100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

FDNY S15 Supervision Of Foam-Water Sprinkler Systems (Citywide) Practice Exam Questions And Correct Answers

Beoordeling
-
Verkocht
-
Pagina's
36
Cijfer
A+
Geüpload op
07-01-2026
Geschreven in
2025/2026

FDNY S15 Supervision Of Foam-Water Sprinkler Systems (Citywide) Practice Exam Questions And Correct Answers

Instelling
FDNY S15
Vak
FDNY S15











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
FDNY S15
Vak
FDNY S15

Documentinformatie

Geüpload op
7 januari 2026
Aantal pagina's
36
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

FDNY S15 Supervision Of Foam-
Water Sprinkler Systems
(Citywide) Practice Exam
Questions And Correct
Answers


Sprinkler System - ANS -A fire extinguishing system, other than a water mist system, that utilizes water
as the extinguishing agent.



Automatic/Non-Automatic Sprinkler Systems - ANS -Shall be inspected by a competent person holding a
S12 CoF and employed or contracted by the owner, to see that all parts of the system are in good
working order, and that the fire department connections, if any, are ready for immediate use by the fire
department.



6 Extra Sprinkler Heads - ANS -A Supply of ____ shall be kept available on the premises, to replace
promptly any fused or damaged_____



Fire Department Connections/Connections for a Sprinkler System - ANS -Subjected to a hydrostatic
pressure test to demonstrate its suitability for fire department use, every 5 years.



Impairment Coordinator - ANS -Complies with the requirements of study material



Impairment Coordinator - ANS -Shall take the actions when a standpipe system, sprinkler system or the
fire alarm system is out of service.



Impairment Coordinator - ANS -Shall maintain records of all system inspections, tests, servicing and
other items of maintenance.

,Impairment Coordinator - ANS -Building Owner in the absence of a specific designee.



Planned Removal From Service - ANS -When the system, or a portion of the sprinkler system, is placed
out of service for a scheduled inspection, testing, regular maintenance, minor repairs or for construction
affecting not more than 1 floor.



Unplanned Out of Service Condition - ANS -A serious defect in the sprinkler system including, but not
limited to: an empty tank, a break or major leak in the system's water piping, inoperative or shut water
supply valves, defective fire department connections, construction related shut downs affecting more
than one floor, or complete or partial shut downs of the sprinkler system, other than a shut down for a
planned removal form service.



Tag Requirement - ANS -Shall be used to indicate that a system, or portions are out of service.



Tags - ANS -Shall indicate the are affected, a brief description of the condition, the occupancy
classification, CoF number and the estimated time until the system becomes operational.



Green Tags - ANS -If no impairment is found in the entire system ___ will be placed on the main control
valve.



Systems Fully Out of Service - ANS -White Discs 8-9" in diameter is placed on all affected fire department
connections. A red tag shall be placed at the main control valve indicating the sprinkler company name,
date of removal from service and anticipated return to service date.



Systems Partially Out of Service - ANS -Blue Discs 8-9" in diameter is placed on all affected fire
department connections. a red tag shall be placed at the main control valve and ay closed sectional
valve indicating the company name, date or removal from service and anticipated return to service date.



Fire Watch - ANS -Building staff trained and knowledgeable in conducting a fire watch may conduct a
____ in lieu of a fire guard during the initial 4 hours of a planned removal from service, or after discovery
of an unplanned out-of-service condition, provided that the floor or area in which the fire protection
system is out of service does not exceed 50,000 sqft.

,CoF Holder - ANS -Responsibilities include: Record Keeping, Records, Detailed Records, Riser Card
Updates.



Record Keeping - ANS -Maintain a detailed record of all inspections.



Records - ANS -All system inspections, tests, servicing and other maintenance required by this NYC Fire
Code, the NYC Fire rules or the referenced standards shall be maintained on the premises for a
minimum of 3 years.



Detailed Records - ANS -Shall include information relative to conditions of water supply, gravity and
pressure tanks and levels therein, valves, risers, piping, sprinkler heads and fire department
connections, alarms, fire, booster and special service pumps, obstructions, and conditions of all other
system equipment and appurtenances. All defects and/or impairments shall be noted on the report.



Riser Card - ANS -An approved card bearing the dates of each inspection, CoF number and signature of
the CoF holder shall be posted on the premises near therein water supply control valve.



S12/S15 CoF Holder - ANS -Responsibilities include Visual inspections only, proper notification and
record inspection results for examinations by FDNY.



Alarm Notification Appliance - ANS -A fire alarm system component, such as a bell, horn, speaker, light,
text display or vibration device that issues an audible, tactile, and/or visual alert.



Alarm Signal - ANS -A notification indicating an emergency requiring immediate action such as a
notification indicative of fire.



Antifreeze Sprinkler System - ANS -A wet pipe sprinkler system employing automatic sprinklers that are
attached to a piping system that contains an an antifreeze solution and is connected to a water supply.
The antifreeze solution is discharged, followed by water immediately upon operation of sprinklers
opened by heat from a fire



Automatic Ball Drip - ANS -An automatic drain valve horizontally installed at the low point in the piping
between the lower check valve and the fire department connection of automatic sprinkler systems.

, Water pressure from a Fire Department pumper automatically closes this valve. It automatically re-
opens when pressure ceases, permitting this piping to drain and thereby prevent freezing.



Central Station - ANS -A facility that receives alarm signals from a protected premises and retransmits or
otherwise reports such alarm signals to the department.



Combination Standpipe and Sprinkler System - ANS -A system where the water piping services both 2.5"
outlets for Fire Department use and outlets for automatic sprinklers.



Concealed Sprinkler - ANS -A recessed sprinkler with a cover plate.



CMSA - ANS -Control Mode Specific Application Sprinklers



Control Mode Specific Application (CMSA) Sprinklers - ANS -Designed to control a fire until its original
fuel source is depleted or until fire-fighting activities can commence. A fire is controlled by cooling the
ceiling-level air temperatures, reducing the fire's rate of heat release and pre-wetting adjacent
combustibles.



Control Valve - ANS -A valve controlling flow to water-based fire protection systems. They do NOT
include hose valves, inspector's test valves, drain valves, trim valves for dry pipe, preaction and deluge
valves, check valves or relief valves.



Control Valves - ANS -Include OS&Y, Curb valves



OS&Y Valve - ANS -Outside Stem & Yoke Valve



OS&Y (Outside Stem & Yoke) - ANS -An indicating type of control valve used for fire sprinkler system.



Curb Valve - ANS -Non-indicating gate valve equipped with a cast iron extension box flushed with a
sidewalk with an operation nut of 1.25", this valve is operated using a special curb key wrench. This
valve controls the municipal water supply serving the fire sprinkler system.
€10,88
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten

Maak kennis met de verkoper
Seller avatar
Lectcaptain

Maak kennis met de verkoper

Seller avatar
Lectcaptain Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2
Lid sinds
8 maanden
Aantal volgers
0
Documenten
594
Laatst verkocht
5 dagen geleden
TOPNOTCH EXAM GUIDES

In need of study guides and wondering where and when to get them? Worry no more because I\'ve got you. Access actual tests 100% verified. ATI, NURSING, PMHNP, TNCC, USMLE, ACLS, WGU AND ALL EXAMS guaranteed success. Here, you will find everything you need in NURSING EXAMS AND TESTBANKS. Contact us, to fetch it for you in minutes if we do not have it in this shop. BUY WITHOUT DOUBT!!!!Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied.

Lees meer Lees minder
0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen