100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

PC, RC, and IC, EXAM QUESTIONS WITH COMPLETE SOLUTIONS (GRADED A+)

Beoordeling
-
Verkocht
-
Pagina's
3
Cijfer
A+
Geüpload op
29-02-2024
Geschreven in
2023/2024

PC, RC, and IC, EXAM QUESTIONS WITH COMPLETE SOLUTIONS (GRADED A+) There are several ways to identify that a ventilator circuit leak is present. They include all of the following EXCEPT: - Answer-the volume-time waveforms extend below the baseline A reliable formula for the calculation of static compliance is - Answer-Cs=Vt/{Pplat-EEP}) Causes of decreasing patient Cs include all of the following EXCEPT - Answer-air trapping In PV pressure must be increased when compliance decreases in order to maintain Vt delivery Reduced Cs can result in decreased PaO2 and increased PaCO2, therefore it is important to determine the cause and treat it. - Answer-True During volume ventilation decreasing PIP with a constant delivered Vt may signal im - Answer-True Treatment for increased Raw must be directed at the specific cause of the increased Raw of these include all of the following EXCEPT - Answer-inserting a chest tube

Meer zien Lees minder
Instelling
IC & RC
Vak
IC & RC








Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
IC & RC
Vak
IC & RC

Documentinformatie

Geüpload op
29 februari 2024
Aantal pagina's
3
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

PC, RC, and IC, EXAM QUESTIONS WITH
COMPLETE SOLUTIONS (GRADED A+)
The frequency of a patient-ventilator check depends on the policy of the institution and generally
occurs every 1 to 4 hours around the clock. - Answer-True

In addition to this regularly timed check, ventilator checks are also performed - Answer--prior to
obtaining ab ABG
-prior to obtaining hemodynamic data or bedside pulmonary function data
-when a ventilator change has been made

Newer microprocesser ventilators, such as the Puritan Bennett 840 and the VIASYS, do not
require the calculation of tubing compliance because they automatically compensate for this
factor - Answer-True

The highest pressure observed during inspiration, which is recorded on the flow sheet and Paw
may also be termed - Answer-PIP

EEP is the lowest pressure measured in the expiratory phase. The most sommon EEP is the set
PEEP or CPAP level. EEP does not include auto-PEEP. - Answer-False

There are several ways to identify that a ventilator circuit leak is present. They include all of the
following EXCEPT: - Answer-the volume-time waveforms extend below the baseline

A reliable formula for the calculation of static compliance is - Answer-Cs=Vt/{Pplat-EEP})

Causes of decreasing patient Cs include all of the following EXCEPT - Answer-air trapping

In PV pressure must be increased when compliance decreases in order to maintain Vt delivery
Reduced Cs can result in decreased PaO2 and increased PaCO2, therefore it is important to
determine the cause and treat it. - Answer-True

During volume ventilation decreasing PIP with a constant delivered Vt may signal im - Answer-
True

Treatment for increased Raw must be directed at the specific cause of the increased Raw of these
include all of the following EXCEPT - Answer-inserting a chest tube

The Cs pressure-volume curve provides alveolar opening data for ventilating a patient with
decreasing compliance such as ARDS, it is appropriate to try and ventilate the patient - Answer-
somewhere between the lower and upper inflection points

Setting PEEP below the lower inflection point of the pressure-volume curve helps to inflated
alveoli from collapsing and re-expanding with each breath. - Answer-False
€19,00
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
biggdreamer Havard School
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
246
Lid sinds
2 jaar
Aantal volgers
68
Documenten
17943
Laatst verkocht
4 dagen geleden

4,0

38 beoordelingen

5
22
4
4
3
6
2
2
1
4

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen