ANSWERS GRADED A+ LATEST UPDATE.
The OSHA Lead Construction Standard, 8 CCR 1532.1, applies to: ANS >>>
Correct Answer: Construction activities that disturb paint with any
detectable level of lead.
What are the minimum and maximum employee air monitoring flow
rates according to NIOSH Method 7082? ANS >>> Correct Answer: 1.0 to
4.0 LPM
Cal/OSHA's Respiratory Protection Standard (8 CCR 5144) requires fit
testing for: ANS >>> Correct Answer: all tight-fitting respirators
EPA is the federal government agency that controls the disposal of solid
waste. Which of the following California State agencies also controls the
disposal of solid waste? ANS >>> Correct Answer: DTSC
,When performing abatement on the outside of a building, one layer of
plastic on ground should extend feet beyond the perimeter of working
surface? ANS >>> Correct Answer: 10
The HUD Guidelines specifically prohibits which of the following
activities: ANS >>> Correct Answer: Lead burning
According to the HUD Guidelines, heat guns should be used at
temperatures below: ANS >>> Correct Answer: 1100°F
The chemical symbol for lead is: ANS >>> Correct Answer: Pb
Subsection (e) of the Cal/OSHA Construction Standard for lead requires
the employer to reduce or maintain employee exposure at or below the
PEL utilizing: ANS >>> Correct Answer. A written compliance program,
mechanical ventilation, administrative controls, and engineering and
work practiced controls
Effective August 14, 2009 CPSC reduced the allowable lead content for
paint and similar 0.06% surface-coating materials for consumer use that
contain lead or lead compounds from (600 ppm) to parts per million,
based on a dried paint film. ANS >>> Correct Answer: 90
Methylene chloride is a common chemical used in paint strippers.
According to the text: ANS >>> Correct Answer: Methylene chloride is not
recommended on HUD projects
, Which of the following symptoms in a worker would indicate a possible
elevated blood lead level (BLL): ANS >>> Correct Answer: Joint or muscle
aches
Which of the following statements is true concerning "chelation"?
A. Chelation can be used to keep employee blood lead levels low so
they can remain working on lead jobs.
B. Chelation can only be administered by a licensed physician.
C. Chelation can only be administered by your employer with the
permission of a licensed physician.
D. Chelation is a type of electrode-shock therapy. ANS >>> Correct
Answer: Chelation can only be administered by a licensed physician.
When performing an interior abatement on walls where lead-based
paint is already in damaged condition it would be important to: ANS >>>
Correct Answer:
Perform some pre-cleaning of interior lead dust and debris before
placing plastic drop sheeting on floors
Which of the following CDPH Certified individuals can perform
clearance of an abatement area? ANS >>> Correct Answer: A Project
Monitor