Massachusetts Plumbing Comprehensive Frequently Tested Exam Questions With Verified Multiple Choice and Conceptual Actual 100% Correct Detailed Answers Guaranteed Pass!!Current Update!! 1. GIVEN: A journeyman plumber and an apprentice, (who are employed by a master plumber), are installing the sanitary DWV and water distribution system in a five-story residential condominium complex. QUESTION: What answer below shall be considered most correct to complete the following "Plumbing code knowledge" related statement: CPVC-(Chlorinated Polyvinyl Chloride) pipe and fittings may be used provided that none of this material is located within ____-inches of any connection to a hot water tank as defined in MGL. c. 142, § 17 A) 12 B) 18 C) 20 D) 24 E) 30 - ANSWER 24 inches 2. A journeyman plumber and apprentice are roughing-in multiple fixtures in a new fitness center. The facility will include a juice bar, temporary daycare room, men's and women's toilet facilities and men's and women's locker rooms. QUESTION: What answer below shall be considered most correct to complete the following "Plumbing code knowledge" related statement: A ________-vent is a branch vent that serves two or more floor-outlet fixtures that are battery wasted. The vent extends from the top of the horizontal soil and/or waste branch in front of the last fixture waste and connects to a vent stack or stack vent that is adjacent to the down-stream end of the horizontal branch. A) Side B) Loop C) Relief D) Circuit - ANSWER 3. MATCH: Elevated pressure Flow designation Ten P.S.I.G. or less Less than 2-P.S.I A) 3 P.S.I.G. or ten times B) Inlet pressure C) E.H.D. loop D) Prof. Engineer - ANSWER flow designation-c Ten P.S.I.G. or less-a Less than 2-P.S.I-b elevated pressure- d 4. A journeyman plumber is installing category-I gas appliances and equipment in the basement of a building. A 120,000 BTU/hr. boiler and 40,000 BTU/hr. water heater are being installed. QUESTION: What answer below shall be considered most correct to complete the following "Gas code knowledge" related statement: The boiler requires a minimum of _____-cu. ft. of air to support proper combustion A) 2,400 cu. ft. B) 120 sq. in. C) 3,200 sq. ft. D) 800 cu. ft. - ANSWER 2,400 cu. ft. 120,000/50 5. What answer below shall be considered most correct to complete the following "Gas code knowledge" related statement: The code would require the gas vent penetrating the roof in-[FIGURE-TP-B-Q1-1A: GAS VENT SIZING] as identified at point-[A] to be not less than ______ above any portion of a building within 10-feet horizontally. A) 24" B) 3-feet C) 30-inches D) Forty-two-inches - ANSWER 24

Montrer plus Lire moins
Établissement
MASSACHUSETTS PLUMBERS JOURNEYMAN
Cours
MASSACHUSETTS PLUMBERS JOURNEYMAN











Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
MASSACHUSETTS PLUMBERS JOURNEYMAN
Cours
MASSACHUSETTS PLUMBERS JOURNEYMAN

Infos sur le Document

Publié le
16 décembre 2025
Nombre de pages
48
Écrit en
2025/2026
Type
Examen
Contient
Questions et réponses

Sujets

Aperçu du contenu

Massachusetts Plumbing 2026-2027
Comprehensive Frequently Tested Exam Questions
With Verified Multiple Choice and Conceptual
Actual 100% Correct Detailed Answers

Guaranteed Pass!!Current Update!!


1. GIVEN: A journeyman plumber and an apprentice, (who are employed by a
master plumber), are installing the sanitary DWV and water distribution
system in a five-story residential condominium complex. QUESTION: What
answer below shall be considered most correct to complete the following
"Plumbing code knowledge" related statement: CPVC-(Chlorinated Polyvinyl
Chloride) pipe and fittings may be used provided that none of this material is
located within ____-inches of any connection to a hot water tank as defined in
MGL. c. 142, § 17
A) 12
B) 18
C) 20
D) 24

E) 30 - ANSWER 24 inches


2. A journeyman plumber and apprentice are roughing-in multiple fixtures in a
new fitness center. The facility will include a juice bar, temporary daycare
room, men's and women's toilet facilities and men's and women's locker
rooms. QUESTION: What answer below shall be considered most correct to
complete the following "Plumbing code knowledge" related statement: A
________-vent is a branch vent that serves two or more floor-outlet fixtures
that are battery wasted. The vent extends from the top of the horizontal soil

, and/or waste branch in front of the last fixture waste and connects to a vent
stack or stack vent that is adjacent to the down-stream end of the horizontal
branch.
A) Side
B) Loop
C) Relief

D) Circuit - ANSWER loop


3. MATCH:
Elevated pressure
Flow designation
Ten P.S.I.G. or less
Less than 2-P.S.I
A) 3 P.S.I.G. or ten times
B) Inlet pressure
C) E.H.D.

D) Prof. Engineer - ANSWER elevated pressure- d
flow designation-c
Ten P.S.I.G. or less-a
Less than 2-P.S.I-b


4. A journeyman plumber is installing category-I gas appliances and equipment in
the basement of a building. A 120,000 BTU/hr. boiler and 40,000 BTU/hr.
water heater are being installed. QUESTION: What answer below shall be

, considered most correct to complete the following "Gas code knowledge"
related statement: The boiler requires a minimum of _____-cu. ft. of air to
support proper combustion
A) 2,400 cu. ft.
B) 120 sq. in.
C) 3,200 sq. ft.

D) 800 cu. ft. - ANSWER 2,400 cu. ft. 120,000/50


5. What answer below shall be considered most correct to complete the
following "Gas code knowledge" related statement: The code would require
the gas vent penetrating the roof in-[FIGURE-TP-B-Q1-1A: GAS VENT SIZING] as
identified at point-[A] to be not less than ______ above any portion of a
building within 10-feet horizontally.
A) 24"
B) 3-feet
C) 30-inches

D) Forty-two-inches - ANSWER 24


6. In Massachusetts copper tubing and fittings may be used for natural gas
piping
A) Provided that the tubing is type-k with flared fitting connections.
B) When approved by the authority having jurisdiction.
C) At interior locations only and not concealed.
D) If the gas contains no more than .03 grains of hydrogen sulfide per 100 cu. ft. of
gas.

, - ANSWER D If the gas contains no more than .03 grains of hydrogen sulfide per
100 cu. ft. of gas


7. A journeyman plumber and apprentice, who are employed by a master
plumber, are installing a natural gas fired category-1 boiler and water heater to
an interior, clay tile lined, masonry chimney. When measured in compliance
with the code the chimney "height" is 48-feet. QUESTION: What answer below
shall be considered most correct to complete the following "Gas code
knowledge" related statement: _____ is the maximum allowable amount of 6-
inch single wall metal vent connector material that may be installed
horizontally to connect the boiler and water heater to the chimney
A) 36-feet
B) 50% of the chimney height
C) 48-feet

D) 9-feet - ANSWER 36 feet


8. A journeyman plumber is installing a natural gas fired category-1 boiler with
an indirect water heater. Type-B double wall vent connector material is being
used to vent products of combustion from the boiler to an interior tile lined
masonry chimney that is 35-feet in height. QUESTION: What answer below
shall be considered most correct to complete the following "Gas code
knowledge" related statement: A clearance of _____ from combustibles shall
be maintained when using/installing type-B vent materials.
A) 6-inches
B) 2"
C) 1-foot

D) One-inch - ANSWER one inch
€13,57
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
EWLindy Chamberlain College Of Nursing
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
705
Membre depuis
3 année
Nombre de followers
431
Documents
7336
Dernière vente
2 jours de cela
EN.CY.CLO.PE.DI.A

Hello, I am Passionate about education with over 7yrs teaching.. Welcome to my page...my documents are 100% guaranteed to help you Ace in your career path, Combining a wide view of career courses education Journey Proffesionaly. Will be very helpful for those students who want to make a change in nursing field and other close courses . Please go through the sets description appropriately before any purchase. The *Sets have been used years in years out by serious students to exercise, revise and even pass through their examinations. All revisions done by Expert Minds. This Gives You No Excuse To Leave A Bad Review. Thankyou . SUCCESS IN YOUR EDUCATION JOURNEY !! GOODLUCK IN YOUR STUDIES.

Lire la suite Lire moins
3,8

106 revues

5
54
4
13
3
16
2
6
1
17

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions