100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

ICC CALIFORNIA UST SERVICE TECHNICIAN CERTIFICATION ACTUAL EXAM 200 QUESTIONS AND CORRECT DETAILED ANSWERS (100%VERIFIED ANSWERS) |AGRADE

Beoordeling
-
Verkocht
-
Pagina's
21
Cijfer
A+
Geüpload op
18-09-2024
Geschreven in
2024/2025

ICC CALIFORNIA UST SERVICE TECHNICIAN CERTIFICATION ACTUAL EXAM 200 QUESTIONS AND CORRECT DETAILED ANSWERS (100%VERIFIED ANSWERS) |AGRADE

Instelling
ICC CALIFORNIA UST SERVICE TECHNICIAN
Vak
ICC CALIFORNIA UST SERVICE TECHNICIAN










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
ICC CALIFORNIA UST SERVICE TECHNICIAN
Vak
ICC CALIFORNIA UST SERVICE TECHNICIAN

Documentinformatie

Geüpload op
18 september 2024
Aantal pagina's
21
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

ICC California UST Service Technician
Study online at https://quizlet.com/_b9nkfx

UDC was required at time of installation
January 1, 2000
for all systems installed after?
July 1, 2005, service techs shall possess
or work under someone who has a cur-
ICC UST Service Technician Exam
rent certification indicating he or she has
passed the?
ICC cert must be renewed every? 24 months
Service techs must possess or be em-
ployed by a person who has the appro- The individual has a tank testing license
priate contractor's license unless?
Tests UST monitoring equipment, trouble
Service tech is defined by any individual
shoots UST systems, and/or installs UST
who?
monitoring equipment.
If the manufacturer training no longer ex-
Approve comparable alternate training .
ist, the local agency may?
UST includes? Tank and connected piping
What is considered a UST? A petroleum storage tank.
What UST system meets the require-
Doubled wall tanks
ments for secondary containment?
According to title 23; the following piping
components if installed after July 1, 1987 Pressured product piping
must have secondary containment.
Considered "pipe" on tanks installed af- Pressured product piping and below
ter July 1, 2003. ground vapor recovery.
Under dispenser containment (UDC)
was required for all existing UST sys- December 31, 2003
tems by
System for exchanging gas vapors in a
storage tank and product in a fuel deliv- Stage 1 vapor recovery
ery truck
An approved method for non-visual mon-
Statistical Inventory Reconciliation (SIR)
itoring for existing UST systems.

0.2 gallons per hour


, ICC California UST Service Technician
Study online at https://quizlet.com/_b9nkfx
ATG must be capable for detecting a re-
lease of?
What is no longer an approved method
for non-visual monitoring on existing Manual inventory reconciliation.
UST systems?
Automatic line leak detectors installed on
underground piping with secondary con-
3 gallons per hour at 10 psi
tainment shall be capable of detecting a
leak of ?
How often should ATG be programmed
At least monthly
to test the tank?
According to PEI RP 300, a combustible Detect vapor leaks in a vapor recovery
gas can be used to? system.
According to PEI RP 300, a written
scope of work for vapor recovery instal- Construction plans
lation should include?
Positive shut off overfill protection device
must stop the flow of fuel when the tank 95% full
is no more then?
According to Executive Order (EO) VR
201-A , what could cause a nozzle shut Depended filter seal damage
off mechanism or malfunction?
According to VR 201-A, breakaway re-
Logged in GDF log
connection must be?
According to PEI RP 300 what is an IN-
Sketching a diagram on the inside cover
CORRECT method of documenting pip-
of vapor recovery equipment manual
ing location?
According to PEI RP 300 as built
drawing or pictures of the underground
maintained as long as UST is in service.
pipping and other components shall
be_________.
According to EO VR 101-E maintenance
Name and Designated UST Operator.
records are required to include what?




, ICC California UST Service Technician
Study online at https://quizlet.com/_b9nkfx
The Phil-Tite EVR Phase 1 system re-
quire that vapor vent pipes at any UST Used with no more than 3 p/v valves
system be
According to EO VR 2010 after installing
a new spout assembly in the Healy 900
Nozzle dispensing shut off test
nozzle the following test must be con-
ducted?
According to Healy EO VR 201-A a vapor Gasoline dispensing facility opera-
recovery record is to be maintained by? tor(GDF)
An enhanced leak detection test is re-
quired within how many feet of a public 1000 feet
drinking well?
What are the components of the Fire
Fuel, Heat/Ignition Source, Oxygen
Triangle?
If equipped with an over fill alarm, it must So it can be seen or heard from the de-
be located? livery location.
If installed, the following requires inde-
Automatic Tank Gauge, Liquid Product
pendent 3rd party certification to prove
Detectors, SIR
compliance with established regulations.
Where are ATG's installed? Opening in top of the tank
They're capable of alarming operator of
What is true about ATG's
low product level
Releases greater than 25 gallons that es-
cape secondary containment. Release
The following types of releases must be
that escape primary containment. Re-
reported to the local agency.
leases less than 25 gallons which es-
cape secondary containment
If an unauthorized product release
meets the requirements for reporting to
the local agency, verbal notification must 24 HRS, 5 DAYS
be made within ____hours, followed by a
written notification within ____days.
The following unusual conditions shall be
Water in spill buckets
reported to the local agency, EXCEPT:

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TheAlphanurse Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
5683
Lid sinds
2 jaar
Aantal volgers
177
Documenten
6763
Laatst verkocht
1 dag geleden
The Alpha Nurse

Certainly! The statement emphasizes NursingKnowledge Shop's commitment to providing high-quality, up-to-date resources to support the learning and professional development of individuals in the nursing field.

4,2

356 beoordelingen

5
213
4
80
3
26
2
10
1
27

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen