100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

SONOGRAPHY PRINCIPLES AND INSTRUMENTS TEST BANK EXAM QUESTIONS AND CORRECT ANSWERS|ACCURATE REAL EXAM WITH RATIONALE| ALREADY GRADED A|GUARANTEED PASS|LATEST UPDATE 2024|2025

Beoordeling
-
Verkocht
-
Pagina's
67
Cijfer
A+
Geüpload op
04-09-2024
Geschreven in
2024/2025

SONOGRAPHY PRINCIPLES AND INSTRUMENTS TEST BANK EXAM QUESTIONS AND CORRECT ANSWERS|ACCURATE REAL EXAM WITH RATIONALE| ALREADY GRADED A|GUARANTEED PASS|LATEST UPDATE 2024|2025

Instelling
SONOGRAPHY PRINCIPLES AND INSTRUMENTS
Vak
SONOGRAPHY PRINCIPLES AND INSTRUMENTS











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
SONOGRAPHY PRINCIPLES AND INSTRUMENTS
Vak
SONOGRAPHY PRINCIPLES AND INSTRUMENTS

Documentinformatie

Geüpload op
4 september 2024
Aantal pagina's
67
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

SONOGRAPHY PRINCIPLES AND INSTRUMENTS TEST BANK
EXAM QUESTIONS AND CORRECT ANSWERS|ACCURATE
REAL EXAM WITH RATIONALE| ALREADY GRADED
A|GUARANTEED PASS|LATEST UPDATE 2024|2025

curved linear phased array - CORRECT ANSWER AKA
curvilinear array or convex array
contains a large number of linearly arranged piezoelectric elements (120-250)
sequentially pulsed transducer elements
produced blunted/ curved sector image with a larger near field footprint
uses electronic focusing & steering


sector phased array - CORRECT ANSWER small footprint with a large number of linearly
arranged rectangular piezoelectric elements
triangle shape created by electronic steering

vector array - CORRECT ANSWER combine sequenced linear array and phased array
techniques to provide a trapezoidal image. larger footprint than phased array

Harmonic imaging - CORRECT ANSWER a low frequency beam is transmitted into the patient
but the system displays the received information as double the frequency
5mhz transmitted = 10 MHz displayed

what does harmonic imaging allow - CORRECT ANSWER deeper penetration with lower
transmitted frequency and improved lateral resolution with increased received frequency

harmonic imaging has what sized beam width? - CORRECT ANSWER provides a narrow beam
width to reduce side lobe/grating lobe artifact

what is axial resolution and what does it improve with? - CORRECT ANSWER ability to
resolve two separate structures that lie parallel to the ultrasound beam

improves with higher transducer frequency, wider bandwidths and shorter pulse lengths

lateral resolution and what does it improve with - CORRECT ANSWER ability to resolve two
separate structures that lie perpendicular to one another

improves with higher frequency, beam focusing, wider bandwidths and more superficial
structures

contrast resolution - CORRECT ANSWER ability to differentiate two structures with varied
echogenicity

compression will change the contrast resolution of the image

,increasing compression and the dynamic range will - CORRECT ANSWER allow more shades
of gray - increased contrast resolution

educational resolution - CORRECT ANSWER AKA slice thickness resolution
improves with thinner image slices
most difficult to adjust

what improves elevational resolution - CORRECT ANSWER increased transducer frequency &
focusing

temporal resolution - CORRECT ANSWER the ability to detect that an object has moved over
time
a decreased temporal resolution causes the image to lag


how to improve temporal resolution - CORRECT ANSWER decreased focal zones
smaller field of view
decreased imaging depth
decreased line density

external/mechanical focusing - CORRECT ANSWER lens placed inside the transducer in front
of the element to focus the beam before it exits the transducer

internal or electronic focusing - CORRECT ANSWER varied timing of the pulser voltage used
to vary the firing of elements in an array
used to steer the beam, helps to visualize needles during procedures

Hard copy storage - CORRECT ANSWER any kind of film
thermal paper
Kodak glossy printers
inkjet printers
videotapes
disadvantage - images degrade over time due to damage

hardware, software, digital medias - CORRECT ANSWER DICOM- digital imaging and
communication in medicine, standard image format for the medical community

PACS - CORRECT ANSWER Picture Archiving and Communication System
the best form of storage for DICOM images
reflection - CORRECT ANSWER return of the ultrasound wave to the transducer from a
smooth surface

when does the greatest amount of reflection occur - CORRECT ANSWER when the incident
beam is perpendicular to structure (specular reflection)

,scatter - CORRECT ANSWER deflection of ultrasound waves from small structures (red blood
cells scatter sound)

refraction - CORRECT ANSWER deflection of Ultrasound waves due to media with varied
acoustic impedance

attenuation - CORRECT ANSWER loss of Ultrasound signal due to absorption in tissues as it
travels

higher frequencies have higher attenuation rates

what generates the voltage that excites the piezoelectric elements so it produces a sound pulse -
CORRECT ANSWER pulser

The pulser determines the ___ of the voltage spike applied to the element - CORRECT
ANSWER amplitude

____ determines the PRF of the transducer - CORRECT ANSWER Pulser

T or F the pulser can be adjusted by the sonographer using the power output - CORRECT
ANSWER true

___ uses mechanical focusing & steering with only one element - CORRECT ANSWER single
element

multiple elements used to create an image by varying timing of the electrical pulses (firing) to
different elements in the array - CORRECT ANSWER phased array

phased array uses - CORRECT ANSWER electronic steering & focusing

transducer frequency is ___ proportional to penetration and directly proportional to resolution -
CORRECT ANSWER inversely

name three things that are inversely proportional to transmitted frequency - CORRECT
ANSWER beam width, spatial pulse length and pulse duration

Annular array - CORRECT ANSWER 5 concentric ring shaped piezoelectric elements that
produces a cylindrical beam (sector shaped image)
requires mechanical steering

with an annular phased array outer elements image ___. Central elements image ____. -
CORRECT ANSWER outer - image deeper structures
inner elements- superficial structures

sequential linear array - CORRECT ANSWER AKA switch array
200 rectangle elements across face of transducer

, parallel acoustic lines are transmitted sequentially
uses mechanical focusing (curved lense or crystal)*

what transducer has the same field of view in near and far fields ( no trapezoid FOV) -
CORRECT ANSWER switched array (sequential linear array)


linear phased array - CORRECT ANSWER contains 200 elements
elements fired at varied times to allow for electronic focusing & beam steering
phasing creates trapezoidal FOV

curved sequential array - CORRECT ANSWER similar construction & function as a sequential
linear array
no beam steering
blunted sector FOV
Requires mechanical focusing


NAS - CORRECT ANSWER network attached storage - computer memory device that are apart
from the PACS system. used to store the original study and the backup files in separate locations
= hardware

RIS or HIS - CORRECT ANSWER Radiology Information System
Hospital Information System
a software program that stores medical records, appointments and other patient information

2D imaging - CORRECT ANSWER grayscale imaging
used to assess chamber size, structure motion valvular structure & motion

in 2D imaging the amplitude of the reflection is directly proportional to - CORRECT ANSWER
the brightness of the pixel on the display

image depth is inversely proportional to - CORRECT ANSWER pulse repetition frequency

what can be used to calculate the time of flight or go return time? - CORRECT ANSWER range
equation

what is the range equation used for? - CORRECT ANSWER used to calculate depth of a
structure for pixel placement on the screen

what is the range equation - CORRECT ANSWER distance to reflector = 1/2 speed of sound x
time of flight

power output - CORRECT ANSWER adjusts the electrical voltage applied to the PE elements
in the transducer; changes the energy of the beam; used as a last resort to increase penetration
and reflected sound wave amplitude
€18,12
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten

Maak kennis met de verkoper
Seller avatar
muriithipatrick66

Maak kennis met de verkoper

Seller avatar
muriithipatrick66 Chamberlain College Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
0
Lid sinds
1 jaar
Aantal volgers
0
Documenten
31
Laatst verkocht
-

0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen