100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

PRESTRESSED CONCRETE DESIGN EXAM 2025 | ALL QUESTIONS AND CORRECT ANSWERS | ALREADY GRADED A+ | VERIFIED ANSWERS | LATEST EXAM

Beoordeling
-
Verkocht
-
Pagina's
25
Cijfer
A+
Geüpload op
22-03-2025
Geschreven in
2024/2025

PRESTRESSED CONCRETE DESIGN EXAM 2025 | ALL QUESTIONS AND CORRECT ANSWERS | ALREADY GRADED A+ | VERIFIED ANSWERS | LATEST EXAM

Instelling
PRESTRESSED CONCRETE DESIGN
Vak
PRESTRESSED CONCRETE DESIGN










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
PRESTRESSED CONCRETE DESIGN
Vak
PRESTRESSED CONCRETE DESIGN

Documentinformatie

Geüpload op
22 maart 2025
Aantal pagina's
25
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

PRESTRESSED CONCRETE DESIGN EXAM 2025 | ALL
QUESTIONS AND CORRECT ANSWERS | ALREADY
GRADED A+ | VERIFIED ANSWERS | LATEST EXAM

A contractor pursuing approval for submittal items prior to construction ------
---CORRECT ANSWER-----------------shop drawings and design drawings
showing detailed engineering and installation



The transition between the corrosion protection for the bond and free
stressing lengths shall be designed to ensure ---------CORRECT ANSWER-
----------------continuous protection from corrosive attack



The following responsibilities must be assigned before started a rock and
soil anchor project,with the exception of ---------CORRECT ANSWER---------
--------a final punchlist for initiating the warranty of the system



If grout is used to protect the outside of a steel trumpet, a minimum cover
of __ is required ---------CORRECT ANSWER-----------------2 inches



The use of UV- resistant coating bearing plates is ---------CORRECT
ANSWER-----------------permitted as an alternate to a galvanized plate



A coupler used in an anchorage system must be sealed to either the
encapsulation or the tendon sheath using ---------CORRECT ANSWER------
-----------a heat shrink sleeve

,The connection between the trumpet and the bearing plate must ---------
CORRECT ANSWER-----------------be watertight



The prestressing steel in the free length area is protected by ---------
CORRECT ANSWER-----------------a corrosion- inhabiting comound,grout
encasement,and the trumpet



When encapsulation in not available under class I conditions, the contractor
or installer ---------CORRECT ANSWER-----------------is permitted to use an
epoxy- coated strand that has passed the appropriate water pressure test



Type II Portland cement shall be used for grouting anchor system provided
that ---------CORRECT ANSWER-----------------the sulfate content is
between 0.1 and 0.2 percent



Grout socks must conform to ---------CORRECT ANSWER-----------------
ASTM D 4751



Plastic tubing wall thickness is acceptable for use in anchorage systems
when ---------CORRECT ANSWER-----------------its normal thickness for
PVC os .040 inches



The test method for the melting point of wax ---------CORRECT ANSWER---
--------------is ASTM D-566

, A trumpet should have a minimal wall thickness of ---------CORRECT
ANSWER-----------------.125 inches



A permanently free stressing length in a soil anchor can be protected by all
of the following except ---------CORRECT ANSWER-----------------epoxy



The minimum free stressing length for a prestressing steel bar is ---------
CORRECT ANSWER-----------------10 feet



Centralizers in an anchorage system should be spaced ---------CORRECT
ANSWER-----------------at 10 feet on center or less



The corrosion protection surrounding the unbonded length of the tendon ---
------CORRECT ANSWER-----------------shall not contact the bearing plate or
the anchorhead



___ are approved for repair on damaged corrugated sheath ---------
CORRECT ANSWER-----------------a heat shrink sleevs or heat shrink tape



Drill bits used to drill a hole for an anchor ---------CORRECT ANSWER-------
----------must not be more than 1/8th-inch smaller than the diameter of the
drill hole



The temperature of grout at the time of the placement must ---------
CORRECT ANSWER-----------------not exceed 90A when ambient
temperatures rise above 100A and be balanced with the use of a suitable

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
StudyWay Capella University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
106
Lid sinds
2 jaar
Aantal volgers
43
Documenten
1828
Laatst verkocht
3 dagen geleden
INVEST AND UNLEASH THE POWER OF KNOWLEDGE NOW!

THIS PREMIUM STUVIA ACCOUNT GIVES YOU ACCESS TO EXCLUSIVE EXAMS, FLASH CARDS, TEST BANKS, AND STUDY GUIDES TAILORED FOR YOUR SUCCESS. ELEVATE YOUR GRADES, ACCELERATE YOUR LEARNING, AND SUPERCHARGE YOUR STUDIES: DIVE INTO A WORLD OF ACADEMIC EXCELLENCE!

4,5

59 beoordelingen

5
46
4
5
3
3
2
2
1
3

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen