100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

ARDMS ADULT ECHO 2026 REVISION EXAM QUESTIONS AND ANSWERS RATED A+

Beoordeling
-
Verkocht
-
Pagina's
18
Cijfer
A+
Geüpload op
06-01-2026
Geschreven in
2025/2026

ARDMS ADULT ECHO 2026 REVISION EXAM QUESTIONS AND ANSWERS RATED A+

Instelling
Ardms
Vak
Ardms










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Ardms
Vak
Ardms

Documentinformatie

Geüpload op
6 januari 2026
Aantal pagina's
18
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

ARDMS ADULT ECHO 2026 REVISION EXAM QUESTIONS
AND ANSWERS RATED A+
✔✔The normal wall thichness measurement should be what - ✔✔<11 mm or <1.1 cm

✔✔Simpsons rule is used for measuring what - ✔✔EF

✔✔What is the most accurate measurement for assessing LVF - ✔✔Simpsons

✔✔The formula for the quantification of pulmonary blood volume vs systemic volume -
✔✔Qp/Qs

✔✔with Qp/Qs L-R shunts with volume overload to right heart. When the right heart or
Qp volume is greater than ____ of the left heart or the Qs volume, the shunt is
significant - ✔✔1.5

✔✔on M mode the aorta is measured at - ✔✔end systole

✔✔External focusing of the transducer is with the _ - ✔✔lens

✔✔intermal focusing of the transducer is with the - ✔✔curved element and phased
array focusing is with the electronics of the US system

✔✔Aliasing occurs when the velocity reaches more than____ of the PRF - ✔✔1/2

✔✔Contrast can be used to _____ the Doppler signal in order to obtain an adequate
display - ✔✔highlight

✔✔When using a contrast media the sonographer must _____ acoustic power -
✔✔decrease. Higher power will burst the bubbles of contrast

✔✔Type of artifact caused by the regular periodic spacing of elements within the array.
They create artifacts by measuring time of flight to an object located outside the main
beam and placing the detected echo as if the interface were located along the US path
of the main beam - ✔✔Grating lobes

✔✔Grating lobes are found in ______ transducers - ✔✔array

✔✔An associated finding of interatrial septal aneurysm is an - ✔✔ASD. An interatrial
septal aneurysm is bulging of the fossa ovalis region of the interatrial septum. Septal
aneurysms have a high likelihood of fenestration ( up to 90%)

,✔✔A way of describing the extent to which a signal can vary yet still be accurately
processed. Measured in decibels (dB). - ✔✔Dynamic range

✔✔Dilation of the CS can indicate an increase in _____ __________ pressure, and
_______ - ✔✔RA, Persistent Left Superior Vena Cava

✔✔T/F PISA can be used to calculate regurg when there are multiple regurg jets -
✔✔False, it is difficult to obtain a flow convergence when theree are multiple jets

✔✔The modality that obtains myocardial velocities and derives the information from the
valve annulus - ✔✔TDI

✔✔T/F Doppler shift is directly related to tranducer frequency - ✔✔true

✔✔Doppler shift is directly proportional to _________ - ✔✔velocity

✔✔The optimal Doppler angle for echo is __ -______ degrees - ✔✔0- 20 degrees

✔✔The sample depth and PRF are ______ proportional - ✔✔Inversely

✔✔The _______ generates sound pulses that excites the transducers poezoelectiric
crystals and create sound beams - ✔✔pulser

✔✔The ______ determines amplitude, PRP, PRF - ✔✔pulser

✔✔T/F the sonographer can adjust the electrical voltage spike of the pulser - ✔✔True

✔✔A narrow dynamic range means _______ gray shaded, and ______ contrast -
✔✔fewer, high

✔✔This artifact is created when sound reflects off a strong reflector and is redirected
toward a second structure - ✔✔mirror image, the redirection causes a replica, second
copy

✔✔This artifact is the result of width and length mode vibrations, immediate
reverberations at crystal-tissue interface and interference phenomena. - ✔✔Side lobes

✔✔Side lobes are produced by ________ crystal transducers - ✔✔single

✔✔A technique called ______ lower side lobes intensity for electronic arrays -
✔✔apodization

, ✔✔T/F moving the color box region of interest can change the frame rate - ✔✔True, if
the ROI is lower in the section it will decrease the frame rate.

✔✔T?F changing the PRF will change the frame rate - ✔✔True increase PRF increase
FR. Decreasing image depth.

✔✔dP/dt assesses the LV ___- performance - ✔✔systolic

✔✔Color Doppler can display ____ frequency shifts, the _____ of BF, and the _______
of flow - ✔✔mean, direction, quality ( such as laminar or turbulent)

✔✔Spatial __ temporal _______ will give the hishest intensity - ✔✔Spatial peak,
temporal peak (SPTP)
spatial average, temporal average sill give the lowest intnsity

✔✔The initial treatment for ventricular fib is _______ _________ - ✔✔unsynchronized
cardioversion. Joules or electricity are delivered when the paddles are pressed. A
standard 200 joules is required using biphasic defibrillators.

✔✔The period of time when all valves are closed; the ventricles are CONTRACTING
and the ventricular pressure in INCREASING - ✔✔isovolmetric contration

✔✔The slow filling phase of diastole is called what - ✔✔diastasis

✔✔How long is a normal PR interval - ✔✔0.16- 0.11 sec

✔✔Normal QRS interval is how long - ✔✔.06-0.11

✔✔Atrial depolarization on an EKG occurs during the ________ wave - ✔✔T wave

✔✔small fibrous nodules located at the center of each cusp are called - ✔✔nodules
Arantius

✔✔T/F heart valves open passively - ✔✔true---This is due to pressure opening the
valves

✔✔The order of ventricular filling - ✔✔1. Rapid filling (ventricular systole)
2. Slow filling (diastasis)
3. artrial systole

✔✔How many veins dump deoxygenated blood into the RA in a normal heart - ✔✔3 ---
IVC, SVC, CS

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
BOARDWALK Havard School
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
182
Lid sinds
1 jaar
Aantal volgers
6
Documenten
24136
Laatst verkocht
2 dagen geleden
BOARDWALK ACADEMY

Ace Your Exams With Top Quality study Notes And Paper✅✅ ALL ACADEMIC MATERIALS AVAILABLE WITH US✅✅ LEAVE A REVIEW SO THAT WE CAN LOOK AND IMPROVE OUR MATERIALS.✅✅ WE ARE ALWAYS ONLINE AND AVAILABLE DONT HESITATE TO CONTACT US FOR SYUDY GUIDES!!✅✅ EVERYTHING IS GRADED A+✅✅ COLOUR YOUR GRADES WITH US , WE ARE HERE TO HELP YOU DONT BE RELACTANT TO REACH US

3,7

33 beoordelingen

5
14
4
6
3
7
2
0
1
6

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen