |




(A) Supply side pressure | |



(B) The relief valve spring | | |




(C) Zone pressure |




(D) All the above - ANSWER: The relief valve spring
| | | | | | | |




What would cause a continual flow of water from of water the air inlet of a PVB prior
| | | | | | | | | | | | | | | | |


strting the field test
| | | |




(A) #2 shut off leaking by with baclpressure
| | | | | |




(B) Fouled ckeck valve | |




(C) #1 shull off leaking by
| | | |




(D) Fouled air inlet - ANSWER: Fouled air inlet | | | | | | |




A PVB can be installed in the following conditions
| | | | | | | |




(A) Backpressure
(B) Backsiphonage

,2 || |P | a | g | e


(C) B and D | |




(D) Pollutants and Contaminants - ANSWER: B Backsiphonage and D Pollutants | | | | | | | | |


and Contaminants
| |




When testing the check valve ob a SVB the water will not stop flowing What is the most
| | | | | | | | | | | | | | | | |


probabie cause
| |




(A) #2 shut off valve leaks by
| | | | |




(B) #1 shut off valve leaks by
| | | | |




(C) check valve is fouled | | |




(D) None of the above - ANSWER: #1 shut off valve leaks by
| | | | | | | | | | |




Which of the following could cause a closed system if installed in the sevice line
| | | | | | | | | | | | | |




(A) Hose bibb |




(B) Backflow Prevention Assembly | |




(C) venturi
(D) T & P valve - ANSWER: Backflow Prevention Assembly
| | | | | | | |




The critical level when testing the SVB is
| | | | | | |




(A) At the air inlet | | |




(B) At the #1 shutoff valve
| | | |




(C) At the vent screw
| | |




(D) there is on critical level - ANSWER: At the vent screw
| | | | | | | | | |

, 3 || |P | a | g | e


During the test of the check valve on a Pvb water continues to flow from the #2 test
| | | | | | | | | | | | | | | | |


cock What is the most probabie
| | | | | |




(A) Leaking #1 shut off valve | | | |




(B) Fouied air inlet | |




(C) Fouied ckeck valve | |




(D) Incorrect test procedure - ANSWER: Leaking #1 shut off valve | | | | | | | | |




Which of the following backflow assmblies are allowable for use against a
| | | | | | | | | | |


contaminant when the backflow could be caused by backpressure
| | | | | | | | |




(A) Atmospheric vacuum breaker | |




(B) Doubie check valve assembly | | |




(C) Pressure vacuum breaker assembly | | |




(D) Redued pressure backflow assembly - ANSWER: Redued pressure backflow
| | | | | | | |


assembly
|




While testing a backflow device under the influence of direct cross connection it is
| | | | | | | | | | | | |


observed that the hazard preset is a pollutant Which assembly is appropriate for
| | | | | | | | | | | | |


protection
|




(A) AVB , PVB , Air Gap | | | | |




(B) RP , DC , SVB | | | |




(C) Air Gap , RP , DC | | | | |




(D) Barometric Loop - ANSWER: Air Gap , RP , DC | | | | | | | | |




How many test cocks are required on a RP
| | | | | | | |

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Lectphilip West Virginia University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
160
Lid sinds
1 jaar
Aantal volgers
6
Documenten
17239
Laatst verkocht
20 uur geleden
WELCOME TO LECTPHILIP, A PLACE WHERE WE UNLOCK YOUR ACADEMIC OPPORTUNITIES

On this page, you find all documents, package deals and flashcards offered by seller lectphilip

4,3

21 beoordelingen

5
12
4
5
3
3
2
1
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen